background image

 

G H A R I E N I   b e d s  

23 

  

 

                   

 

 

Ill. 20 

 
 
 
 

8 . 0

 

D r i v e   f a i l u r e s   /   r e m e d i e s  

 
 

 

Possible failures 

Remedies 

1. None of the 
motors work 

- No mains connection 
available 

- Check the mains 
connection 

- Mains connection lead 
defective 

- Replace the mains 
connection lead 

- Hand switch or motor 
connection plug not 
  plugged in correctly 

- Check that the plug 
connection is correct 

- Hand switch defective 

- Remove the hand 
switch 

- Fuse in the transformer 
defective 

- Replace it by a new 
fuse 

-Control box: system 
fully down 

- Replace 

 

 

2. An 
individual 
motor does 
not work 

- Motor connection plug 
not plugged in correctly 

- Check that the plug 
connection is correct 

- Hand switch defective 

- Remove the hand 
switch 

- Control box defective 

- Replace the control box 

- Motor connection lead 
or plug defective 

- Replace the motor lead 

- Motor defective 

- Replace the motor 

 

 

 
 
 
 
 
 
 
 

Type plate 

Summary of Contents for AMPHIBIA

Page 1: ...INSTRUCTIONS FOR USE AMPHIBIA TREATMENT BED Gharieni GmbH Gutenbergstra e 40 D 47443 Moers Tel 49 0 2841 88300 163 Fax 49 0 2841 88300 999 Service Hotline 49 0 2841 88300 40 E mail service gharieni de...

Page 2: ...7 2 0 GENERAL 7 2 1 BEFORE FIRST USE TRANSPORT UNPACKING 8 2 2 TRANSPORT AIDS 8 2 3 INSTALLATION CONNECTION 9 2 3 1 SPACE REQUIRED 10 2 4 PARTS ENCLOSED 10 2 5 POWER SUPPLY 10 3 0 THE AMPHIBIA BED 10...

Page 3: ...CESSORIES AYURVEDA MAT 19 6 0 OPTIONS 20 6 1 FOOT SWITCH 20 6 2 PROTECTIVE COVER WITH INSPECTION OPENINGS 20 6 3 AYURVEDA LINER 21 7 0 CLEANING AND MAINTENANCE 21 7 1 UPHOLSTERY CLEANING DISINFECTION...

Page 4: ...collection site for recycling electronic and electrical devices Do not remove this symbol from the product 1 0 S a f e t y i n s t r u c t i o n s Danger of electric current Make sure that the power o...

Page 5: ...original spare parts when making repairs 1 1 I n t e n d e d u s e The Gharieni MLW Amphibia is a versatile wellness treatment bed It can be used for cosmetic treatments or full body massages When th...

Page 6: ...alled for personal safety They must not be removed modified or by passed REMEDY ANY DEFECTS IMMEDIATELY OR HAVE THEM REMEDIED IMMEDIATELY 1 5 D a n g e r s d u e t o m e c h a n i c a l e n e r g y Be...

Page 7: ...environmental and waste disposal regulations of the country of use If you have any queries as regards disposal contact the local authorities responsible for waste disposal your dealer or Gharieni Gmb...

Page 8: ...n cover You can then lift the sleeve up and put it aside 2 2 T r a n s p o r t a i d s Do not hold the bed by its upper structure headrest backrest armrests or leg rest to lift it If subjected to a fo...

Page 9: ...ing the bed Caution collision of the inner shell with the outer shell After removing the carrying aids you must push the inner shell of the bed down again so that it rests on the steel structure of th...

Page 10: ...has the right voltage 230 V 3 0 T h e A m p h i b i a b e d The Amphibia bed can be used either with water or foam cushions point 3 1 The treatment bed has four electric adjusting motors see General i...

Page 11: ...sure that there is nothing between the parts of the bed which might get clamped 1 Height up Height down 2 Backrest up Backrest down 3 a Inclination up Inclination down b Store 4 Leg rest up Leg rest...

Page 12: ...cm This height enables the customer to comfortably sit or lie on the bed from the side The height adjustment is operated electrically Press the corresponding function key on the hand switch first row...

Page 13: ...ide and exert slight pressure to adjust the armrests downwards Pull the armrest up by hand to raise it override function This makes the bed extremely suitable for back massages ill 8 ill 8 4 5 S e a t...

Page 14: ...a bed has a special construction enabling runners to be extended in order to move the bed Proceed as follows First move the backrest up as described using the hand switch Remove the cover from under t...

Page 15: ...d be neither folded nor slipped down Risk of overheating no ok 5 1 F i l l i n g t h e w a t e r c u s h i o n s The water cushions can be removed individually and filled with water The cubic capacity...

Page 16: ...nnected Only use the heating mats in combination with the filled water cushions otherwise there is a risk of the lower heating mat overheating The heating cables must be run under the water cushions o...

Page 17: ...tch on the heating system The LEDs will flash The indicator flashes to indicate that the upper heating mat is ready for use This means that the heating mat is still off Step 2 Press the HMU upper heat...

Page 18: ...g is approx 28 C 6 LEDs lit up If all 10 of the LEDs have lit up the temperature setting is 32 C You can switch off the heating by means of the On Off button the LEDs will flash 5 6 D i s p l a y i n...

Page 19: ...ing to the same principle Ill 16 5 8 L i g h t i n g To set the lighting modes the control panel features one button for the upper and one for the lower lights ill 14 The following functions can be se...

Page 20: ...rest Observe the Up and Down indications in the picture for the directions of movement Three of the four memory positions M1 M2 and M3 can be called up by foot switch operation by pressing the foot op...

Page 21: ...th compressed air ill 14 approx 3 min by pressing the compressed air button Two valves which can be sealed to inflate or deflate the rim are located at the foot end ill 19b A hose is enclosed to conne...

Page 22: ...ntent less than 30 Since we make use of different forms of upholstery which may consist of different materials we need details of the specific situation in order to tell you whether a given disinfecta...

Page 23: ...ctly Check that the plug connection is correct Hand switch defective Remove the hand switch Fuse in the transformer defective Replace it by a new fuse Control box system fully down Replace 2 An indivi...

Page 24: ...output 24 V Fuse 3 A slow acting Activation duration drive 10 max 2 min 18 min Mains lead 2 5 metres straight black Hand switch Coiled cable grey IP category I Safety class against electric shock typ...

Page 25: ...2006 95 EG EMV Richtlinie 2004 108 EG Maschinenrichtlinie 2006 4 2 EG is produced in accordance with the requirement specified in Low Voltage Directive LVD 2006 95 EG electromagnetic compatibility 20...

Page 26: ...G H A R I E N I b e d s 26 1 0 0 A p p e n d i x 1...

Reviews: