www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 4
rything proceeding in reverse order.
DANGER:
Do not wash the appliance using jets of
water.
Periodic checks
Cleaning the detergent dispensing
nozzle
If you note that the detergent is not dispensed
evenly, clean the nozzle as described below:
- Remove the ring nut (34 Fig. 24).
- Remove the nozzle (35 Fig. 24) and clean
it with running water, if it is clogged use a
pin being careful not to distort the shape
of the nozzle.
- Reassemble all of the parts performing
these operations in the reverse order.
Cleaning the detergent suction filter
If you note that the detergent is not being
suctioned properly, check and clean the suc-
tion filter located inside the detergent tank.
- Using a screw driver, loosen the suction
cap (36 Fig. 25) and remove it from the
tank with the relative suction hose.
- Remove the filter (37 Fig. 25) and wash it
under running water; if it is too clogged it
should be replaced.
- Reassemble all of the parts performing
these operations in the reverse order.
Replacing the floor nozzle squeegee
(if present)
If when washing the floors the washing liquid
is not suctioned properly and the floor or car-
pet remains wet, check the condition of the
squeegee (38 Fig. 26).
If the blade is worn or damaged should be
replaced by releasing the blade support (39
Fig. 26) from the nozzle.
When replacing the new blade pay attention
to insert it properly into the mouthpiece, then
press until you hear the click coupling (Fig.
27).
SPARE PARTS
Slide nozzle body .................Code 7217519
Manuale M26_8050832_1ed_04-2017.indd 4
26/04/17 17:05