6.
Output socket
AC output voltage
Single socket
max output current
Single socket
max output power
110~120VAC
220~240VAC
220~240VAC
220~240VAC
15A
16A
13A
10A
1500W
3000W
2500W
2000W
220~240VAC
13A
2500W
c
battery
terminal. Connect Black (-) battery cable to Black (-) battery terminal. Alligator clamp
cables may be used but only to connect to the battery. Do not use clamps on inverter
terminals. Alligator clamps are not a permanent solution. You may see a spark during
connection.
Do not reverse the polarity.
This may damage the inverter and void
warranty.
Notice:
1) Please do all the safety precautions before connecting, and then check whether the
battery voltage comply with the input voltage of the inverter.
2) The cables must be big enough to bear current, or else the inverter can not power up
a big load because of voltage reduce caused by the small cross-sectional wire.
Refer to the below table to choose cables accordingly.
able to Black (-) inverter terminal. Connect Red (+) battery cable to Red (+)
Inverter Input
voltage
Rating power
Max current
of cable
Specification of wire
length
1m
12V
24V
1000W
1500W
2000W
2500W
3000W
4000W
5000W
1000W
1500W
2000W
2500W
3000W
4000W
5000W
100A
150A
200A
250A
300A
400A
500A
50A
75A
100A
125A
150A
200A
250A
2
6AWG(13.30mm)
2
4AWG(21.15mm)
2
3AWG(26.67mm)
2
2AWG(33.62mm)
2
1AWG(42.41mm)
2
0AWG(53.49mm)
2
00AWG(67.43mm)
2
9AWG(6.63mm)
2
7AWG(10.55mm)
2
6AWG(13.3 mm)
2
5AWG(16.77mm)
2
4AWG (21.15mm)
2
3AWG (26.67mm)
2
2AWG (33.62mm)
2
N
13.30mm
2
N
21.15mm
2
N
26.67mm
2
N
33.62mm
2
N
42.41mm
2
N
53.49mm
2
N
67.43mm
2
N
6.63mm
2
N
10.55mm
2
N
13.30mm
2
N
16.77mm
2
N
21.15mm
2
N
26.67mm
2
N
33.62mm
Specification of wire
length
1m
Specification of wire
length
N m
2
3AWG(26.67mm )
2
1AWG(42.41mm )
2
0AWG(53.49mm )
2
00AWG(67.43mm )
2
2
1AWG(84.82mm )
2
2
0AWG(107mm )
2
2
00AWG(135mm )
2
6AWG(13.3mm )
2
4AWG(21.15mm )
2
3AWG(26.67mm )
2
2AWG(33.62mm )
2
1AWG(42.41mm )
2
0AWG(53.49mm )
2
00AWG(67.43mm )
Notice:
1. The above table is only for your reference. In practice, the thick wire can be replaced by
two thin parallel wires if only the total section acreage of the wire meets the
requirements.
2. In high current, the input DC wire may produce voltage drop, therefore, the operating
voltage should be subject to the value on the terminals. If the voltage drop is too large,
it can increase the acreage of the section or reduce the length of the lead. The
recommended length of lead is less than 1m.
3. Connect cathode wire of the battery to the cathode terminal (black) on the back panel of
inverter and then connect the anode wire of the battery to the anode terminal (red) on
the inverter, and fix them.
Warnings:
1) Please wear eye patch and work clothes when working around the battery to avoid the
acid and corrosive objects harm your eyes and skin.
2) Prepare enough water and soap. In case the acid materials contact eyes or skin, clean
it by soap and water as soon as possible. If the acid materials spay to your eyes
accidentally, clean it by cold water immediately and then sent to hospital.
3) Do not put any combustible material in the location of installation for spark will result
when it is connected to the battery.
4) Keep good ventilation. The battery may produce a little inflammable gas when it works,
so keep away from the inverter and it is better to install them in different space.
5) Fix the connecting wire of the input DC, or it will result the over-reduction of the voltage
or over-temperature of the wire.
6) Reverse connection of the polarities or the short circuit will burn the fuse or result the
permanence damage of the internal elements of inverter.
7) Take away the metal accouterment, such as ring or watch, when installation to avoid
the short circuit.
8) Although there is over-voltage protection, it may also cause damage of the inverter if
the input voltage is too high.
3. Connection of the AC appliance
Put the power plug of the AC appliance load into the output AC receptacle ofthe inverter
directly.
Warnings:
1. Make sure that the switches of the inverter and appliance power are in OFF position
before connection.
2. Check the power cord. If it is damaged, it should be connected after replacement.
3. Each outlet of the inverter has a given current rating of the manufacturer. It shall not
exceed this value during use. Otherwise, the socket may be damaged by overheating
and may cause an electric shock. The maximum output power of a single socket is
shown in the following table:
Connection of big load
For the appliances with a load more than the limit of AC socket ,please connect to the
Hard wire Terminals(if have) ,make sure the ground terminal of inverter connected with
ground terminal of appliance.
Remote control interface
AC output socket
AC output terminal
Power ON/OFF switch
Remote control interface
AC output socket
AC output terminal
Power ON/OFF switch