SC230
SAFETY DEVICES (8K2) input.
After the intervention of the safety device, the control unit stops the motion, inverts it for
1 second and waits for a command.
If not used, make a bridge with terminal n°13, using a 8K2
Ω
resistance
Description
M1
M2
M3
Terminal
115 Vac power supply
1
Position
Signal
PHASE
115 Vac power supply
2
NEUTR
5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Flashing light output 115Vac 40W.
Slow flashing in opening, turned off in pause, fast flashing in closing.
PEDESTRIAN (N.A.) input
The pedestrian manoeuvre is made after the closing of this contact or by
the relay 2 of the plug-in two-channels receivers.
Operation in reply to a PEDESTRIAN command:
Ÿ
Gate closed
OPENS for 10 seconds (not adjustable).
→
Ÿ
During the opening
IRRELEVANT
→
Ÿ
Gate open
IRRELEVANT if the automatic reclosing is
→
enabled, otherwise CLOSES.
Ÿ
During the closing
OPENS completely.
→
PHOTOCELL (N.C.) input, see operation DIP SW1_5, Chap.8.
If not used,make a jumper with terminal n°13
3
8
5
10
LAMP
PED
PHOTO
START (N.A.) input. See DIP SW1_1 and SW1_2, Chap.8
Motor connection (opening)
Motor connection (closing)
SAFETY DEVICES / STOP (8K2) input, selectable by DIP SW1_10.
See description DIP SW1_10.
If not used, make a bridge with terminal n°13, using a 8K2 Ω resistance
COMMON INPUTS-OUTPUTS
4
9
6
11
7
12
13
START
OPEN
SAFETY
CLOSE
COM
M4
14
16
19
COM
IMP
15
17
18
24Vac
SPIA
+12Vdc
Power supply 24Vac external accessories (photocells, radio, etc) 8W Max
Power supply 24Vac for external safety devices tested, 8W Max .
Power supply 24Vac for external devices submitted to ENERGY SAVING.
See operation DIP SW1_4, Chap.8.
Inductive sensor input (black cable)
Inductive sensor power supply (brown cable)
WARNING LIGHT 24Vac 3W max. input
Slow flashing in opening, turned on fixed in pause, fast flashing in closing.
Motor common
COM
TEST
/
ENERGY
SAVING
SAFETY
/
STOP
COMMON INPUTS-OUTPUTS, COMMON MOTOR RPM SENSOR (BLUE CABLE).
UK
12
Summary of Contents for AS05710/115V
Page 26: ...SC230 NOTAS 26 ...
Page 27: ...SC230 NOTAS 27 ...