GGM GUF Series Operation Manual Download Page 2

Thank you for purchasing a GGM product.
To ensure that you areusing this product correctly, make sure to first read this operation
manual thoroughly and familiarize yourself with allknowledge, safety information and 
precautions related tothe product. After you have read this operation manual, keep it 
at hand for reference whenneeded.

1. Safety precautions

In usingand operating the product, be sure to observe the following precautions. Failure to 
observe the precautions may result in electric shock, injury or fire. The following precautions
are very important and should be observed at all times.

 Do not use the product near explosive materials, combustible materials,

    flammable gas, corrosive materials, or anyplace where it may be splashed by
    water.
    Doing so may cause fire, electric shock or injury.

 Do not forcibly bend, pull or insert the motor lead wire.

    Doing so may cause fire or electric shock. 

 Do not move, install, connect or inspectthe product while an electric current

    is being applied. Be sure to only perform repair or installationwork after 
    cutting off the power supply. 
    Failure to do so may cause an electric shock.  

 H a v e   a   q u a l i f i e d   p e r s o n   w i t h   r e l e v a n t   k n o w l e d g e   i n s t a l l ,   c o n n e c t ,  

      o p e r a t e ,   c o n t r o l   a n d   c h e c k   t h e   p r o d u c t   f o r   f a i l u r e .    
        D o i n g   s o   m a y   c a u s e   f i r e ,   e l e c t r i c   s h o c k   o r   i n j u r y .

 After cutting off the power supply, allow a full minute to elapse before touchingthe

    output terminal. Failure to do so may cause an electric shock. 

 Be sure to cut off the power supply when the power failure protection device

    or overheating protection device (thermal protector) is triggered. 
    Failure to do so may cause injury when the product re-starts without warning.

 Install the bldc speed controller in the housing. 

   Ground the protective ground terminal when it is installed. 
   Failure to do so may cause an electric shock or injury.

Make sure thatthe AC power supply to the bldc speed controlleris at the rated 

    voltage. Failure to do so may cause a fire or product damage.

 Do not disassemble or modify the motor orthe speed controller.  Failure to do so

    may cause an electric shock or injury.

Ignoring thesewarnings may cause death
or serious injury.

2

Warning

Summary of Contents for GUF Series

Page 1: ...TION MANUAL Headquarters 1st Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea Tel 82 32 664 7790 Fax 82 32 611 7791 Attached research institute No 2 factory 180 Oksan ro Buche...

Page 2: ...t is being applied Be sure to only perform repair or installationwork after cutting off the power supply Failure to do so may cause an electric shock Have a qualified person with relevant knowledge in...

Page 3: ...0V three phase 200 240V Permissible range 10 50 60 Hz Permissible range 5 Rated Output Current Rated Torque Maximum Instantaneous Torque Rated Speed Speed Control Range Speed Regulation Power input Te...

Page 4: ...240V Three phase 200 240V F Series Unit Type GGM Co LTD 4 58 90 4 111 116 STAND BY RUN FWD REV GGM GGM CN3 SENSOR CN2 MOTOR CN4 I O CN1 200 240V 80 52 2 4 5 HOLE 98 2 4 5 THRU 2 M3 DP8 64 5 104 5 124...

Page 5: ...l buttons 5 Operation by external I O PLC etc Start Stop change of rotational direction multi level speed operation by external I O etc 6 Display indication load ratio actual speed etc Display of load...

Page 6: ...r turning on the alrarm code AL oP Pervention of operation at power on alarm is displayed and the do not operated motor Set the operation switch from RUN to STAND BY for release an alarm before use mo...

Page 7: ...Lock When pressing the S button the rotation speed is determined When the display is blinking the rotation speed has not set Can lock the operation by pressing the S button for more than 5 seconds in...

Page 8: ...P0 operation data 1 P1 operation data 2 P2 operation data 2 A rst Alarm reset E Err External alarm Output signals Can be used 3 functions out of SPd Speed output AL on Alarm output AL ov Overvoltage a...

Page 9: ...sistor output type programmable controller Attention For the Y0 Y1 and Y2 be sure to keep the current value at 100mA or less If the current exceeds this value connect the limiting resistor R 1 Limited...

Page 10: ...side 2 Select the operation data number suing the P0 P1 and P2 inputs 3 When the FWD or REV input is turned ON the motor will rotate 4 Switch the operation data number using the P0 P1 and P2 inputs 5...

Page 11: ...11 10 Setting and 7 segments display 10 1 Monitor mode...

Page 12: ...12 10 2 Input Output setting mode...

Page 13: ...10 3 Parameter setting mode 1page 13...

Page 14: ...10 3 Parameter setting mode 2page 14...

Page 15: ...10 3 Parameter setting mode 3page 15...

Page 16: ...10 3 Parameter setting mode 4page 16...

Page 17: ...or is calculated and input the conveyor speed can also be displayed When increasing the motor rotation speed using the external input the converted speed can be displayed After the power is turning on...

Page 18: ...on alarm External I O function External input function X0inputfunctionselection X1inputfunctionselection X2inputfunctionselection X3inputfunctionselection X4inputfunctionselection Externaloutputfuncti...

Page 19: ...gnable alternative input functions Description For every rotation of the motor 30 pulses are output SPEED RPM SPEED OUT Hz 60 Sec 30 pulses It is output when an alarm is generated Normally closed It i...

Page 20: ...T ERROR Stop input Check the power supply voltage If this alarm occurs during operation reduce the load or make the acceleration deceleration time longer Review the ambient temperature Check the wirin...