Design and function
Instruction manual
34
5.2
Stroke limiter
In versions with the stroke limiter, stroke limiting is set to 90° ex works. This setting can be
changed if required. This allows the turning movement towards working position to be limited
to less than 90°, e.g. 45°.
In versions with the DA function, limiting is possible only towards the open position.
1 Covering
cap
2 Adjusting
screw
3 Locknut
5.2.1
Adjusting the stroke limiter
Check that there is no compressed air present
Unscrew the cover (1)
Use the control air to bring the actuator to working position
(DA function: CLOSED position)
Loosen the locknut (3)
Turn the adjusting screw (2) counter-clockwise (FC function) or clockwise (FO/DA function)
to obtain the desired stroke limitation
Actuator in rest position (DA function: OPEN position)
Test the stroke limiter. Repeat steps 3 to 6 if necessary
Tighten the locknut (3).
Screw on the covering cap (1)
NOTE
Summary of Contents for PA 21
Page 2: ......
Page 4: ...Betriebsanleitung 3...
Page 17: ...Technische Daten Betriebsanleitung 16 6 1 Drehmomentkennlinie PA11...
Page 18: ...Betriebsanleitung Technische Daten 17 6 2 Drehmomentkennlinie PA21...
Page 38: ...Instruction manual Technical specifications 37 6 1 Torque curve PA11...
Page 39: ...Technical specifications Instruction manual 38 6 2 Torque curve PA21...
Page 59: ...Donn es techniques Manuel d utilisation 58 6 1 Courbe caract ristique du couple PA11...
Page 60: ...Manuel d utilisation Donn es techniques 59 6 2 Courbe caract ristique du couple PA21...
Page 80: ...Manual de instrucciones Especificaciones t cnicas 79 6 1 Curva caracter stica del par PA11...
Page 81: ...Especificaciones t cnicas Manual de instrucciones 80 6 2 Curva caracter stica del par PA21...