GHM GREISINGER G 1114 Operating Manual Download Page 4

 

 

1 | About this documentation 

G 1114 

4 / 29 

B-H88.0.12.DB2-1.1

About this documentation 

1.1 

Foreword 

Read this document carefully and familiarise yourself with the operation of the product 
before you use it. Keep this document ready to hand and in the immediate vicinity of 
the product so that it is available to the personnel/user for reference at all times in 
case of doubt. 
The product was developed according to the state of the art and fulfils the require-
ments of the applicable European and national Directives. All corresponding docu-
ments are available from the manufacturer. 
Only technically qualified persons are permitted to carry out commissioning, operation, 
maintenance and decommissioning. The qualified personnel must have carefully read 
and understood the operating manual before beginning any work. 

1.2 

Purpose of the document 

  This document describes the operation of the product.

  It provides important information for operating safely and efficiently with the prod-

uct.

  In addition to the quick reference guide with all relevant legal and safety content in 

hard copy, this document is a detailed reference option for the product.

1.3 

Legal notices 

The liability and warranty of the manufacturer for damages and consequential damag-
es are voided with misuse, disregarding this document, disregarding safety notices, 
assignment of inadequately qualified technical personnel and arbitrary modifications of 
the product. 
Only carry out the maintenance and service tasks on this product that are described in 
this documentation. In the process, adhere to the specified steps. For your own safety, 
only use original spare parts and accessories of the manufacturer. We assume no lia-
bility for the use of other products and resulting damage. 
This document is entrusted to the recipient for personal use only. Any impermissible 
transfer, duplication, translation into other languages or excerpts from this operating 
manual are prohibited. 
The manufacturer assumes no liability for print errors. 

1.4 

Correctness of content 

The contents of this document were checked for corrected and are subject to a con-
tinuous correction and updating process. This does not rule out potential errors. In the 
event that errors are discovered or in case of suggestions for improvement, please in-
form us immediately via the indicated contact information in order to help us make this 
document even more user-friendly. 

1.5 

Layout of this document 

Each chapter is explained at the beginning in the description. 

Summary of Contents for GREISINGER G 1114

Page 1: ...Operating manual G 1114 Vacuum meter barometer EN...

Page 2: ...sonnel 3 Description 3 1 Scope of delivery 3 2 Functional description 4 The product at a glance 4 1 The G 1114 4 2 Display elements 4 3 Operating elements 4 4 Connections 5 Operation 5 1 Commissioning...

Page 3: ...DB2 1 1 3 29 7 3 Calibration and adjustment service 8 Error and system messages 9 Disposal 10 Technical data 11 Spare parts and accessories 12 Ordering code 13 Service 13 1 Manufacturer 13 2 Repairs p...

Page 4: ...1 3 Legal notices The liability and warranty of the manufacturer for damages and consequential damag es are voided with misuse disregarding this document disregarding safety notices assignment of ina...

Page 5: ...ctions Shows an illustrative instruction or a configuration of the product Some instructions include a formula for a general understanding of a configuration programming or a setting of the product Re...

Page 6: ...unction and operational safety of the product can only be guaranteed if applicable safety precautions and the device specific safety instructions for this docu ment are observed If these notices are d...

Page 7: ...ndard many other connection options can be used easily and reliable with G 1 8 adapters The device must only be used under the conditions and for the purposes for which it was designed It must be hand...

Page 8: ...ity position independent sensor is the key component The operat ing elements are used to switch the product on and off and for configuration The following basic functions are also provided Min max val...

Page 9: ...ion of the battery status Unit display Display of the units or Min Max Hold information text Main display Measurement of the current pressure or value for min max hold Auxiliary display Measurement of...

Page 10: ...te display overhead display Function key Press briefly Freeze measurement Hold Return to measurement display Call up next parameter Long press 2s Start menu configuration appears in the dis play Close...

Page 11: ...he customer Gradient correc tion Calibration of the pressure sensor by the customer Nautical norm correction Nautical norm correction active Display air pres sure compensated to sea level The product...

Page 12: ...ress Single step Hold Fast change 2s 2s Product is switched off The menu is closed after the last parameter NOTE If the product is switched off without saving the configuration the last save value is...

Page 13: ...on Shut off time No automatic shut off Automatic shut off after a selected time in hours and minutes during which no buttons have been pressed Backlight Backlight deactivated Automatic shut off of the...

Page 14: ...tion a vacuum pump and a precise reference de vice are needed The zero point correction is used together with the gradient correction primarily for compensation of sensor deviations The entry takes pl...

Page 15: ...easured value offset Standard setting 0 0 i e no correction is made Sensor gradient correction The gradient of the measurement can be influenced with this factor factor is in Displayed value measured...

Page 16: ...e the device can be optimised for special measuring tasks After it is switched on the device starts up in standard measuring mode the relevant special function is started by pressing and holding the f...

Page 17: ...table hoses must be used for vacuum measurements silicon is suitable as a hose material due to the low rigidity 6 4 UT operation Universal hose connection for 6 x 1 mm 4 mm inside and 8 x 1 mm 6 mm in...

Page 18: ...suitable 6x1 mm PUR GDZ 03 Up to 9 bar rel vacuum suitable 6 5 QC6 operation Quick Connect for 6 mm hoses The practical quick change connection is only suitable for plastic hoses with 6 mm outer diame...

Page 19: ...quick couplers with nominal width 2 7 mm can be used 6 8 Replacement of pressure hoses The pressure connections are screwed into the product with a standard G 1 8 inch thread with end seal All common...

Page 20: ...ed and must be replaced However the device will still operate for a certain length of time If the display text appears in the main display the battery voltage is no longer ad equate for operation of t...

Page 21: ...c ognised worldwide These certificates offer high quality calibration and consistently high quality DAkkS calibration certificates can only be issued by accredited calibration laboratories which have...

Page 22: ...Battery depleted Error in the product Product is defective Replace battery Send in for repair Battery depleted Battery depleted Replace battery Battery depleted Battery depleted Replace battery Measu...

Page 23: ...The device must not be disposed of with household waste Return it to us freight pre paid We will then arrange for the proper and environmentally friendly disposal Private end users in Germany have the...

Page 24: ...f activated switches the product off automatically Additional functions Tare function V Averaging over 2 s 5 s 10 s Calibration Zero point and gradient adjustment Housing Break proof ABS housing Prote...

Page 25: ...legal regulations of the Member States 2014 30 EU EMC Directive 2011 65 EU RoHS Applied harmonised standards EN 61326 1 2013 Emission limits Class B Immunity according to Table 1 Additional error 1 F...

Page 26: ...device sleeve 475820 GCLIP1000 Self adhesive metal belt clip G 1 8 inch con nections GDZ UT GDZ QC6 GDZ ST6 GDZ MCM Hoses GDZ 01 GDZ 02 GDZ 03 GDZ 04 GDZ 31 601576 GDZ 18 Hose clamp for hoses with 6 m...

Page 27: ...ons for 6x1 mm 4 mm inside and 8x1 mm 6 mm inside hoses QC6 1 8 inch port incl quick fit connector for hose outer 6 mm ST6 1 8 inch port incl screw connector for hose outer 6 mm MCM 1 8 inch port incl...

Page 28: ...ofessionally and quickly in our service centre Monday to Thursday from 8 00 to 16 00 Friday from 8 00 to 13 00 GHM Messtechnik GmbH GHM GROUP Greisinger Hans Sachs Str 26 Service Centre 93128 Regensta...

Page 29: ...1 29 29 Post code 26000 26999 35000 36999 40000 69999 Email vertrieb west ghm messtechnik de Tel 49 2191 9672 0 Fax 49 2191 9672 40 Post code 70000 97999 Email vertrieb sued ghm messtechnik de Tel 49...

Reviews: