GHM GREISINGER RS PRO 205-1444 Operating Manual Download Page 3

H61.0.RS.6C-04

 Operating Manual RS MH 3161-

… - ex 

page 3 of 14 

1  General Note 

Read this document carefully and get used to the operation of the device before you use it. Keep this 
document within easy reach near the device for consulting in case of doubt. 

Mounting, start-up, operating, maintenance and removing from operation must be done by qualified, 
specially trained staff that have carefully read and understood this manual before starting any work. 

The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended 
one, ignoring this manual, operating by unqualified staff as well as unauthorized modifications to the device. 
The manufacturer is not liable for any costs or damages incurred at the user or third parties because of the 
usage or application of this device, in particular in case of improper use of the device, misuse or malfunction 
of the connection or of the device.  
The manufacturer is not liable for misprints.  

2  Safety 

2.1  Intended Use 

The safety requirements (see below) have to be observed. 

The device must be used only according to its intended purpose and under suitable conditions. 

Use the device carefully and according to its technical data (do not throw it, strike it, …) 
Protect the device from dirt.   

2.2  Safety signs and symbols 

Warnings are labeled in this document with the followings signs: 

DANGER 

Caution!  

This symbol warns of imminent danger, death, serious injuries and 
significant damage to property at non-observance.

 

Caution!

  

This symbol indicates a potentially dangerous situation in explosion-
prone areas that can result in death or severe injuries if not avoided. 

Attention!  

This symbol warns of possible dangers or dangerous situations which 
can provoke damage to the device or environment at non-observance.

 

Note!   

This symbol point out processes which can indirectly influence 
operation or provoke unforeseen reactions at non-observance.

 

Summary of Contents for GREISINGER RS PRO 205-1444

Page 1: ...H61 0 RS 6C 04 Operating Manual EN RS MH 3161 002 ex RS Stock number 205 1446 RS MH 3161 13 ex RS Stock number 205 1444 device without case device in leather case ready for use in Ex Zone rspro com ...

Page 2: ...3 CONNECTIONS 7 4 4 POP UP CLIP 7 5 START OPERATION 8 6 CONFIGURATION 8 7 REMARKS TO SPECIAL FEATURES 8 7 1 POWER OFF TIME 8 8 OUTPUT 9 8 1 SERIAL INTERFACE 9 9 INPUT ADJUSTMENT 9 9 1 ZERO DISPLACEMENT SENSOR OFFS 9 9 2 SCALE CORRECTION SENSOR SCAL 9 10 PRESSURE CONNECTION 10 10 1 DEVICE TYPE WITH RELATIVE PRESSURE 10 11 ERROR AND SYSTEM MESSAGES 10 12 SPECIFICATION 11 13 RESHIPMENT AND DISPOSAL 1...

Page 3: ...of the device misuse or malfunction of the connection or of the device The manufacturer is not liable for misprints 2 Safety 2 1 Intended Use The safety requirements see below have to be observed The device must be used only according to its intended purpose and under suitable conditions Use the device carefully and according to its technical data do not throw it strike it Protect the device from ...

Page 4: ...s pressure sensor power supply unit interface etc connected to the device must be on the same potentials If this is not guaranteed you have to connect them for a potential equalisation 7 Ambient conditions Take care that the device is not exposed to environments that make the intrusion of humidity water conducting liquids or dust possible 8 DANGER Trouble free operation and reliability of the devi...

Page 5: ... safe device again you have to check for visible damages and control functionality before you put it to the leather bag 14 Any changes or repair of the device is not allowed Please return device to manufacturer for repair or maintenance 3 Product Specification 3 1 Scope of supply The scope of supply includes Measuring device with 9V battery Operation manual Leather case 3 2 Operation and maintenan...

Page 6: ...figuration menu Store Quit press short hold function the last measuring value will be held in the secondary display press again hides the value Please Note Activating deactivating tara clears the max min memories 1 Zero Point Adjustment If there is no pressure or zero pressure absolute applied to the pressure ports the device will display 0 If there is a permanent deviation and device is operated ...

Page 7: ...dling Pull at label open in order to swing open the pop up clip Pull at label open again to swing open the pop up clip further Pop up clip closed Pop up clip at position 90 Pop up clip at position 180 Function The device with a closed pop up clip can be plainly laid onto a table or attached to a belt etc The device with pop up clip at position 90 can be set up on a table etc The device with pop up...

Page 8: ... 11 91 Base address of interface OFFS refer to list below The offset of sensor will be displaced by this value to compensate for deviations in the probe or in the measuring device oFF Zero displacement inactive 0 00 SCAL 2 000 2 000 The measuring scale of sensor will be changed by this factor to compensate deviations of temperature probe or measuring device oFF Scale correction factor inactive 0 0...

Page 9: ...interface are always in the selected measurement unit mbar bar Supported functions Code Name Function Code Name Function 0 Read measurement value 200 Read min display range 3 Read system state 201 Read max display range 6 Read min memory 202 Read display range unit 7 Read max memory 204 Read display range decimal point 12 Read ID number 208 Read of channels 174 Clear min memory 214 Read scale adju...

Page 10: ...000 2000 mbar 2000 0 mbar 11 Error And System Messages Display Meaning What to do Low battery power device will only continue operation for a short period of time Replace battery Battery empty Replace battery Mains operation without battery wrong voltage Check power supply replace it when necessary No display or confused characters device does not react on keypress Battery empty Replace battery Ma...

Page 11: ...or 8 x 1 mm 6 mm inner tube Ø tubes at the top of device Display 2 four digit LCDs 12 4 mm high and 7 mm high for measuring values and for min max memories hold function etc as well as additional functional arrows Pushbuttons 6 membrane keys Output 3 5 mm audio plug stereo Interface Serial interface 3 5mm jack can be connected to USB or RS232 interface of a PC via electrically isolated interface a...

Page 12: ...t package for reshipment especially for fully functional devices Please make sure that the device is protected in the package by enough packing materials 13 2 Disposal instructions Batteries must not be disposed in the regular domestic waste but at the designated collecting points The device must not be disposed in the unsorted municipal waste Send the device directly to us sufficiently stamped if...

Page 13: ...H61 0 RS 6C 04 Operating Manual RS MH 3161 ex page 13 of 14 16 EC Type Examination Certificate ...

Page 14: ...page 14 of 14 Operating Manual RS MH 3161 ex H61 0 RS 6C 04 17 EU Declaration of conformity ...

Reviews: