Planungsunterlage TSA160 Datei 84338PuTSA160_GB_200999_.p65
*2) Door transition cable/provided by customer
4
3
3 3
1
1
1
4
4
8
2
2
4
3
3
4
3
4
3
4
3
4
3
4
3
4
4
3
*1)
*1)
*2)
Cable plan
double-leaf door incl. integrated closer control
Door drive 1
TSA 160 -IS
Cable plan double-leaf
TSA 160 - IS
230 V 50 Hz
Door drive 2
TSA 160
Intermediate
cover kit
2nd closing leaf
Main
switch
Emergeny
cut-off
switch
Power supply line
230V/50Hz
Fuse 16 A
Connected load
200 W
Allow cable to protrude at least 1 m out of the wal
Note:
Any warranty and service agreements will
be rejected if GEZE products are combined
with third-party products.
Cross-sections of cable
1
= NYM-J 3x1,5 mm²
2
= J-Y(ST)Y 2x4x0,6 mm
3
= J-Y(ST)Y 2x2x0,6 mm
4
= Cable conduit with Ø16 mm
Key-
operated
switch
inside
Contactor
inside
Programme
switch
Movement
detector
inside
(see sketch
A)
Cable outlet for
door drive
Movement
detector outside
(see sketch A)
Contactor
outside
Key-
operated
switch
outside
Sensor strips
and / or
and / or
Door opener
Lock switch contact
In addition:
Wiring diagram 70423/9-9750
Sketch A
For the installation and operation of the entire system the guidelines
(ZH1/494) for power-operated windows, doors and gates (issued by
the Association for Accident Prevention and Industrial Medicine,
53757 Sankt Augustin) have to be observed. In addition to this the
mounting and operating instructions as well as all other documents
refering to this product have to be observed.
Positioning of the movement
detectors
Sensor strips
1st closing leaf
*
1)
8-pole door transition cable incl.connecting box
(provided by GEZE)