www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 12
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Pressing the switch (34), the
machine will not turn on.
Circuit switch to position “0”.
Power cable disconnected.
Press the power switch.
Connect the cable.
The brush does not rotate.
Function card damaged.
The touch sensor on the
handle is defective.
Brush motor damaged.
Brush rotation enabling
switch not pressed.
Replace.
Replace.
Replace.
Press the switch.
Aspirator does not work.
Function card damaged.
Intake motor damaged.
Suction unit switch not
pressed.
Recovery tank full.
Replace.
Replace.
Press the switch.
Empty, wash and clean the
tank and the probes.
The machine does not dry
well, leaving traces of water
on the floor.
Aspirator off.
Aspiration tube blocked.
Dirty wiper.
Recovery tank full.
Dirty water filter clogged.
Squeegee rubber blades
worn.
Start up the aspirator.
Check and if necessary
clean the aspiration tube
that connects the squeegee
to the recovery tank.
Clean the wiper.
Empty the recovery tank.
Clean the filter.
Replace or turn over the
squeegee rubber blades.
FRECCIA30 E 45_27lingue_2ed_04-2017.indd 12