background image

CAUTION!

Never connect 115 VAC or 230 VAC

 to rear power 

terminals. High voltage AC will damage instrument and 
void warranty.

CAUTION!

•  Remove power to unit 

before wiring input and 
output connections.

• Follow instructions 

carefully to avoid 
personal injury.

Signet 5500 Flow Monitor

English

Technical Notes:

•  To reduce the possibility of noise interference, isolate AC power lines from signal lines.
•  Maximum 4 to 20 mA loop impedance (sec. 6) is affected by the supply voltage.

1.  Power Connections

2.  Compatible Sensor Wiring

2000
2507
2536
2540
2100
2537
2551
2552

515
525

Open Collector  
Sensor 

Std. Sensor 

Freq. IN 

Sen. Pwr

Freq. IN  

Iso. Gnd 

Red

Black

Shield

Red

Black

Shield

Signet Sensors:

5500 
Termina

ls

= Double Insulated

= DC or AC power

Contents

 1.  Power Connections
  2.  Compatible Sensor Wiring
  3.  Sensor Pulse Output Connections
  4.  Auxiliary Pulse Output Connections
  5.  Totalizer Reset Connections
  6.  4 - 20 mA Current Output Connections
 7.  Relay Connections

 8.  Output Functions
 9.  Menu Functions
 10.  Parts  and Accessories
 11.  Speci

fi

 cations

 12.  Quick Reference Menu Parameters
 13.  Troubleshooting
 14.  Maintenance

Total 
reset 

AUX 

output 

PLS 

output 

Gnd 

 

Gnd 

Freq. IN 

Sen. Pwr

Freq. IN 

Iso. Gnd 

Std. Sensor 

        

  Patent No.  D376,328

     Flow 

Open Collector  
Sensor 

12-24 V 

10 W 

 

LISTED 
77CJ 

U L 

Total 
reset 

AUX 

output 

PLS 

output 

Gnd 

 

Gnd 

Freq. IN 

Sen. Pwr

Freq. IN 

Iso. Gnd 

Std. Sensor 

        

  Patent No.  D376,328

     Flow 

Open Collector  
Sensor 

12-24 V 

10 W 

 

LISTED 
77CJ 

U L 

1. 

2. 

3. 

Remove terminal blocks for easy wiring

*3-5500.090-1*

3-5500.090-1 Rev. 

01/12 English

 

12-24 V 

10 W 

 

12 - 24 VDC 

OR 

12 - 24 VAC 

5500 
Terminals

External power

supply

Summary of Contents for Signet 5500

Page 1: ...Double Insulated DC or AC power Contents 1 Power Connections 2 Compatible Sensor Wiring 3 Sensor Pulse Output Connections 4 Auxiliary Pulse Output Connections 5 Totalizer Reset Connections 6 4 20 mA...

Page 2: ...t PNP source input 5500 Terminals External power supply 28 VDC max Other instrument Gnd Input NPN sink input Gnd AUX output N 5500 Terminals Signal output Signal ground 3 28 VDC External power supply...

Page 3: ...wer is applied after the relay 2 setpoint is reached 6 4 to 20 mA Current Output Connections sec 8 4 4 20 mA 5500 Terminals 4 20 mA Fuse 1 8A Technical Notes 1 8 A fuse recommended customer supplied 4...

Page 4: ...nsor also displayed on totalizer To enable the totalizer function the operator must set the relay or auxiliary pulse volume setpoint to 1 0000 sec 9 2 H 9 2 L Totalizer function ideal for external cou...

Page 5: ...djustments ENTER OPTIONS sec 9 3 CALIBRATE sec 9 2 VIEW sec 9 1 2 seconds 5 seconds Press hold ENTER key for menu access Menu Displays A H Factory default displays shown A Flowrate and resettable tota...

Page 6: ...disable hysteresis feature L Sets auxiliary output pulse volume setpoint 0 0001 99999 sec 8 2 Set to 1 0000 factory default to enable totalizer function sec 8 2 M Sets auxiliary output pulse width 0...

Page 7: ...nds High 8 seconds also affects 4 to 20 mA output E Sets 4 mA output setpoint 4 mA and 20 mA setpoints are reversible F Sets 20 mA output setpoint 20 mA and 4 mA setpoints are reversible G Sets 4 mA c...

Page 8: ...ilicone rubber Weight Approximately 500 g 18 oz Display Type Microprocessor controlled air core meter movement and backlit alphanumeric 2 x 16 LCD Update rate Flow 1s totalizer 200 ms Contrast User se...

Page 9: ...96 mm 3 8 in RELAY 2 RELAY 1 ENTER 4 0 1 2 3 5 6 7 8 9 10 GPM Signet Monitor 92 x 92 mm 3 62 x 3 62 in Panel cutout Menu Parameters Display Description Range Factory Default A Flow rate and units Rese...

Page 10: ...max _Gallons E Total K Factor 0 0001 99999 60 000 F Relay 1 mode Relay 1 setpoint Low or High 0 0000 99999 Pulse 0 0001 99999 Low 10 000 GPM G Relay 1 Hysteresis Hysteresis volume 0 0000 99999 2 0000...

Page 11: ...l to D Display averaging Off 0 sec Low 4 sec High 8 sec Off E 4 mA setpoint Unlimited 0 0000 GPM F 20 mA setpoint Unlimited 100 00 GPM G 4 mA adjust 3 0 to 5 0 mA 4 00 mA H 20 mA adjust 19 to 21 mA 20...

Page 12: ...mall Reduce auxiliary output pulse width setting sec 9 2 M or increase pulse volume setting sec 9 2 L Must be between 0 0001 99999 Relay 1 Relay 2 or Auxiliary output AUX pulse volume setpoint must be...

Reviews: