16
UK
BE12
5 - ELECTRICAL CONNECTIONS: CONNECTORS
Description
CF1
0 VAC from transformer
FASTON
12 VAC from transformer
CF2
6 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Description
Terminal
Position
Signal
M1
Motor 1+
1
M1+
Motor 1-
2
M1-
Motor 2+
3
M2+
Motor 2-
4
M2-
+
12V
Electric lock power supply
5
EL+
- Electric lock power supply 12V
6
EL-
+ FLASHLIGHT power supply 12 VDC MAX 10W.
7
LAMP/SPIA
- FLASHLIGHT power supply 12 VDC MAX 10W.
8
LAMP/SPIA
M3
+12Vdc
MAX 10W
External accessory power supply
9
+ACC
External accessory power supply common
10
-ACC
11
5V
12
S1
13
COM
14
5V
15
S2
16
COM
M4
START input (N.O.).
17
START
PEDESTRIAN input (N.O.) (DIP 2_7)
18
PED
19
PHOTO 1
20
PHOTO 2
21
Accessory common.
22
COM
23
Accessory common.
COM
PHOTOCELL 1 input (N.C.). Input active only during closing. It stops and inverts the
motion, opening the gate completely. If the gate is closed, it does not affect its
functioning. If intercepted during pause, it reloads the pause time.
M2
PHOTOCELL 2 input (N.C.). Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
is freed. Upon release, motion always restarts in opening. If intercepted during pause, it
reloads the pause time.
STOP
SAFETY
Programmable INPUT (STOP – EDGE).
24
Unused imput.
25
IN2
IN1
Unused imput.
M5
M6
26
COM
27
ANT
+Battery 12V MAX 3Ah.
28
+BAT
-Battery 12V MAX 3Ah.
29
-BAT
Antenna braid input.
Antenna signal input.
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
UNUSED
17
UK
BE12
Description
Position
Value
Type
7 - PROTECTION FUSES
10A
F
F1
Protects battery power circuit.
3,15A
F
F2
Protects external accessories, electric lock and flashing light.
8A
F
F3
Protects the circuit board.
8 - WARNING LEDs
Description
Position
Colour
Signal
L1
GREEN
START
Comes on when the START control is activated from the terminal board or the receiver.
L2
GREEN
PED
Comes on when the PED control is activated from the terminal board or the receiver.
L3
RED
PHOTO1
Always on. Comes off when the contact of terminal PHOTO 1 is opened.
L4
RED
PHOTO2
Always on. Comes off when the contact of terminal PHOTO 2 is opened.
L5
RED
SAFETY
Always on. Comes off when the resistance value of terminal SAFETY is wrong.
L6
RED
RX
Always off, comes on when LEARN button is pressed.
L7
BLUE
INFO
0,2s ON 0,2 OFF
The control board is locked, it’s necessary to execute a new travel
learning procedure.
30s ON
The control board is in pre-learning phase, aftre pressing MEMO
button.
0,2s ON-4s OFF
During sleep time, the control board is set to work with MODO12-
MEKA BL12-ART3012 operator.
During sleep time, the control board is set to work with FLOOR812
operator.
0,2s ON - 0,2s OFF
0,2s ON - 4s OFF
2A
F
F4
Protects the transformer.
Summary of Contents for AS06260
Page 50: ...50 BE12 NOTE NOTES NOTES NOTAS ...