12
13
BL230-BL233
BL230-BL233
UK
UK
WARNINGS FOR THE USER
ELECTRICAL EQUIPMENT
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical
Service.
Periodically check functioning of the safety devices.
Any repairs must be carried out by specialised personnel using original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or
lacking experience and knowledge, unless appropriately instructed.
Do not access the circuit board for adjustments and/or maintenance.
CAUTION: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow these instructions in order to safeguard persons.
Keep this instruction booklet.
CAUTION:
It is important that an omnipolar magnetothermal switch, with a minimum contact opening of
3 mm, is fitted upstream of the control unit.
[
] [
]
Set up the electric system as shown
1a
1b
referring to the electric system regulations and other national
regulations in force. Keep the mains power connections clearly separated from the service connections
(photocells, sensitive frames, control devices, etc.).
The main components are:
À
Antenna: screened coaxial cable.
Á
Electronic equipment housing.
Â
Electric lock: cable with 2 cores - 1 mm² (2x1).
Ã
Key selector; cable with 3 cores - 0.5 mm² (3x0.5).
[
]
Ä
220 - 230 Vac Operators
1c
:
Power supply: cable w/ 4 cores - 1,5 mm² (4x1,5):
grey = COMMON; brown = POWER SUPPLY; black = POWER SUPPLY; yellow/green = EARTH
Å
Omnipolar magnetothermal switch with minimum contact opening of 3 mm.
220-230VAC/50-60 Hz power line to the device: cable with 3 cores - 1.5 mm² (3x1.5) (adhere to the
regulations in force).
Æ
220V Warning system - flashing light: cable with 2 cores - 1.5 mm² (2x1,5).
Ç
Shunt boxes.
È
Photocell transmitter: cable with 2 cores - 0.5 mm² (2x0.5).
É
Photocell receiver: cable with 4 cores - 0.5 mm² (4x0.5).
TECHNICAL DATA
BL230
Operator
BL233
220/230 V 50-60 Hz
150 W (~1000 N)
0.8 A (~1000 N)
1.5 A max
300 W max
140°C
non-reversible electromechanical with worm screw
12.5
m
F
3000 N (electronically adjustable)
-20°C +60°C
40% (~20°C)
500 mm
380 mm
IP 44
5 m
3.5 m
2 limit switches (open / close)
4 poles 1400 rpm
Type
Supply voltage
Power absorbed
Current absorbed
Max power absorbed
Max current absorbed
Electric motor
Breakaway capacitor
Max thrust / traction force
Operating temperature
Frequency of use
Effective travel
Protection class
Limit switches
Maximum gate length
Thermic
PRELIMINARY WARNINGS
Make sure that the gate structure conforms with current standards and that gate movement is linear and
friction free.
Preliminary checks:
• Make sure that the gate structure is sufficiently sturdy.
In any case, the actuator must operate on a reinforced point on the gate.
• Make sure that the gates move manually without effort over their entire travel.
[
]
• Make sure that gate opening and closing locator stops are installed
1a
.
• If the gate is not a new installation, check the wear status of the hinges and all components; repair or replace
defective or worn components.
The reliability and safety of the automation device are directly affected by the status of the gate structure.
Summary of Contents for BL230
Page 19: ...19 BL230 BL233 NOTE NOTES ...