background image

24

GENERAL

The manufacturer warrants that, subject to verification of a warranty 

claim within the warranty period as described below, it will take the 

necessary corrective action to either repair or replace a water heater 

or component part which is determined to be defective in material 

or workmanship subject to the terms and conditions outlined in this 

document. Further, any replacement water heater or component part 

supplied under warranty will carry only the unexpired portion of the 

original water heater’s warranty. The number of replacement water 

heaters is limited to one (1) per original unit purchased. If due to 

some extremely unusual circumstance, a replacement water heater 

or component part is found by our inspection & testing department 

to be defective, another heater or component part will be supplied to 

fulfill the obligation of the warranty of the original heater.

THE INNER TANK

If the inner tank fails within SIX (6) years after the date of the original 

installation, a replacement water heater will be provided to the party 

from whom the unit was originally purchased. If the water heater is 

installed in other than a single family dwelling, the tank warranty is 

limited to ONE (1) year. If an exact replacement is not available, 

the manufacturer reserves the right to furnish a comparable model 

water heater; however, a surcharge will be applied for any addi

-

tional component(s) incorporated in the replacement water heater. 

The 

warranty 

reply card 

must 

be completed 

and 

sent back 

to the 

manufacturer 

within 

forty-five 

(45) 

days 

of 

the 

installation 

date. 

If 

said warranty card is not returned, the date indicated on the model 

serial plate will prevail. 

COMPONENT PARTS

If 

any 

component 

part 

is 

found 

to 

be 

defective 

within 

ONE 

(1) 

year 

from the date of original installation, provided said defective part is 

an in-house factory made piece or an original factory approved OEM 

piece, the manufacturer will furnish a replacement part after the 

receipt and testing of the part claimed to be defective. 

THIS WARRANTY WILL NOT APPLY

1)

 

To defects or malfunctions resulting from failure to properly 

install, 

operate, 

or 

maintain 

the 

unit 

in 

accordance 

with 

the 

print

-

ed instructions.

2)

 

If 

the 

installation 

does 

not 

conform 

to 

CSA 

&/or 

ETL 

Standards 

as well as any applicable national or local building codes.

3)

 

To any damage or failure caused by abuse, accident, fire, floods, 

freezing, or other acts of God.

4)

 

To 

any 

damage 

or 

failure 

caused 

by 

operating 

the 

heater 

without 

an approved 

pressure & temperature relief valve 

having been 

installed.

5)

 

To any damage or failure caused by operating the heater with an 

empty or partially empty inner tank or sediment build-up result

-

ing in dry firing of the heating elements.

6)

 

To any damage or failure caused by utilizing the heater in con

-

junction with any other energy saving device or other source(s) 

of 

energy 

not 

approved 

by 

the 

manufacturer; 

or 

for 

other 

than 

use with potable water without any additives such as salt, chlo

-

rine, or chemicals other than those added for the purpose of 

rendering the water fit to drink.

7)

 

To any damage or failure caused by the removal of the anode 

&/or by not assuring that there is a working anode in the tank at 

all times. All anodes must be checked at least once every two 

years & replaced if necessary

8)

 

To any damages or failure caused by having affixed to the 

heater any non-factory made or factory approved replacement 

part(s) such as elements, controls, dip-tubes, relief valves, etc...

9)

 

To 

any 

damage 

caused 

by 

not 

having 

the 

water 

heater 

installed 

adjacent to a free flowing drain in the event of water leakage. 

10)

 If 

the heater is 

operated 

at 

water 

temperatures 

exceeding 

the 

maximum setting of the operating &/or high limit control or the 

heater is not supplied with potable water, free to circulate at all 

times.

11)

 If the heater has experienced the effect of thermal expansion 

due to excessive pressure (exceeding 300PSI). The result of 

excessive pressure usually reverses the bottom of the inner tank 

and can occur with the addition of a pressure reducing valve &/

or a check valve in the municipal water supply system in a single 

family dwelling.

12)

 If the heater is installed outside of Canada or the United States.

SERVICE LABOUR RESPONSIBILITY

This warranty does not cover any labour expense for service, remov

-

al, or re-installation of a replacement heater. All such expenses are 

your responsibility.

SHIPPING COSTS

If a water heater or component part is deemed to be replaced, the 

manufacturer will pay the transportation costs of the replacement 

unit to a convenient authorized distributor or retailer as selected by 

us. You must pay any local cartage including the cost of returning 

the replaced item to the authorized distributor or retailer from whom 

the replacement is coming from.

HOW TO MAKE A CLAIM

Any claim for warranty service should be made to your contractor, 

wholesaler, or retailer from whom the water heater was purchased. 

In turn, said contractor, wholesaler, or retailer will contact the manu

-

facturer from whom they purchased the heater. If this procedure 

cannot be followed, contact any other local contractor, wholesaler, 

or retailer handling our water heaters. Also, for warranty information 

you may call the manufacturer’s customer service department at 

(514) 

645-8893 

or 

1-800-363-9354, 

option 

1. 

We 

suggest 

that 

prior 

to 

calling the 

factory, 

that 

you 

make 

sure 

to 

have 

the 

model 

number 

& serial number that is to be found on the outside casing of the 

heater. Proof of purchase showing the date, name, and place of the 

business from whom the water heater was purchased is essential 

to settle any warranty claim dispute over the length of the period 

of installation.

If an exact replacement is not available, a current model water 

heater or component part with comparable operating features will be 

provided by the manufacturer. If government regulations or industry 

standards require the replacement model water heater or compo

-

nent part to have features not found on the defective model water 

heater or component part, you will be charged the difference in price 

associated with these required features. If you pay the difference in 

price for these required features, you will receive a complete new 

Standard Basic Limited Warranty for the replacement water heater.

MISCELLANEOUS

No 

one is 

authorized 

to make 

any other warranties on 

the manu

-

facturer’s 

behalf. Any 

implied 

warranties 

of 

any 

nature 

offered 

by 

third 

party other 

than 

what 

is 

stated 

in 

this 

Standard 

Basic 

Limited Warranty will not be honoured. No claims for incidental or 

consequential damages (including damages from leakage) will be 

accepted. 

 If 

you do not 

return the 

warranty 

card, 

a proof 

of 

pur

-

chase showing the name, date, and location of the original source 

of purchase is a necessity to process a warranty claim. Failure to 

produce this documentation will result in the lesser or the warranty 

periods being offered. In order to avoid any confusion &/or disputes, 

we suggest that the warranty card be completed and mailed back no 

later than forty-five (45) days after installation.

EXTENDED WARRANTIES

For information on some premium quality residential gas & electric 

water heaters, contact your local licensed plumber, or look for them 

at selected retailers.

STANDARD BASIC LIMITED WARRANTY

ON RESIDENTIAL GAS WATER HEATERS

Summary of Contents for UG50-59

Page 1: ...sult causing property damage personal injury or death DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building From a neighbour s phone immediately call your gas supplier Follow the gas supplier s instructio...

Page 2: ...nt of an FVIR technology equipped water heater due to a flammable vapour shutdown is not covered under the terms of the Standard Basic Limited Warranty FVIR technology equipped with a flammable vapour sensor and the flame arrestor Safety Information 3 Installation Instructions 4 Location 4 Minimum Clearances 4 Combustion and Ventilation Air Supply 4 Requirements for Unconfined Spaces 5 Requirement...

Page 3: ... you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING Serious injury or death can occur if you do not follow the instructions immediately Serious injury or death can occur if you do not follow the instructions WARNING AVERTISSEMENT DANGER WARNING AVERTISSEMENT DANGER DO NOT use this water heater ...

Page 4: ...um Clearances The minimum clearances from combustible material for this water heater are Two 2 inches 5 1 cm from the sides and rear four 4 inches 10 2 cm from the front and eighteen 18 inches 45 7 cm from the top see Figure 1 Combustion and Ventilation Air Supply In order for the water heater to operate properly it must be supplied with an uninterrupted flow of clean combustion and ventilation ai...

Page 5: ...municates directly with the outdoors by means of a duct This duct shall be sized according to CAN CSA B149 1 and terminate within one 1 foot above and within two 2 feet horizontally from the burner level of the appliance having the largest input In U S A refer to ANSI Z223 1 NFPA 54 1 All Air From Inside the Building see Figure 4 The confined space shall be provided with two per manent openings co...

Page 6: ...ed If the design and free area is not known it may be assumed that wood louvers and grilles will allow 20 25 free area and metal louvers and grilles will allow 60 75 free area Louvers and grilles must be installed in the open position or interconnect ed with the water heater so that they are opened automatically during water heater operation Corrosive Atmospheres If this water heater is to be inst...

Page 7: ...ipe must be supported every three 3 feet 91 cm and vertical runs of vent pipe must be supported every five 5 feet 1 5 m According to the CAN CSA B149 Natural Gas and Propane Installation Code plastic vent systems installed in Canada must be certified to the STANDARD FOR TYPE BH GAS VENTING SYSTEMS ULC S636 Components of the certified vent system must not be interchanged with other vent systems or ...

Page 8: ...embly outlet 2 Cut pipe ends squarely removing all burrs and dirt 3 Dry fit the pipe fitting to be connected to make sure they fit properly 4 Clean the pipe fitting with the proper primer or cleaner 5 Apply a thin coat of cement to the fitting avoiding pud dling inside 6 Apply a liberal coat of cement to the vent pipe leaving no voids 7 QUICKLY assemble parts while cement is fluid If you wait too ...

Page 9: ...es 30 cm B Clearance to window or door that may be opened 12 inches 30 cm C Clearance to outside corner D Clearance to inside corner 3 feet 91 cm E Clearance to service regulator vent outlet 3 feet 91 cm 6 feet 1 82 m F Clearance to each side of center line extended above meter regulator assembly 3 feet 91 cm within a height 15 feet 4 57 m above the meter regulator assembly 3 feet 91 cm within a h...

Page 10: ...er heater Should this relief valve need to be replaced use only a new temperature and pressure relief valve Never install an old or existing relief valve as it may be damaged or inadequate for the working requirements of the new water heater This new relief valve must meet all local codes or at a minimum the requirements listed above Never install any other type of valve between the relief valve a...

Page 11: ...lumbing system Leave the faucets open until a constant flow of water is obtained 4 Check all of the plumbing connections to make sure there are no leaks Gas Connections DO NOT attempt to use this water heater with any gas other than the type of gas shown on the water heater rating plate Failure to follow this instruction can result in property damage per sonal injury or death The gas piping must b...

Page 12: ...a mixing valve must be installed in the potable side of the system This will temper the water and reduce the risk of scalding 6 If the incoming water line to the heater is equipped with a check valve water meter or pressure reducing valve an expansion tank must be installed in the system This will prevent weeping from the water heater relief valve and pre mature failure of the heater due to expans...

Page 13: ...rs la maison Pompe de circulation Évent Figure 11 Wiring Diagram Blower Unit M 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 High Limit Switch Vacuum Switch Red 1 2 3 1 2 3 Yellow Black Blue Orange White Green Black White Green White ON OFF Switch 1 2 3 4 5 6 4 3 2 1 Green White Orange Blue Black Yellow Red Gas Valve Hot Surface Igniter Flame Sensor Flammable Vapor Sensor Green Green Black Power Cord Yellow Gre...

Page 14: ...th a minimum rise of 1 4 inch per foot 21 mm m of run r Has all the vent piping been secured with the appropriate primer and solvent based cement r Has the venting been supported at the proper intervals r Have precautions been taken against condensation flowing into the power venter r Water Piping Is the dip tube installed in the cold water inlet r Has a temperature and pressure relief valve been ...

Page 15: ...eater immediately contact a qualified installer ser vice agency or the gas supplier DO NOT light this water heater if It is not full of water The gas supplied does not match the type listed on the rating plate Gasoline or other flammable vapours and liquids have been stored in the vicinity of the water heater Failure to follow these instructions can result in property damage personal injury or dea...

Page 16: ...The temperature indicators will now display the new temperature setting Press and release the COOLER but ton until you have reached the desired setting HOLDING DOWN THE BUTTON WILL NOT CONTINUE TO LOWER THE SETTING The button must be pressed and released for each tem perature change desired To increase the temperature press and release the HOTTER button once The temperature indicators will now dis...

Page 17: ... function of the FV sensor is to detect the presence of flammable vapours before they enter the combustion chamber and ignite If the FV sensor detects the presence of flammable vapours while the water heater is operating the gas control will switch to lock out mode and the water heater will shut down If the water heater is not operating when the flammable vapours are detected the control will swit...

Page 18: ...ll of the joints are properly sealed If any part of the venting system is damaged it must be replaced by a qualified service technician Anode rods Thiswaterheaterisequippedwithtwo 2 anoderodsthat are designed to prolong the life of the glass lined tank The anode rods are slowly consumed protecting the glass lined tank from corrosion The anode rods should be checked every two 2 years If more than h...

Page 19: ... cold water supply manual shut off valve is open before lighting the burner Getting Service for your Water Heater If you are having problems with your water heater follow these three easy steps 1 Consult the Troubleshooting Guide con tained in this manual see Page 21 It lists the most common problems experienced with your gas fired water heater The solutions you find listed may provide a quick and...

Page 20: ...oor 8 Resettable thermal switch 9 Drain valve 10 Overflow tube 11 Dip tube 12 2 Magnesium anode rods 13 Temperature pressure relief valve 14 Flue baffle 15 Complete blower assembly 16 High limit switch 17 Rubber transition fitting 18 Vacuum switch 19 Plastic lined di electric galvanized nipple 1 2 3 4 7 9 10 11 12 13 14 15 17 18 16 Complete blower assembly 19 5 Complete burner assembly 8 6 ...

Page 21: ... that it is located properly and free from contamination Reposition the flame sensor rod or lightly clean it with an abrasive cloth 3 The hot surface ignitor may not be positioned correctly Reposition as necessary 4 Check that the hot surface ignitor and flame sensor rod are wired correctly and in good work ing condition 5 Low voltage to the water heater Check and repair 7 The gas valve driver cir...

Page 22: ...a confined area Provide fresh air ventilation The burner flame is too high Insufficient secondary air Provide fresh air ventilation Orifice too large Replace with correct orifice Defective gas control valve Replace with new gas control valve The flame burns at the orifice Low gas pressure Check with gas utility company Defective gas control valve Replace with new gas control valve High operating c...

Page 23: ...ets demand Combustion odours Insufficient secondary air Provide fresh air ventilation Heater installed in a confined area Provide fresh air ventilation Flue clogged Clean Check for source of trouble and correct Smoking and carbon formation sooting Insufficient secondary air Provide fresh air ventilation Low gas pressure Check with gas utility company Burner flame yellow lazy Refer to The burner fl...

Page 24: ...a free flowing drain in the event of water leakage 10 If the heater is operated at water temperatures exceeding the maximum setting of the operating or high limit control or the heater is not supplied with potable water free to circulate at all times 11 If the heater has experienced the effect of thermal expansion due to excessive pressure exceeding 300PSI The result of excessive pressure usually ...