OK!
NO!
Page
30
of
56
USE AND MAINTENANCE MANUAL
Code MUT 088
Rev. 1
WARNING: THE OPERATIONS FOR INSTALLATION MUST BE PERFORMED ONLY
BY PROFESSIONALLY QUALIFIED AND TRAINED STAFF, IN ACCORDANCE WITH
THE REGULATIONS IN FORCE.
WARNING: the adjustment must be made in safety conditions. With motorised
awnings there is a residual risk of crushing hands or head; therefore position
yourself on the outside of the awning, outside of the danger area (handling area).
In particular, to prevent risks of crushing/cutting, do not allow any parts of the
body to get between the mobile front of the awning and the fixed housings for the
structure. This is particularly important when the front is moving.
CHAPTER 7: INSTRUCTIONS FOR PROPER INSTALLATION
IMPORTANT: To properly set up the awning strictly follow the "INSTALLATION
INSTRUCTIONS" attached to this manual and included in the accessory box or in
another part of the package.
IMPORTANT: Before starting the limit switch adjustment, it is necessary to identify
the type of engine installed on the awning. The up and down indications depend on
the mounting to the right or left of the awning. Check the enabling of the thermal
switch after about 4-5 minutes.
IMPORTANT: after installation the declaration for proper installation must be
compiled by the installer (Sec. 14 par. 1).
CAUTION: If the installation includes several motors with remote control it is
advisable to power one motor at a time to avoid interference between them all.
During programming then power the 1st motor and program its remote control,
then disconnect the power supply to the 1st engine and power up the 2nd, repeat
the programming and so on.
NOTE: the minimum distance between 2 operators must be at least 30 cm so there
is no interference between them.
www.gibus.com
Summary of Contents for MED OPEN FLY
Page 2: ......