Slimdrive EMD/EMD-F
8
Description
3.3 Overview of the modes of operation
The following modes of operation can be set on the Slimdrive EMD:
à
Automatic
à
Exit only
à
Hold open
à
Night mode
à
OFF
Mode of operation
MPS/MPS-ST/
TPS*
DPS**
Explanatory notes
Key
Display
Automatic
a U
Door opens and closes again.
The inside and outside activation devices are active.
Refer also to Chapter 3.5.
à
Opening of 2 leaves
When the keys are pressed simultaneously, the mode
of operation changes between 1-leaf opening and
2-leaf opening.
à
Opening of 1 leaf
On the DPS the LED
is lit in 1-leaf operation.
Exit only
ls
Door only opens and closes if someone exits.
Only the inside activation devices are active.
Hold open
D O
Door remains open.
Night mode
Na
Door opens and closes only when activated using
the key switch The inside and outside activation
devices are inactive.
OFF
OFF
OFF
Of
Door is enabled and can be moved by hand. The
inside and outside activation devices are inactive.
*
Mechanical programme switch MPS/mechanical programme switch with integrated key switch MPS-ST/keypad
programme switch TPS
**
Display programme switch
3.4 Operating elements
The modes of operation can be set using the following operating elements:
à
Internal programme switch (20) on the drive unit (see chapter 3.4.1)
à
Mechanical programme switch MPS with/without integrated key switch (optional) (see chapter 3.4.2)
à
Display programme switch (optional) (see chapter 3.4.3)
à
Keypad programme switch (optional) (see chapter 3.4.4)
3.4.1 Internal programme switch
The mode of operation on the drive unit can be selected using the internal
programme switch (20). The switch position indicates the current mode
of operation:
à
Setting
II
a U
Automatic
à
Setting
0
N a
Night/Off
à
Setting
I
D O
Hold open
Summary of Contents for Slimdrive EMD-F-IS