GFS Day Alarm Assembly Instructions Manual Download Page 8

GfS-Day Alarm

  

Art.-Nr.: 700 000/710 000/730 000/740 000/741000

8

MA_GfS-Tagalarm_0515_GB

GfS Day Alarm INOX  GfS Art. No 741 000 with cable reed contact – battery operated

TECHNICAL DATA 

Art.-Nr.: 741 000

1

2

3

4

5

6

7

8

9

10

external key switch

reed contact

External access control system

floating contact

external key switch

NO

NC

COM

24 V

GND

Key switch parallel to internal key switch

Battery operation

Basic functions of the GfS Day Alarm with battery operation are similar to 
those of mains operation. 

Differences

Relay operates in the opposite way (it is permanently deactivated, in case 
of an alarm it will be activated). While the GfS Day Alarm is activated the 
red LED is switched on for approx. 15 sec. Then the LED expires and the 
GfS Day Alarm operates in a stand by mode (while waiting for external 
signals). During the permanent opening mode the green LED flashes every 
60 sec. 

Batterie Control

only active when battery operated. Voltage is being measured after the red 
LED is switched-off and then every 12 hours. The green LED is triggered 
briefly (100ms) in order to put some load on the battery. In case that the 
battery supply is less than 7,5V the buzzer sounds briefly. Now the meas-
urement takes place every 60 sec. and triggers a brief alarm.

Operation in parallel

With mains supply it is also possible to use a battery in parallel (only with-
out integrated receiver). In case of power failure the GfS Day Alarm starts 
to be battery operated after 15 sec.  When the power failure is over the GfS 
DayAlarm operates automatically again with mains supply.

Summary of Contents for Day Alarm

Page 1: ...41000 A r t N r Art Nr 700000 730000 A r t N r GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 D 21079 Hamburg Tel 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online...

Page 2: ...n and red LED The battery operated GfS Day Alarm LC however does not integrate a flash light The GfS Day Alarm LC which integrates battery monitoring just operates in combination with cable reed conta...

Page 3: ...n and remove it Open the door and walk through Close the door again The red LED shines and the the GfS Day Alarm is activated again In case that nobody walks through the door the green LED shines for...

Page 4: ...rops out that means in case of an alarm COM and NC are closed in all other cases COM and NO are closed Jumper set Pos 1 2 After 3 minutes the sir ne is switched off automatically The flash light remai...

Page 5: ...e till the GfS Day Alarm is reset Pos 2 3 The siren and falsh light is permanently activated in case of an alarm Jumper 2 Pos 1 2 For cable reed contact Power plug GfS Art No 700 000 scope of delivery...

Page 6: ...n opened while the GfS Day Alarm is armed Buzzer resounds DIP 4 is OFF Flash light is activated Red LED flashes quickly 0 3 sec on 0 3 sec off Relay switches off COM and NC are connected Buzzer expire...

Page 7: ...ey switch parallel to internal key switch Clamp Functions 1 3 Floating relay 30 V 0 5 A max 4 8 12 V DC max 13 V 5 GND 6 7 Parallel to internal key switch To be connected with GND 7 8 External key swi...

Page 8: ...ched on for approx 15 sec Then the LED expires and the GfS Day Alarm operates in a stand by mode while waiting for external signals During the permanent opening mode the green LED flashes every 60 sec...

Page 9: ...t function No remote reed contact available Cable reed contact with 2m cable Max distance between reed contact and magnetic counter part between 5 to max 10mm Power supply 9 V block battery in the sco...

Page 10: ...lected transmitters without having to reset the receiver totally Push the program button for a minimum of 3 seconds The light signal blinks Operate the transmitter that shall be deleted This is confir...

Page 11: ...the operator Version GfS Day Alarm with external power supply GfS Art No 700 000 GfS Day Alarm battery operated GfS Art No 710 000 GfS Day Alarm with integrated power supply GfS Art No 730 000 GfS Day...

Page 12: ...ates correctly Pecularities of the building site All GfS Day Alarms are accessible The GfS Day Alarm has been tested and approved Version GfS Day Alarm with external power supply GfS Art No 700 000 Gf...

Page 13: ...Art Nr 700 000 710 000 730 000 740 000 741000 GfS Day Alarm 13 MA_GfS Tagalarm_0515_GB NOTES...

Page 14: ...rn back the key into the middle position and remove it Close the door or in case that the door is already closed wait for approx 15 sec The LED shines red the GfS Day Alarm is activated red LED shines...

Page 15: ...s max 1 sec 3x press each time max 1 sec flashes shines for approx 4 sec expires Deleting single senders Description Programming button LED Press programming buttom for at least 3 sec Operate the radi...

Page 16: ...GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 D 21079 Hamburg Tel 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online com...

Reviews: