Introduction

1.5  Terms

Term

Explanation

Hinge side

The side of the door where the hinges from which the door leaf is suspended are located. 

Usually that side of the door located in the opening direction.

Opposite hinge side

The side of the door facing the hinge side. Usually that side of the door located in the 

direction of closing movement.

Active leaf

The active leaf of a double leaf door. When the door is used, the active leaf must open 

as the first door leaf and close as the last door leaf.

Passive leaf

The secondary leaf of a double leaf door. When the door is used, the passive leaf may 

not open until the active leaf has left the closing position and must close again as the 

first door leaf.

Activation device inside (KI)

Push button, switch or movement detector for activating the drive unit.

The activation device is located within the room enclosed by the door.

Activation function in the AUTOMATIC and EXIT ONLY modes of operation.

The activation device does not have any function in the NIGHT/OFF mode of operation.

Activation device outside (KA) Push button, switch or movement detector for activating the drive unit.

The activation device is located outside the room enclosed by the door.

Activation function in the AUTOMATIC mode of operation. The activation device does 

not have any function in the EXIT ONLY and NIGHT/OFF modes of operation.

Activation device 

authorised (KB)

Access control function (for example key switch or card reader) used by authorised 

persons to activate the drive unit.

The activation function is active in the AUTOMATIC, EXIT ONLY and NIGHT/OFF modes 

of operation.

Activation device with current 

impulse function

Push button for opening and closing the door. Activation function only in the AUTO-

MATIC and EXIT ONLY modes of operation. The door is opened automatically when 

the button is first pressed and closed again automatically when the button is pressed 

the second time. The function can be activated during commissioning by parameter 

setting using the display programme switch, ST 220 or GEZEconnects. If the activation 

device is connected to the passive leaf control unit by means of the “current impulse” 

function, both door leaves open when activated, even when the passive leaf control 

system is deactivated.

Push&Go

When the door is pressed manually out of the closing position with an activated Push 

& Go function in the AUTOMATIC mode of operation, the door opens automatically 

as soon as a specific adjustable opening angle is exceeded.

Opening safety sensor (SIO)

Presence detector (e.g. active infrared light sensor) for protecting the swivelling range 

of the door in the opening direction. As a rule the sensor is located on the hinge side 

of the door on the door leaf.

Closing safety sensor (SIS)

Presence detector (for example active infrared light sensor) for protecting the swiv-

elling range of the door in the closing direction. As a rule the sensor is located on the 

opposite hinge side of the door leaf.

Emergency stop button

Self-locking switch with which immediate stopping of the drive unit can be triggered 

in case of danger. The drive unit remains in its current position until the user unlocks 

the emergency stop switch again, thus terminating the emergency stop situation.

Low-energy function

The Slimdrive EMD can be used as a low-energy drive.

In low-energy function the force needed for opening and closing the door is reduced 

to 67 N and the opening and closing time is reduced. This lowers the danger of a per-

son bumping into the moving leaf.

If people who are particularly vulnerable pass through the door, special measures must 

be taken to eliminate the contact hazard (e.g. use of open/closing safety sensors).

Summary of Contents for Slimdrive EMD-F-IS

Page 1: ...for variants Slimdrive EMD 1 leaf 2 leaf Slimdrive EMD F 1 leaf 2 leaf Slimdrive EMD Invers 1 leaf 2 leaf Slimdrive EMD F IS Slimdrive EMD F R Slimdrive EMD F R IS Original operating instructions EN U...

Page 2: ...9 3 4 3 Display programme switch DPS option 9 3 4 4 Keypad programme switch TPS optional 10 3 5 Door in normal operation 10 4 Operation 12 4 1 Selecting the mode of operation 12 4 1 1 Selecting the m...

Page 3: ...o read the additional information carefully X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Product liability In c...

Page 4: ...he AUTO MATIC and EXIT ONLY modes of operation The door is opened automatically when the button is first pressed and closed again automatically when the button is pressed the second time The function...

Page 5: ...is in the closing position The electric strike remains switched off until the door has left the closing position Bolt feedback The bolt feedback function is a contact integrated in the lock latch that...

Page 6: ...nd are in a legible state Protect the programme switch against unauthorised access Danger of injury by sharp edges on the drive when removing the weather hood Danger of injury by parts hanging down Th...

Page 7: ...eaf transom installation 1 Drive unit 2 Link arm or lever 3 Smoke switch control unit 1 4 Outside contact sensor KA optional 5 Mechanical contact KB optional 6 Smoke switch 1 7 Contact sensor inside K...

Page 8: ...ted using the key switch The inside and outside activation devices are inactive OFF OFF OFF Of Door is enabled and can be moved by hand The inside and outside activation devices are inactive Mechanica...

Page 9: ...of operation is disabled if the key provided has been removed Mechanical programme switch MPS ST with integrated key switch 3 4 3 Display programme switch DPS option Can be connected additionally to t...

Page 10: ...n Closing safety sensor SIS is triggered while the door is closing The door immediately opens again or stops depending on the parameter setting Opening safety sensor SIO is triggered while door is ope...

Page 11: ...rs can be set This means that 1 leaf or 2 leaf opening is possible by pressing the push button If the push button is pressed once only the active leaf opens and closes after the hold open time has exp...

Page 12: ...switch optional In the programme settings I and II the display programme switch optional is used to display the mode of operation set and to output fault messages X X Set the internal programme switch...

Page 13: ...ng the display programme switch is only possible when the internal pro gramme switch 20 is set to the 0 position X X Touch the required mode of operation on the display pro gramme switch The mode of o...

Page 14: ...and keys The LED of the current operating state lights up When using a key switch X X Enable by operating the key switch once briefly Disable the operation of the keypad programme switch X X Activate...

Page 15: ...ke does not release X X Notify a service technician Fire alarm active Slimdrive EMD F only X X Activate reset button 19 Drive defective X X Notify a service technician Door does not close After 4 minu...

Page 16: ...e switch or control unit defective X X Notify a service technician Display of fault messages on the display programme switch Fault in the door system X X Note fault messages Up to 10 different fault m...

Page 17: ...to the maintenance display on the display programme switch Installation maintenance and repair work must be performed by experts authorised by GEZE If a dot appears on the bottom right hand part of th...

Page 18: ...lectrical connection values 230 V 50 Hz pursuant to DIN IEC 38 Connected load max 300 W Capacity rating 230 W Protection Mains connection 230 V on site 4 A to 16 A Current consumption for external dev...

Page 19: ...Slimdrive EMD EMD F 19...

Page 20: ...nce fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office...

Reviews: