 SERIAL

 

INTERFACE

 

AND

 

USB 

The HD3405.2 is fitted with an electrically isolated RS-232C and  USB2.0 serial interface

.  

The USB connection requires the previous installation of a driver in the instrument software. Install 
the driver 

before connecting the USB cable to the PC

 (please see the details on page 31).  

 
The instrument standard serial transmission parameters are: 

 

Baud rate   38400 baud 

 

Parity  

None 

 

N. bit 

 8 

 

Stop bit 

 1 

 

Protocol  

Xon/Xoff 

 
It is possible to change the RS232C serial port baud rate by setting the "

Baudrate

" parameter in the 

menu (please see page 9). The possible values are: 38400, 19200, 9600, 4800, 2400, 1200. The 
other transmission parameters are fixed. 
The USB 2.0 connection does not require the setting of parameters. 
 
The instruments are provided with a complete set of commands and data queries to be sent via the 
PC. 
 
All the commands transferred to the instrument must have the following structure: 

XYcr 

where: 

XY 

is the command code and 

cr

 is the Carriage Return  (ASCII 0D) 

 

Command 

Response 

Description 

P0 

Ping (locks the instrument keyboard for 70 seconds)

 

P1 

Unlocks the instrument keyboard 

 

S0 

AT  21.3       6.778 

Captured measurements (24 characters) AT = automatic temperature 
compensation, temperature, pH or mV.

 

G0 

Model HD3405 -2 

Instrument model

 

G1 

M=pH / Thermometer 

Model description

 

G2 

SN=12345678 

Instrument serial number

 

G3 Firm.Ver.=01-01 

Firmware 

version

 

G4 Firm.Date=2004/06/15 Firmware 

date

 

G5 

cal 0000/00/00 00:00:00 

Calibration date and time

 

G6 Probe=SICRAM 

Pt100 Type 

of probe connected to input

 

G7 

Probe SN=11119999 

Probe serial number

 

G8 

Probe cal.=2004/01/12 

Probe calibration date

 

GB 

User ID=0000000000000000 

User code (set with T2xxxxxxxxxxxxxxxx)

 

GC 

 

Print instrument's heading

 

K1 

PRINTOUT IMMEDIATE 
MODE 

Immediate printing of data 

K0  

Stop 

printing 

data 

K4 

Start logging data

 

K5 

Stop logging data

 

K7 & 

Enable 

REL 

function

 

K6 

Disable REL function

 

KP & 

Auto-power-off 

function=ENABLE

 

KQ & 

Auto-power-off 

function=DISABLE

 

LN 

&1999 

Number of free pages in the flash memory

 

LD 

PRINTOUT OF LOG 

Print data logged in flash

 

Summary of Contents for Delta OHM HD3405.2

Page 1: ...mation written in this manual and the instru ment that you have purchased We cannot entirely exclude errors in the manual for which we apologize The data figures and descriptions contained in this man...

Page 2: ...2 Temperature pH meter HD3405 2...

Page 3: ...ure from degrees Celsius to Fahrenheit 9 Function indicators 10 Key in the menu increases the current value 11 Line for symbols and comments 12 Main display line 13 ON OFF AUTO OFF key turns the instr...

Page 4: ...and the calibration sequence can be chosen from a list of 13 buffers The displayed data can be stored datalogger and can be transferred to PC or serial printer thanks to the multi standard serial port...

Page 5: ...input and sets the instrument ready for normal measurement MIN cm min s 2 3 m m k During turning on should no probes be connected the message NO_PRBE_ SER_NUM is displayed in the line for symbols for...

Page 6: ...ORING AND TRANSFERRING DATA TO A PERSONAL COMPUTER on page 29 2 Identifier of the sample being measured it is an automatically increased progressive number associated with the single PRINT function pr...

Page 7: ...on tinuous data transfer is started when the SERIAL key is pressed To end the recording LOG and continuous data transfer operations SERIAL with an interval greater than 0 press the same key again 5 Sl...

Page 8: ...value must be set at the actual solution temperature As an alternative the correct value according to temperature can be set in the calibration phase 12 RCD MODE Record mode the instrument captures a...

Page 9: ...ENTER The communication between instrument and PC or serial port printer only works if the instrument and PC baud rates are the same If the USB connection is used this parameter value is automatically...

Page 10: ...isabled The HD3405 2 can turn off during logging between one capture and the next the function is controlled by the Sleep_Mode_LOG parameter When the logging interval is less than one minute the loggi...

Page 11: ...arrows Confirm by pressing ENTER The DeltaLog9 software for PC will automatically set the baud rate value during connection If you are using a different program than DeltaLog9 be sure the baud rate i...

Page 12: ...ment if the tempera ture probe is not present it increases the temperature value for pH compensation Down Arrow When used in the menu it decreases the current variable value During measurement if the...

Page 13: ...ted by an electrode when immersed in a buffer solution at 7pH Generally oscillates between 20 mV Slope response of the electrode expressed in mV per pH units The theoretical electrode slope at 25 C is...

Page 14: ...turned on near the battery symbol if present On the print outs the MT indication is printed Instead if the probe is present the AT symbol is printed To manually change the compensation temperature pr...

Page 15: ...perature probe is available use another thermometer and enter the value manually as indicated in the paragraph Automatic or manual pH compensation 2 The electrode calibration mode is started by pressi...

Page 16: ...FR_1 BUFR_2 BUFR_3 parameters The 2 point calibration is possible using the sequence BUFR_1 BUFR_2 or BUFR_2 BUFR_3 or even BUFR_1 BUFR_3 The 3 point calibration is only possible us ing the exactly de...

Page 17: ...pH 25 C 4 01 pH 25 C C pH C pH C pH C pH 0 6 98 50 6 83 0 4 01 50 4 06 5 6 95 55 6 83 5 4 00 55 4 07 10 6 92 60 6 84 10 4 00 60 4 09 15 6 90 65 6 85 15 4 00 65 4 10 20 6 88 70 6 85 20 4 00 70 4 13 25...

Page 18: ...or is housed in the end part of the probe In the temperature measurement by penetration the probe tip must be inserted to a depth of at least 60mm the sensor is housed in the end part of the probe Whe...

Page 19: ...the 1 4 points on which the sensor wires must be welded The JP1 JP4 jumpers are in the center of the card These must be closed with a tin bead for some type of sensors 1 2 3 4 Pt100 3 fili Pt1000 Ni1...

Page 20: ...nnection of the 4 sensor to a DIN45326 connector Sensor 4 wire Pt100 can be welded directly to the DIN45326 female connector s pins without having to resort to the TP47 board The 4 wires of Pt100 must...

Page 21: ...ways very hard to perform It has high levels of uncertainty and depends on the ability of the operator 10 Temperature measurements on non metal surfaces usually require a great deal of time due to the...

Page 22: ...eplace the electrolyte with the KCL3M solution electrodes KP63 KP64 e KP90 or the PROTELYTE solution electrodes KP61 KP71 e KP80 Check that no air bubbles are present in the electrode tip and that it...

Page 23: ...the mV measurement is included in the 2 0 2 4V range UNDR Measurement overflow this appears when the mV measurement is in cluded in the 2 4 2 0V range LOG MEM FULL Memory full the instrument cannot s...

Page 24: ...on date month day hour minutes LOG In PROG logging in progress LOG MEM FULL memory full LOG_CLRD memory data cleared LOG_STOP logging complete LOG_STRT logging started MIN USE_UNIT_TO_ZERO SEC minutes...

Page 25: ...ent issues a long beep and turns off In this case replace the batteries or use the external power supply in order to turn the instrument back on In order to avoid data loss the logging session is ende...

Page 26: ...g Always use good quality leak proof alkaline batteries Sometimes on the market it is possi ble to find new batteries with an insufficient charge capacity INSTRUMENT STORAGE Instrument storage conditi...

Page 27: ...r where XY is the command code and cr is the Carriage Return ASCII 0D Command Response Description P0 Ping locks the instrument keyboard for 70 seconds P1 Unlocks the instrument keyboard S0 AT 21 3 6...

Page 28: ...in terval in the list 0 1 5 10 3600 seconds WC0 Setting SELF off WC1 Setting SELF on Command characters are exclusively upper case characters Once a correct command is entered the instrument responds...

Page 29: ...ssing the LOG key the instrument logs the first data and turns off 15 seconds before the next logging instant it turns on again to capture the new sample and then turns off The data stored in the memo...

Page 30: ...perator stops it by pressing SERIAL again See the description of the menu items on page 6 Connect the S print BT printer using cable HD2110CSP NOTES The print out is formatted across 24 columns Some k...

Page 31: ...ENU ENTER until the Baud Rate parameter select 38400 using the arrows confirm with ENTER The parameter remains in the memory until replacement of the batteries 4 Launch the DeltaLog9 application and p...

Page 32: ...ation could take a few minutes 17 The installation procedure is now complete the device will be detected on each new connec tion automatically In order to check if the entire operation was successful...

Page 33: ...egular functioning and operating security can be ensured only within the climatic conditions specified in the chapter TECHNICAL CHARACTERISTICS Do not use or store the instrument in ways and or places...

Page 34: ...off 20 A Mains cod SWD10 Output mains adapter 100 240Vac 12Vdc 1A Unit of measurement pH mV C F Security of memorized data Unlimited Time Date and time Schedule in real time Accuracy 1min month max de...

Page 35: ...d solutions automatically detected 25 C 1 679pH 2 000pH 4 000pH 4 008pH 4 010pH 6 860pH 6 865pH 7 000pH 7 413pH 7 648pH 9 180pH 9 210pH 10 010pH Measurement of mV by Instrument Measurement range 1999...

Page 36: ...H 5 100 C 3bar Glass body GEL filled 1 Teflon ring diaphragm Varnish Cosmetics Water emulsions Galvanic Creams Deionised water TRIS buffer Drinking water Fruit juices Solutions of low ionic content Ma...

Page 37: ...Drinking water Water emul sions Fruit juices Soap So lutions of low ionic content Preserved foods Water sus pensions Titration Titration in water solutions TRIS buffer Waste water Viscous samples Wine...

Page 38: ...400 C 0 25 C 50 C 350 C 0 4 C 350 C 400 C TP474C 0 Contact 50 C 400 C 0 3 C 50 C 350 C 0 4 C 350 C 400 C TP475A 0 Air 50 C 250 C 0 3 C 50 C 250 C TP472I 5 Immersion 50 C 400 C 0 3 C 50 C 350 C 0 4 C 3...

Page 39: ...aff and replaceable electrode holder Height max 380mm For 12mm electrodes HD22 3 Laboratory electrode holder with metal basis plate Flexible electrode holder for free positioning For 12mm probes TP47...

Page 40: ...eneral use not heavy duty GEL filled cable 1m with BNC glass body pH STANDARD SOLUTIONS HD8642 Standard solution 4 01pH 200cc HD8672 Standard solution 6 86pH 200cc HD8692 Standard solution 9 18pH 200c...

Page 41: ...m 4mm length 230mm Cable length 2 metres TP472I 5 Immersion probe sensor Pt100 Stem 6mm length 500 mm Cable length 2 me tres TP472I 10 Immersion probe sensor Pt100 Stem 6mm length 1 000mm Cable length...

Page 42: ...use 21 INSTRUMENT SIGNALS AND FAULTS 23 LOW BATTERY WARNING AND BATTERY REPLACEMENT 25 INSTRUMENT STORAGE 26 SERIAL INTERFACE AND USB 27 STORING AND TRANSFERRING DATA TO A PC 29 THE LOGGING FUNCTION...

Page 43: ...rding to the Directive UE 2002 96 EC the European users of electric and electronic devices are allowed to give back to the Distributor or Manufacturer the used device at the time of purchasing a new o...

Page 44: ...il pr sum d fectueux Dieser Garantieschein muss der Spedition beigelegt werden wenn das Ger t an das Kundendienstzent rum gesandt wird WICHTIG Die Garantie ist nur g ltig wenn dieser Abschnitt bis ins...

Reviews: