Slimdrive SL NT/SL NT-FR
8
Pre-installation
5.4 Fitting the left-hand module bearer
X
X
Fit the left-hand module bearer in compliance with the drawing.
5.5 Connecting the alarm contact to the locking device (optional)
X
X
Only screw the red locking pin (1) in again after the cover has been placed on.
X
X
Remove screws M2.3 x 10 on the feedback
switch (4) of the locking mechanism.
X
X
Place the alarm contact switch (3) on the
feedback switch (4).
X
X
Fix both switches in place on the locking
mechanism using M2.3 x 18 (2) screws and
spring washers.
X
X
Connect cable.
X
X
Shorten the switching flag of the alarm contact
switch.
5.6 Connecting the cable to the left-hand module bearer
X
X
Lay cable (2) to the toothed belt locking
(optional) (1), cut to size if necessary, strip and
attach the insulated wire-end ferrules.
X
X
Pull the plug (3) for the connection transformer
off the control unit.
X
X
Connect the three-core transformer cable to
the plug (3).
Leave the overall length of the transformer cable.