Specifications
Model
Rated input Voltage
Continuous Power
Peak Power
Input Voltage Range
Over Voltage Shutdown
Low Voltage Shutdown
Low Voltage Alarm
Output Voltage
Frequency
Wave form
Efficiency
Over load protection
Short Circuit protection
Display
USB
No load current
Cooling fan
Storage temperature
Size (L
W
H)
Weight
Over heat Protection
12VDC
3000W
6000W
9.8~16VDC
16VDC
9.8VDC
10.1VDC
24VDC
3000W
6000W
19.6~32VDC
32VDC
19.6VDC
20.2VDC
12VDC
4000W
8000W
9.8~16VDC
16VDC
9.8VDC
10.1VDC
24VDC
4000W
8000W
19.6~32VDC
32VDC
19.6VDC
20.2VDC
Operating Temperature
(Automatic Recovery/
Shutdown
)
PS-3000QBR
PS-4000QBR
100V /
110V /
120V /
220V /
230V /
240V
AC
10% (Refer to label)
50Hz /
60Hz
1Hz
Pure Sine Wave
About 90%
ºF
ºF
149 8
1500~1800W
2000~2400W
yes
LCD
5VDC
0~2.4A
2 MAX 2.4A
32-113
ºF
14~ 113
ºF
15
8
6.7 inch
20.16
8
6.7inch
15.5lbs / 7.03Kgs
21.85lbs / 9.91Kg
2A
1.2A
3A
1.5A
Thermal controlled cooling fan. It won't work till inverter
case reaches
104
ºF
only.
Remark
Due to the continuous improvement of products, the technical parameters
in this manual are subject to change without prior notice.
A. INTRODUCTION
The
GIANDEL
pure sine power inverter product line is used for back-up power. The
pure sine product line is ideal for sensitive equipment and provides clean power, which is
more efficient for back-up power applications. The power inverter transforms DC (direct
current) electricity into AC (alternating current) power that can be used for running a wide
variety of tools and appliances. This inverter is perfect for providing mobile power in cars,
boats and work trucks. The inverter can also be utilized as a back-up source of electricity
in the event of an electrical failure or for several off-grid applications such as camping or
in your RV.
Please read this instruction manual carefully and make sure your inverter is installed
properly before using.
B. WARNING AND SAFETY
1. Read the manual before connecting this inverter and keep it for future reference.
2. Do not put the inverter under direct sun light or near a heating source.
3. The case of inverter will get hot when used. Do not allow flammable materials to contact
the inverter, such as clothing, sleeping bags, carpet or any other flammable materials.
The heat from the inverter can damage these items.
4. The power inverter is designed to be used with a negative ground electrical system!
Don't use with positive ground electrical systems (the majority of modern automobiles,
RVs, trucks and boats are negative ground).
5. Do not disassemble the unit: it may cause fire or electric shock.
6. This device should only be serviced by a qualified technician. This item does not have
any serviceable parts.
7. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and
refrigerator enclosures during installation.
8. Do not operate the inverter if under the influence of alcohol or drugs. Read warning
labels on prescriptions to determine if your judgement or reflexes are impaired while
taking drugs. If there is any doubt, do not operate the inverter.
9. People with pacemakers should consult their physician(s) before using this product.
Electromagnetic fields in close proximity to a pacemaker could cause interference to or
failure of the pacemaker.
10. Keep the inverter well-ventilated. Do not place any objects on top of or next to the
inverter or allow anything to cover the cooling fans; doing so can cause the inverter to
overheat, causing a potential fire hazard and/or damage to the inverter. Leave
adequate ventilation space underneath the inverter as well; thick carpets or rugs can
obstruct air flow, causing the inverter to overheat.
11. Avoid unintentional starting. Be sure the switch is in the OFF position when not in use
and before plugging in any appliance.
12. Keep inverter away from children. Don't install the inverter where it is accessible to
children.
13. The power inverter will output the same AC power as utility power, please treat the AC
outlets as carefully as you would your home AC outlets. Do not put anything other than
an electrical appliance into the output terminal. It may cause shock or fire.
Remote control interface
AC output socket
AC output terminal
Power ON/OFF switch
Remote control interface
AC output socket
AC output terminal
Power ON/OFF switch