background image

2

Dyna-Glo

TM

 Delux Operating Instructions and Parts Manual

For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST         www.ghpgroupinc.com

RMC-FA300DGD

Dyna-Glo

TM

Propane Construction Heater

CSA 2.14b-2009, ANS Z83.7b-2009.

MATERIALS, PAPER OR CARDBOARD, A SAFE 

DISTANCE AWAY FROM THE HEATER AS 

RECOMMENDED BY THE INSTRUCTIONS.

NEVER USE THE HEATER IN SPACES WHICH 

DO OR MAY CONTAIN VOLATILE OR 

AIRBORNE COMBUSTIBLES, OR PRODUCTS 

SUCH AS GASOLINE, SOLVENTS, PAINT 

THINNERS, DUST PARTICLES OR UNKNOWN 

CHEMICALS.

 

WARNING

This product and the fuels used to 

operate this product (liquid propane), 

and the products of combustion 

of such fuels, can expose you to 

chemicals including benzene, which 

is known to the State of California to 

cause cancer and reproductive harm. 

For more information go to  

www.p65Warnings.ca.gov 

 

WARNING

Using this heater in a 

residential garage 

requires that the heater is positioned   

so that it is protected against any possible 

damage by a moving vehicle, etc.  It must be 

positioned so that the base of the heater is 

no less than 18 in (450 mm) above the 

garage floor or 8 ft (2450 mm) in repair 

garages. The heater must be placed on a 

stable surface. Do not place it on a chair, 

ladder, etc.  Raising the heater will reduce 

BUT NOT eliminate the possibility of lighting 

the vapor of any flammable liquids which 

may be improperly stored or accidentally 

spilled. If the smell of gasoline is present, 

DO NOT operate this heater until the area 

has been properly ventilated.

WARNING

Not for home or rec-
reational vehicle use.

The heater is designed and approved 
for use as a construction heater 
under ANS Z83.7 CSA 2.14. It is hard 
to anticipate every use which may 
be made of this heater. CHECK WITH 
YOUR   LOCAL FIRE SAFETY AUTHORITY 
IF YOU HAVE QUESTIONS ABOUT 
APPLICATIONS.
Other standards govern the use of fuel 
gases and heat producing products in 

specific applications.
Your local authority can advise you 
about these.
IMPORTANT: READ THIS USER’S 
MANUAL CAREFULLY AND 
COMPLETELY BEFORE TRYING TO 
OPERATE OR SERVICE THIS HEATER. 
IMPROPER USE OF THIS HEATER CAN 
CAUSE SERIOUS INJURY OR DEATH 
FROM FIRE, EXPLOSION AND CARBON 
MONOXIDE POISONING.
This is a direct-fired forced air 
construction heater for either indoor 
construction or outdoor use. Its 
intended use is primarily the temporary 
heating of buildings or structures under 
construction, alteration or repair. All 
the products of combustion generated 
by the heater are forced through the 
heater and released into the area 
being heated. This heater operates 
at approximately 98%+ combustion 
efficiency but still produces a small 
amount of carbon monoxide. Humans 
can tolerate small amounts of carbon 
monoxide for short periods. Carbon 
monoxide can build up in a heated 
space and failure to provide adequate 
ventilation could result in poisoning or 
death.

IMPORTANT SAFETY INFORMATION

–  Children should be carefully 

supervised, when they are in the area.

–  Always maintain proper clearance 

from combustible materials. Minimum 

clearance from  combustibles: 

Side - 24” (61 cm); Top - 72” (180 

cm); Front - 96” (240 cm). Floor - 

combustible. Not for use on finished 

floors.

–  Heater must be placed on level and 

stable surface.

–  Never place anything including clothes 

or other flammable items on the 

heater.

–  The appliance area shall be kept clear 

and free from combustible materials, 

gasoline and other flammable vapours 

and liquids.

–  Do not modify or operate a heater 

which has been modified.

–  Adequate clearance for accessibility 

and for combustion & ventilation air 

supply must be maintained at all times 

when the heater is operating.

–  Service and repair should be done by 

a qualified service person. The heater 

should be inspected before each use 

and at least annually by a qualified 

person. More frequent cleaning may 

be required as necessary. Do not 

service while hot or operating.

–  Never connect heater to an 

unregulated gas supply.

–  The heater is shipped from the factory 

for LP(Propane) gas. This heater is 

for use with propane gas only, do 

not convert heater to any other gas. 

Installation must conform to local 

codes or, in the absence of local codes, 

with the standard for the Storage and 

Handling of Liquefied Petroleum Gases  

ANSI/NFPA 58 and the Natural Gas and 

Propane Installation Code CSA B149.1

–  The minimum and maximum inlet 

pressures to the regulator from the 

gas tank are 5 psi and bottle pressure, 

respectively. Use only the regulator 

& hose assembly provided with the 

heater. Inspect the regulator/hose 

assembly prior to each use of the 

heater. If there is excessive abrasion 

or wear, or hose is cut, replace with 

regulator/hose assembly listed on the 

parts list prior to using this heater.

–  Gas supply connections should be 

checked using a 50/50 solution of 

liquid dish soap and never use a flame 

to check for gas leaks.

–  The electrical connection & grounding 

must comply with National Electrical 

Code. ANSI/NFPA 70 or in Canada CSA 

C22.1, Canadian Electrical Code, Part 1. 

Use only a properly grounded three (3) 

prong receptacle.

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Summary of Contents for Dyna-Glo Delux Series

Page 1: ...ROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM THE HZARARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL LABELS ETCETERA CONTACT THE MANUFA...

Page 2: ...of combustion generated by the heater are forced through the heater and released into the area being heated This heater operates at approximately 98 combustion efficiency but still produces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result i...

Page 3: ...r assembly runs from the propane supply to the heater itself After the gas runs through the hose and regulator it passes through the solenoid valve and out the nozzle into the combustion chamber AIR SYSTEM The internal motor turns the fan which pushes air around and through the combustion chamber Here the air is heated and provides a constant stream of warmth IGNITION SYSTEM The spark module sends...

Page 4: ... ghpgroupinc com Dyna GloTM Figure 4 Hose and Inlet Connector Hose Inlet Connector Installation Review and under stand all of the warnings in the Safety Information Section on pages 1 3 They are required to operate this heater safely Follow all local and state codes when operating this heater After installing all gas piping and making the proper connections be sure to check for leaks Apply a 50 50...

Page 5: ...hey are open Check the fuel level in the propane tanks If the level is too low replace the tank with a full one If heater still does not restart contact your nearest Service Center Maintenance Do not attempt to service the heater while it is hot operating or plugged in Severe burns or electrical shock can occur 1 Be sure to inspect the heater before each use Check for leaks using the method descri...

Page 6: ...nal wiring as supplied with the heater must be replaced it must be replaced with type AWG105 C wire or its equivalent except as indicated Type SF2 200 SGI 250 C Green Chassis Ground Black Back Pressure Switch Figure 7 Fan Cross Section Fan Setscrew Motor Shaft Hub Figure 8 Wiring Diagram For Technical Support or Troubleshooting Call 1 877 447 4768 6 For Technical Support or Troubleshooting Call 1 ...

Page 7: ...27 28 32 29 31 30 33 34 35 36 38 39 42 37 40 41 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 24 23 22 12 20 14 13 15 16 17 18 19 21 7 9 10 11 8 26 For Technical Support or Troubleshooting Call 1 877 447 4768 ProFitterTM Dyna GloTM Operating Instructions and Parts Manual 7 For Technical Support or Troubleshooting Call 1 877 447 4768 8 30 am 4 30 pm CST www ghpgroupinc com Dyna GloTM Delux Operat...

Page 8: ...5 2 29 Clip 2301973 1 30 Screw 2000375 1 31 Nut 2000231 1 32 Capacitor 2201586 1 33 Bushing Strain Relief 2101633 1 34 Power Cord Assembly 2201163 1 35 Switch 2201549 1 36 Solenoid Valve 2315449 1 37 Screw 2001206 2 38 Connector Inlet 2315595 1 39 Fitting 2315596 1 40 Solenoid Valve Bracket 2315594 1 41 Screw 2000416 2 42 Nut 2000384 2 43 Back Pressure Switch 2201594 1 44 Base Lower 2315589 1 45 S...

Page 9: ...yna Glo TM Propane Construction Heater RMC FA300PF DG DGD Symptom Possible Cause s Corrective Action Fan does not turn when electrical connection is made Heater will not fire Heater quits while running 1 No electric power to heater 2 Fan blade contacts inside of heater housing 3 Fan blade s bent 4 Fan motor defective 1 No spark at igniter 2 Improper spark gap 3 Bad electrode 1 Internal temperature...

Page 10: ...rts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS W...

Page 11: ... Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem cont...

Page 12: ...ou can also register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here Tel 877 447 4768 www ghpgroupinc com GHP Group Inc 6440 W Howard St Niles IL 60714 3302 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 ...

Reviews: