L. Failure guidelines

No output voltage, 
buzzer sounds 
continuously

Incorrect output 
voltage

Cannot drive the 
load

1. Do not use when the battery is charging. 
2. Check the rated voltage of the battery 
and make sure that it is in the allowable 
range of the input voltage.

1. Turn on the power switch.
2. Check the cables and make sure they 
are tightly connected.

1. Use a true RMS multimeter to measure, 
such as model FLUKE 177/179.
2. Try to maintain the input voltage in the 
range of rated power
3. Change the battery of multimeter  then 
 test  again.

Reduce the load power, or turn on the 
appliance first, then turn on the inverter.

1. The switch is off.
2. The battery lead 
isn't connected well

1. RMS Multimeter 
measurement  error
2. The battery power 
of RMS Multimeter 
is low.
3. The input voltage 
is too high or too low.

1. Load power is too 
large, or the actual 
power of the 
appliance exceeds 
nominal power.
2. The starting power 
is larger than rated 
power (such as 
motor).

The internal inverter soft-start circuit will 
buffer starting the appliance.

Cut off the load and let it cool naturally for 
10 to 30 minutes. Restart it after it resumes 
to normal temperature. The load power is 
too large, reduce the total load power to the 
range of rated power. Avoid blocking the 
vent and improve the ventilation condition. 
Reduce the ambient temperature.

No output voltage

Low input DC voltage

High input DC 
voltage

Overload

Over temperature

Recharge or replace the battery

Reduce the load power.

M. WARRANTY

This product is designed using the most modern digital technology and under very 
strict quality control and testing guidelines. If, however, you feel this product is not 
performing as it should, please contact us: [email protected] directly.

We will do our best to resolve your concerns. If the product needs repair or 
replacement, make sure to keep your receipt/invoice, as that will need to be sent back 
along with the package. You have a full 18 months warranty from date of purchase.

Except as noted above, GIANDEL makes no warranty of any kind, express or implied, 
including without limitation the implied warranties of merchant ability and fitness for a 
particular purpose. In no event shall GIANDEL be liable for indirect, special or 
consequential damages. This warranty only applies to GIANDEL branded products. All 
other name brand products are warranted by and according to their respective 
manufacturer. 

The following situations will void warranty:

1. The box is distorted, damaged or changed, and interior parts damaged because of 
an exterior hit or drop not reported at time of delivery.
2. Connect the DC power incorrectly reversing the polarity. 
3. Dismantled or repaired the unit by an unauthorized person.
4. The unit was damaged by incorrect installation or operating method.

F o r   a d d i t i o n a l   p r o d u c t s ,  p l e a s e   v i s i t   o u r  w e b   s i t e :   w w w. g i a n d e l . c o m   o r  
www.giandel.com.au

-Modified sine wave inverters
-Pure sine wave inverters

T o  f i n d   o u t   w h e r e  t o   b u y   a n y  o f   o u r   p r o d u c t s ,  y o u   m a y   a l s o  e - m a i l :  
[email protected] .

Remote control interface 

AC output socket

AC output terminal

Power ON/OFF switch

Remote control interface 

AC output socket

AC output terminal

Power ON/OFF switch

Reviews: