GEZE Slimdrive EMD-F-IS Original Operating Instructions Download Page 11

Slimdrive EMD/EMD-F

11

Description

Additional door functions

Which switch/push button? 

What does the switch/push button do?

Emergency stop switch

The door stops immediately (in every mode of operation) 

and holds the position until the emergency stop switch 

is unlocked.

Key switch of the display programme switch

If a key switch is connected to the display programme 

switch, the operation of the display programme switch 

can be locked or released with it.

Activation device authorised (KB) (e.g. outside key switch) Door opens once and closes after the hold-open time. The 

set mode of operation is retained.

Switch function

The automated door can be activated using the switch 

function.

Normal switch function:

 

à

Switch contact opens the door and the door remains 

in the open position.

 

à

Switch contact closes the door.

Switch function with hold-open time:

 

à

Switch contact opens the door.

 

à

Switch contact closes the door or the door starts to close 

after the hold-open time.

Double push button

In the case of 2-leaf drives, a button with a double func-

tion can be connected via a push button for which param-

eters can be set. This means that 1-leaf or 2-leaf opening 

is possible by pressing the push button. 

If the push button is pressed once, only the active leaf 

opens and closes after the hold-open time has expired. 

If the button is pressed twice within 1.5 s, both leaves open 

and close after the double leaf hold-open time has expired.

Emergency lock

When the emergency lock is used, a switch can close the 

1- or 2-leaf system immediately. The doors close with the 

set force and without safety sensors and obstacle detec-

tion. There is an increased risk of injury.

WC control

The door opens after the elbow switch on the outside 

of the toilet has been pressed, and closes automatically 

after the set hold-open time has passed. 

When the push button is activated inside the toilet cabin, 

the system is switched to the exit only mode of operation, 

which means the outer push button no longer opens the 

door. At the same time, the lights indicate that the toilet 

is occupied. 

The electric strike is supplied with current, preventing 

manual opening of the door from outside. 

Activating the “inner” push button again or through man-

ual opening from inside, the WC function (exit only mode 

of operation) is cancelled and the drive switched back 

to the automatic mode of operation. 

The ‘occupied’ displays and lights go out.

Summary of Contents for Slimdrive EMD-F-IS

Page 1: ...for variants Slimdrive EMD 1 leaf 2 leaf Slimdrive EMD F 1 leaf 2 leaf Slimdrive EMD Invers 1 leaf 2 leaf Slimdrive EMD F IS Slimdrive EMD F R Slimdrive EMD F R IS Original operating instructions EN U...

Page 2: ...9 3 4 3 Display programme switch DPS option 9 3 4 4 Keypad programme switch TPS optional 10 3 5 Door in normal operation 10 4 Operation 12 4 1 Selecting the mode of operation 12 4 1 1 Selecting the m...

Page 3: ...o read the additional information carefully X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Product liability In c...

Page 4: ...he AUTO MATIC and EXIT ONLY modes of operation The door is opened automatically when the button is first pressed and closed again automatically when the button is pressed the second time The function...

Page 5: ...is in the closing position The electric strike remains switched off until the door has left the closing position Bolt feedback The bolt feedback function is a contact integrated in the lock latch that...

Page 6: ...nd are in a legible state Protect the programme switch against unauthorised access Danger of injury by sharp edges on the drive when removing the weather hood Danger of injury by parts hanging down Th...

Page 7: ...eaf transom installation 1 Drive unit 2 Link arm or lever 3 Smoke switch control unit 1 4 Outside contact sensor KA optional 5 Mechanical contact KB optional 6 Smoke switch 1 7 Contact sensor inside K...

Page 8: ...ted using the key switch The inside and outside activation devices are inactive OFF OFF OFF Of Door is enabled and can be moved by hand The inside and outside activation devices are inactive Mechanica...

Page 9: ...of operation is disabled if the key provided has been removed Mechanical programme switch MPS ST with integrated key switch 3 4 3 Display programme switch DPS option Can be connected additionally to t...

Page 10: ...n Closing safety sensor SIS is triggered while the door is closing The door immediately opens again or stops depending on the parameter setting Opening safety sensor SIO is triggered while door is ope...

Page 11: ...rs can be set This means that 1 leaf or 2 leaf opening is possible by pressing the push button If the push button is pressed once only the active leaf opens and closes after the hold open time has exp...

Page 12: ...switch optional In the programme settings I and II the display programme switch optional is used to display the mode of operation set and to output fault messages X X Set the internal programme switch...

Page 13: ...ng the display programme switch is only possible when the internal pro gramme switch 20 is set to the 0 position X X Touch the required mode of operation on the display pro gramme switch The mode of o...

Page 14: ...and keys The LED of the current operating state lights up When using a key switch X X Enable by operating the key switch once briefly Disable the operation of the keypad programme switch X X Activate...

Page 15: ...ke does not release X X Notify a service technician Fire alarm active Slimdrive EMD F only X X Activate reset button 19 Drive defective X X Notify a service technician Door does not close After 4 minu...

Page 16: ...e switch or control unit defective X X Notify a service technician Display of fault messages on the display programme switch Fault in the door system X X Note fault messages Up to 10 different fault m...

Page 17: ...to the maintenance display on the display programme switch Installation maintenance and repair work must be performed by experts authorised by GEZE If a dot appears on the bottom right hand part of th...

Page 18: ...lectrical connection values 230 V 50 Hz pursuant to DIN IEC 38 Connected load max 300 W Capacity rating 230 W Protection Mains connection 230 V on site 4 A to 16 A Current consumption for external dev...