The manufacturer:
Via Abetone Brennero, 177/B,
46025 Poggio Rusco (MN) ITALY
Declares that the products:
DCF180
Are in conformity with the following CEE Directives:
•
EMC Directive 2004/108/CE and subsequent amendments
and that the following standards have been applied:
•
EN61000-6-2, EN61000-6-3, EN60335-1
Date 10/01/08
GI.BI.DI. S.r.l.
CE Declaration of conformity
Managing Director
Oliviero Arosio
UK
DCF
4
DCF
5
UK
PLEASE READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH
THE INSTALLATION.
Thank you for choosing GI.BI.DI.
• Before proceeding with installation, fit a magnetothermal or differential switch with a maximum
• Make the connections referring to the following tables and to the attached screen-print. Be extremely
careful to connect in series all the devices that are connected to the same N.C. (normally closed) input,
and in parallel all the devices that share the same N.O. (normally open) input. Incorrect installation or
improper use of the product may compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the
original components and accessories suitable for the specific application are not used.
• After installation, always carefully check proper functioning of the system and the devices used.
• This instruction manual addresses persons qualified for installation of “live equipment”. Therefore, good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
WARNINGS
: This product has been tested in GI.BI.DI. verifying the perfect correspondence of the
characteristics to the current directive.
Gi.Bi.Di. S.r.l.
reserves the right to modify the technical data without prior notice depending on the product
development.
TECHNICAL SPECIFICATIONS
1A 24V
Transmitter / Receiver 35mA
-20 ÷ +60 °C
DCF180 / AU02000
54
IP
Model/Item
Range
Signal
Infrared frequency
Relay power
Receiver power
Absorption
Operating temperature
30 m (12 m, external)
Impulse signal, unmodulated
2 Khz
12/24 V DC/AC
DISPOSAL
: GI.BI.DI. advises recycling the plastic components and to dispose of them at
special authorised centres for electronic components thus protecting the environment
from polluting substances.
INSTALLATION
Make the connections as shown in
Fig. 1
(RX) and
Fig. 2
(TX). Secure and power the photocell
(12 - 24 V DC/AC. Cover the photocell with the front panel and secure it with the screws provided. Interrupt
the photocell beam several times to check proper relay response.
JUMPER FUNCTIONS:
J1 and J2 = The photocell is set up to operate in synchronised mode. In this mode, the photocells
will only work if powered with alternating current and with the jumpers J1 (TX) and J2 (RX)
closed.When making the connections, pay attention to the exact position of the cables A and B
(Fig. 3).
If the device is powered with direct current, the jumpers J1 and J2 must be open.
J3 (RX)
CLOSED = Standard operation
OPEN = Delayed operation, to be used in particular weather conditions (snow).
N.B.: Delayed operation must not be set with the synchronism.
J4 = A B: N.C. output contact
J4 = B C: N.O. output contact