E40.0.1X.6C-07 

Operating Manual EB-

Logg 80K… 

page 4 of 14 

2.4  Safety guidelines 

This device has been designed and tested in accordance with the safety regulations for 
electronic devices. However, its trouble-free operation and reliability cannot be guaranteed 
unless the standard safety measures and special safety advises given in this manual will be 
adhered to when using the device. 

1. 

 

Install the displaying device according to the manufacturer's specifications and 
the valid standards and regulations. 

2. 

 

Modifications or repairs of the device may not be performed by the customer. 
For maintenance or repair the device must be sent to the manufacturer. 

3. 

 

Trouble-free operation and reliability of the device can only be guaranteed if the 
device is not subjected to any other climatic conditions than those stated under 
”Specification”. 

To protect the battery, the maximum permissible storage and transport 
temperature of the device is 70 °C

 

4. 

 

Trouble-free operation and reliability of the device can only be guaranteed if the 
device is not subjected to any other climatic conditions than those stated under 
“Specification”. 

5. 

 

When connecting the device to other devices (e.g. PC) the interconnection has to 
be designed most thoroughly as internal connections in third-party devices (e.g. 
connection GND with protective earth) may lead to undesired voltage potentials. 

6. 

 

If there is a risk whatsoever involved in running it, the device has to be switched 
off immediately and to be marked accordingly to avoid re-starting. 

Operator safety may be a risk if: 

  - there is visible damage to the device. 

  - the device is not working as specified. 

  - the device has been stored under unsuitable conditions for a longer time. 

In case of doubt, please return device to manufacturer for repair or maintenance. 

7. 

 

Do not use these products as safety or emergency stop devices or in any other 
application where failure of the product could result in personal injury or material 
damage. 
Failure to comply with these instructions could result in death or serious injury 
and material damage. 

8. 

 

This device must not be used at potentially explosive areas! 

9. 

 

This device must not be used at a patient for diagnostic or other medical pur-
pose. 

 
 

 

Summary of Contents for GREISINGER EB log 80 K SMB2

Page 1: ...Y Tel 49 9402 9383 0 info greisinger de www greisinger de Installation and operating manual Data logger for temperature from version 1 0 EB Logg 80K Please read these instructions carefully before use...

Page 2: ...ASYBus Configurator 8 7 Battery life time and recording period 8 8 Operating displays 9 8 1 Measured value display 9 8 2 Logger status messages 9 8 3 System messages 10 8 4 Alarm and error messages 10...

Page 3: ...ufacturer for damages and consequential damages are voided with misuse disregard of this operating manual assignment of inadequately qualified technical personnel and arbitrary modifications of the pr...

Page 4: ...nly be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification 5 When connecting the device to other devices e g PC the interconnection has to...

Page 5: ...he logger s delivery status The delivered logger is in a sleep mode that means nothing is displayed and the power consumption is at its minimum When there is a communication with the software for the...

Page 6: ...ng attached on the device EB Logg 80KH sensor tube made of stainless steel 5 mm ap prox 50 mm long approx 1 m silicone cable with anti buckling glanding to housing EB Logg 80KH SMB1 sensor tube made o...

Page 7: ...n again Delete min value Push button for about 5 seconds CLr is displayed and the min values of all measuring channels are deleted 6 2 Operating possibilities at the device logger operation Function P...

Page 8: ...s and alarm delay 1 activate the function logger stop via buttons disabled 1 Please note The alarm settings and the sea level correction can be only changed if the logger is stopped logger without log...

Page 9: ...atus messages are dis played STOP The logger recording has been stopped The logger memory is empty Note At this state the power consumption is at its minimum HOLD The logger recording has been halted...

Page 10: ...end the logger to the manufacturer for repair 8 4 Alarm and error messages The following messages correspond to a particular measuring channel and are dis played accordingly ALARM LOW The measured val...

Page 11: ...ttery life time depending on the chosen measuring cycle about 5 years at 15 minutes and nominal temperature Measured value memory 250 000 measuring values of each variable Measuring cycle 4 seconds to...

Page 12: ...n AFK The sensor socket is ESD endangered when the sensor is disconnected Disconnecting the sensor in EASYBus mode is not permitted Maximum sensor cable length 3m 10 Decommissioning reshipment and dis...

Page 13: ...The logger has still saved data Remedy Stop logger as recommended by the software delete data Problem A error message is displayed Error message Possible reason procedure remedy measuring range exceed...

Page 14: ...ck view on pins EASYBus not used Connection examples a General connection diagram for a relay with self induction recuperation diode b Connection information for GR 10 GNR 10 or GNR 232 A GND to be co...

Reviews: