background image

 

Manual

 

according to regulation DIN 82079

 

Version 10.19 

Date: 14.10.2019 

Name: Manual_VARIO-MA

 

 

GIEBEL FilTec GmbH • We

www.giebel-adsorber.de

 

 Email 

[email protected]

 

 Tel +49 (0) 7946 944401-0 

 

2/9 

Section 3: 

Structure and materials 

 
Adsorber part MA 

 

adsorber part 

DV 301-MA  
DV 321-MA 

adsorber part 

DV 311-MA 
DV 331-MA  
DV 511-MA  
DV 531-MA 
DV 561-MA  
DV 791-MA 

Use of the 

one-way 

returnable 

housing material 

Aluminium 

adsorbent 

Silica gel, activated carbon filter disc 

particulate filters 

Folded filter element with 3 µm separation efficiency 

seal material 

FKM / EPDM 

operating temperature 

-40°C - +80°C 

 

 

 

Mounting part MA 

 

receiving part 

DV 3-MA,DV 5-MA 

connection 

customs 

housing material 

Aluminium 

seal material 

NBR/FKM 

 

Section 4: 

Technical Data 

 

VARIO MA-D 

 

 

 

 

 

  

DV 300-MA 

DV 320-MA 

Total weight [kg] 

3,0 

3,8 

Adsorbent [kg] 

0,9 

1,3 

Height [mm] 

300 

400 

Housing diameter [mm] 

110 

110 

Insertion diameter [mm] 

150 

150 

connection 

G 1" STS 

(SW36) 

G 1" STS (SW36) 

Valves [IN-OUT] 

1-1 

1-1 

 

 

 

 

 

VARIO MA-R 

 

 

 

  

DV 310-MA 

DV 330-MA 

DV 510-MA 

DV 530-MA 

DV 560-MA 

DV 790-MA 

Total weight [kg] 

3,0 

3,9 

8,7 

11,0 

13,8 

16,5 

Adsorbent [kg] 

0,9 

1,4 

4,2 

5,4 

7,5 

9,6 

Height [mm] 

310 

410 

340 

440 

540 

640 

Housing diameter [mm] 

110 

110 

150 

150 

150 

190 

Insertion diameter [mm] 

150 

150 

180 

180 

180 

220 

connection 

G 1" STS (SW36) 

G 1" STS (SW36) 

G 1" STS (SW36) 

G 1" STS (SW36) 

G 1" STS (SW36) 

G 1" STS (SW36) 

Valves [IN-OUT] 

1-1 

1-1 

2-2 

2-2 

2-2 

3-3 

Summary of Contents for DV 310-MA

Page 1: ...lTec GmbH Carl Zeiss Str 5DE 74626 Bretzfeld Schwabbach Phone 49 0 7946 944401 0 Fax 49 0 7946 944401 29 E mail info giebel adsorber de Section 2 Adsorber overview DV 300 MA DV 320 MA DV 310 MA DV 330 MA DV 510 MA DV 530 MA DV 560 MA DV 790 MA Materials used Aluminium acrylonitrile butadiene rubber NBR activated carbon moulded carbon Silica gel amorphous silicon dioxide REACH notice No ingredients...

Page 2: ...perature 40 C 80 C Mounting part MA receiving part DV 3 MA DV 5 MA connection customs housing material Aluminium seal material NBR FKM Section 4 Technical Data VARIO MA D DV 300 MA DV 320 MA Total weight kg 3 0 3 8 Adsorbent kg 0 9 1 3 Height mm 300 400 Housing diameter mm 110 110 Insertion diameter mm 150 150 connection G 1 STS SW36 G 1 STS SW36 Valves IN OUT 1 1 1 1 VARIO MA R DV 310 MA DV 330 M...

Page 3: ...the system 2 Remove the adsorber part by opening the closing clamps 3 Open the cover and remove it from the adsorber part 4 Remove the seal in the cover and replace it with a new one 5 Remove the activated charcoal disc and empty the desiccant 6 Pull out the dust filter insert 7 Remove the lower foam disk as well 8 Insert new foam disk 9 Insert a new dust filter insert and then Fill with fresh des...

Page 4: ...gel Orange Green 4kg Order of spare parts For constant operational readiness of the adsorber and thus of the hydraulic unit or transmission make sure that there is always a spare parts package or a spare adsorber part in stock The time to complete saturation of the activated carbon by the adsorption of oil mist and thus also the service life of the adsorber depends on various factors Number and du...

Page 5: ...elevant legal regulations Metal and plastic parts should be separated according to type and disposed of The loaded drying agent Silicagel Orange can be disposed of in household waste Silicagel Orange is not classified as a hazardous substance according to European Union legislation Regulation EC No 1272 2008 According to the EC Directive 67 548 EEC or 1999 45 EC it is not subject to labelling Sili...

Page 6: ...irt particles Prefilter disc contaminated The filter unit can be clogged by dirt particles Oil film on the desiccant Oil particles collect in the pores of the silica gel Dirt particles can accumulate on the oil film and thus hinder the supply or exhaust air 2 Humid air flows into the system Porous seals Moist air can flow into the adsorber at the porous points This means that complete drying is no...

Page 7: ...the ambient temperature exceeds 80 C the incoming ambient air is only dried to a limited extent Adsorber housing is damaged Material resistance When selecting an adsorber the ambient and operating conditions should be taken into account Vibrations of the system Strong vibrations of the system can damage the adsorber 4 Thread from adsorber and accessories is damaged When installing the adsorber and...

Page 8: ...2 Check filter unit for impurities Check Remove the lid from the adsorber part and remove the activated charcoal disc Then empty the desiccant The filter unit can then be removed This must be checked for impurities and should be free of dirt for smooth operation Cycle Half yearly Action The filter unit is part of the spare parts package and should be replaced if there is contamination 3 Check pref...

Page 9: ... Action If the valves do not open and close replace the valve part with a new one to ensure full functionality 6 Optical control of the adsorber Check The adsorber valve part and adsorber part must be visually checked for damage Damage can occur due to various environmental or operating conditions Cycle Weekly Action If the adsorber is damaged replace the damaged part to ensure full functionality ...

Reviews: