TS 5000 ISM EFS
Mounting and securing
Connect free-swing door closer electrical
6.4
Fig.: 6.4.1
Connect customer-supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to terminal 3 and 4.
X
With connector box (A)
Lay customer supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to connector box (A) and
X
connect to + and – with luster terminal (Reverse battery protection, but no function).
Put the plug (B) into socket (C) at the closer and screw down.
X
In the case of concealed connection (D)
Lay customer supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to supply terminal (D) of
X
the closer (Reverse battery protection, but no function).
IMPORTANT
Following the guideline for hold-open systems by the DIBt (German Institution for Construction Technology) the
installation of a circuit breaker is compulsory, if door closers with free-swing function are used.
Connecting wire cable to trigger
6.5
Suspend ball on wire cable in trigger lever (
X
1.
).
Guide wire cable into funnel (
X
2.
).
Pull out wire cable at deflection pulley (
X
3.
).
Loosen clamping screw (
X
4.
).
Push wire cable through clamping piece (
X
5.
).
Tension wire cable (
X
6.
).
Push trigger slide up to stop (
X
7.
).
Tighten clamping screw (
X
8.
).
Shorten wire cable to an excess of 30-50 mm to outer edge of guide rail (
X
9.
).
30
-5
0
4.
8.
5.
9.
6.
7.
3.
2.
1.
GF
SF
Fig.: 6.5.1
GB 5