V. Operation Instruction 

   

1. Master Code 

        The master code comprises of a five-digit number and is used to access programming functions of the 

digital keypad and cannot be used for access i.e. It cannot be the same as other PINs. The default 
master code is set to 

12345

. Under normal operation the keypad is used for entering PIN to gain 

access. In the programming mode the keypad can be used to add/delete PINs, set relay strike time 
and other operation functions. 

2. Enter Programming Mode 

Press the master code twice (

12345 12345

) to enter programming mode (1 beep, Yellow LED flash). 

 

  3. Setting the Access Mode 

            The dual authentication feature allows the keypad to be programmed to grant access optionally with 

either Proximity Card only, or PIN or Proximity Card and PIN. 

      1. Enter programming mode  
            2. Press

0

   

            3. Press 

00

 (1 beep, Yellow LED stay on) for Proximity Card Only 

                Press 

01

 (1 beep, Yellow LED stay on) for Proximity Card or PIN 

                Press 

02 

(1 beep, Yellow LED stay on) for Proximity Card + PIN 

            4. Press 

#

 (1 beep) back to programming mode 

            5. Press 

#

 again (1 beep) back to standby mode (Yellow LED slow flash) 

   

  4. Setting the Relay Strike Time 

            The relay strike time determines the amount of time that the door remains unlocked after a valid 

proximity card or PIN is entered. 

NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay 

strike time to 0 second (relay set to toggle mode).

 

      1. Enter programming mode 
            2. Press

1

 for 

Relay 1

 (rapid Green LED flash)

 

 Enter 

00~99

 (1 beep, Green LED stay on) 

                Press

for

 Relay 2 

(rapid Red LED flash) 

 Enter

 00~99

 (1 beep, Red LED stay on) 

            3. Press 

#

 (1 beep) back to programming mode   

            4. Press 

again (1 beep) back to standby mode (Yellow LED slow flash) 

   

  5. Clear Memory of All Proximity Cards and PINs 

      1. Enter programming mode 
            2. Press

8

 (all 3 LEDs rapid flash) 

            3. Press 

88

 (all 3 LEDs stay on, 1 long beep indicating data successfully deleted) 

            4. Press 

#

 (1 beep) back to programming mode 

5. Press 

#

 again (1 beep) back to standby mode (slow Yellow LED flash) 

6. Reset Controller Parameter to Default Value 

   1. Enter programming 
   2. Press

8

 (all 3 LEDs rapid flash) 

   3. Press

 99

 (all 3 LEDs stay on, 1 long beep indicating data successfully deleted) 

      4. Press 

#

 (1 beep) back to programming mode 

      5. Press 

again (1 beep) back to standby mode (Yellow LED slow flash) 