Art.-Nr.: 700 000/710 000/730 000/740 000/741000
GfS-Day Alarm
5
MA_GfS-Tagalarm_0515_GB
GfS Day Alarm GfS Art. No 700 000/730 000 with cable reed contact – terminal diagram
TECHNICAL DATA
Art.-Nr.: 700 000/730 000
• Connection of external alarm devices by floating contact possible
• Resetting only with internal keyswitch
• Permanent opening
• Door-too-long-open-alarm
• External key switch for authorized use only (including protection
against tampering)
The relais is permanently pulled (power supply control). When an alarm is
triggered, the relais drops out, that means in case of an alarm COM and
NC are closed, in all other cases COM and NO are closed.
Jumper 1 set
Pos. 1-2: After 3 minutes the sirène is switched-off automatically.
The flash-light remains active till the GfS Day Alarm is reset.
Pos. 2-3: The siren and falsh light is permanently activated in case
of an alarm.
Jumper 2
Pos. 1-2 For cable reed contact
Power plug GfS Art. No. 700.000 (scope of delivery)
IN/PRI 230 V ~ 50 Hz 17 W
OUT/SEC 12 V DC 600 mA 7,2 VA
Intergrated power supply unit for mains supply
730.000 and 740.000 (scope of delivery)
IN/PRI 230 V ~ 50 Hz 17 W
OUT/SEC 12 V DC 600 mA 7,2 VA
Cable reed contact
with 2m cable
Max. distance between reed contact and magnetic counter part
between 5 to max. 10 mm.
Radio transmitter might be retrofit
1 2 3 4 5 6
3
2
1
5
9
8
4
7
6
floating contact
GND
external key switch
COM
reed contact
reed contact
+ 12 V DC
External access
control system
floating contact
external key switch
NC
NO
1
2
3
Jumper 1 Pos. 1–3
Jumper 2 Pos. 1–2
9
8
4
7
3
6
2
5
1
reed contact
floating contact
GND
external key switch
COM
reed contact
+ 12 V DC
external key switch
NC
NO
External access control system
floating contact