19
BE24
UK
10 - DIP SWITCH DIP2
ENCODER
2_4
TIME
ON
FUNCTIONING
OFF
changing this setting will
reset the control board and
a new learning cycle will be
required.
Anti crushing active.
-It is not active in the proximity of mechanical end stops.
-After anti crushing intervention the gate will reverse its movement for 1s, after a short
pause the movement will continue at slow speed.
-Subsequently to 3 consecutive anti crushing interventions the control board will
STOP and a user command will be required to start again the motion.
-Anti crushing is not active when working by time ( DIP2_4 = OFF)
2_5
Anti crushing disabled.
ON
ANTI
CRUSHING
OFF
2_6
ON
OFF
2_7
ON
OFF
2_8
ON
OFF
2_9
ON
OFF
2_10
ON
OFF
SPIA
/
FLASHING LIGHT
UNUSED
UNUSED
UNUSED
UNUSED
Terminal M2_7 and M2_8 work as WARNING LIGHT.
Terminal M2_7 and M2_8 work as FLASHING LIGHT.
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
DIP
Status
Function