Important recommendations
0
Never interfere with the product when connected
to a power source;
0
Avoid direct contact with water;
0
Regularly check the state of the product;
0
Respect the current norms;
0
Wear protected glasses to avoid injury during the
drilling phase;
0
Chance the factory code;
General remarks
!
Radio
The materials and the technology used have made it
possible to create a system functioning on the 433,05 -
434,790 MHz frequency band, used by LPD equipments
and therefore subject to european radio and
electromagnetic compatibility regulations (CE).
!
Rolling Code
In order to guarantee your safety and the total
inviolability of the communication between transmitter
and receiver, the code sent out by the transmitter
changes every time the equipment is used and is
recognised by the receiver only, thanks to an
unfalsifiable code-setting calculation. The system thus
conceived avoids all risk of being recording or of the
code being copied (268 million combinations).
Composition of the receiver
See fig. 1 of the enclosed “Installation phases”
Item
Description
Q.ty
1
Receiver
1
2
Antenna wire
1
3
Assembly screws
4
4
Plugs
4
Characteristics
!
Receiver
Local oscillator freq.
6,6128 MHz
Power supply
12/24 Vac/dc
Modulation
AM/ASK - FM/FSK
Number of memorizable users 507
Number of relays
2
Type of output contact
1 NO, 1 NO/NC
Commutable power
24 VA
Maximum relay voltage
60 V
Absorbtion
95 mA (relay excited)
Housing protection
IP 40
Operating temperature
from -10°C to +55°C
Dimensions (Fig 1)
180x140x68mm
Weight
330gr
!
Transmitter
Frequency
433,92 MHz
Power supply
12 Vdc
Modulation
AM/ASK
Number of functions
2 or 4
Coding type
Rolling Code
Number of combinations
E.r.p.
100 - 200 µW
Absorbtion
18 mA
Range in open space with
receiver with antenna
100-200 meters
Operating temperature
-10°C to +55°C
Dimensions
82x48x16 mm
Weight
32gr
Battery type
Alkaline - 23A
Pag. 2
Receiver
Transmitter
EVR/R500 VR/TF2E 2 Channel
( AM/ASK) VR/TF4E 4 Channel
EVR/TMASTER 2 Channel MASTER
Compatibility
The receiver can operate correctly with the corresponding
transmitters according to following table:
Declaration of Conformity
Hereby, CDVI Wireless Spa, declares that the radio equipment
type EVR/R500 is in compliance with directive 2014/53/EU. The
full text of the EU declaration of conformity is available at the
following internet address: www.gfa-elektromaten.co.uk