3.1  Intended use

The Slimdrive SL NT is designed solely for use

 

à

in dry rooms

 

à

in automatic door systems for horizontally moving door leaves

 

à

in entrances and interior areas of pedestrian traffic, in commercial plants and public areas

The Slimdrive SL NT and the Slimdrive SL NT-FR must not be used as fire or smoke control door drives.

The Slimdrive SL NT-FR is approved for use in emergency exits.

The Slimdrive SL NT must not be used as an emergency exit.

3.2  Safety instructions

 

à

The mandatory installation, maintenance and repair work must be performed by properly trained personnel 

authorised by GEZE.

 

à

The country-specific laws and regulations are to be observed during safety-related tests.

 

à

GEZE shall not be liable for injuries or damage resulting from unauthorised modification of the system, and 

the approval for use in emergency exits is voided when unauthorised changes are made (Slimdrive SL NT-FR).

 

à

GEZE is not liable if products from other manufacturers are used with GEZE equipment.

 

à

Furthermore, only original GEZE parts may be used for repair and maintenance work.

 

à

The connection to the power supply must be made by a professional electrician. Perform the power connec-

tion and equipment earth conductor test in accordance with VDE 0100 Part 610.

 

à

Use a customer-accessible 10-A overload cut-out as the line-side disconnecting device.

 

à

Protect the display programme switch against unauthorised access.

 

à

The detection field of the movement detector in the direction of the emergency exit must satisfy the AutSchR 

directive.

 

à

In compliance with Machine Directive 2006/42/EC, a risk analysis must be performed and the door system 

identified in accordance with CE Identification Directive 93/68/EEC before the door system is commissioned.

 

à

Observe the latest versions of guidelines, standards and country-specific regulations, in particular:

 

à

Technical rules for workplaces ASR A1.7 “doors and gates”

 

à

DIN 18650 “Building hardware – Automatic door systems”

 

à

VDE 0100, Part 610 “Erection of low-voltage installations”

 

à

AutSchR “Directive for automatic windows, doors and gates” (for Slimdrive SL NT-FR)

 

à

Accident-prevention regulations, especially BGV A1 “General regulations” and BGV A2 “Electrical systems 

and equipment”

 

à

DIN EN 60335-2-103 “Safety of electrical devices for home use and similar purposes; special requirements 

for drives for gates, doors and windows”

Summary of Contents for SL NT

Page 1: ...1 Slimdrive SL NT SL NT FR GB Installation instructions ...

Page 2: ...act to the locking device optional 8 5 6 Connecting the cable to the left hand module bearer 8 5 7 Fitting the right hand module bearer 9 5 8 Connecting the cable to the right hand module bearer 9 5 9 Pre positioning the pre mounted module bearer left and right 10 5 10 Pre mounting the roller carriage on the door leaf 10 6 Installation 12 6 1 Preparations on site 12 6 2 Installation 12 6 3 Commiss...

Page 3: ...echnical notes are emphasised in order to illustrate the correct operation Symbol Meaning means important note Information on avoiding material damage understanding a concept or optimising the processes means additional information X X Symbol for an action Here you have to do something Observe the sequence if there are several action steps 2 Product liability In accordance with the liability of ma...

Page 4: ...d maintenance work à à The connection to the power supply must be made by a professional electrician Perform the power connec tion and equipment earth conductor test in accordance with VDE 0100 Part 610 à à Use a customer accessible 10 A overload cut out as the line side disconnecting device à à Protect the display programme switch against unauthorised access à à The detection field of the movemen...

Page 5: ...bles etc can be drawn in by rotating parts à à Danger of injury through unsecured crushing impact drawing in or shearing spots à à Danger of injury by broken glass à à Danger of injury due to sharp edges in the drive à à Danger of injury during installation through freely moving parts 3 4 Inspection of the installed system Measures for security and prevention of pinching impact shearing or drawing...

Page 6: ... to change Only use the most recent version 4 2 Tool Tool Size Tape measure Marking pen Torque spanner Allen key 2 mm 2 5 mm 3 mm 4 mm 5 mm 6 mm Open ended spanner 8 mm 10 mm 13 mm 15 mm Ring spanner 8 mm 10 mm Screwdriver set Slotted up to 6 mm cross slot PH2 and PZ2 Torx bit T x 20 bit insert length at least 110 mm Pin punch 4 mm Side cutting pliers Crimping pliers for cables Wire stripper Multi...

Page 7: ...over to the required length 5 2 Fitting the brush X X Cut the brush 1 to the required length and insert into the running rail 2 5 3 Fitting the side plates X X Screw the sheet metal part 2 for securing the cover in the left hand and right hand side panels 3 X X Fit the side panels on the running rail 1 X X Place the stop buffers 4 on the far left and right of the running rail X X Tighten the setsc...

Page 8: ...alarm contact switch 3 on the feedback switch 4 X X Fix both switches in place on the locking mechanism using M2 3 x 18 2 screws and spring washers X X Connect cable X X Shorten the switching flag of the alarm contact switch 5 6 Connecting the cable to the left hand module bearer X X Lay cable 2 to the toothed belt locking optional 1 cut to size if necessary strip and attach the insulated wire end...

Page 9: ...g 5 8 Connecting the cable to the right hand module bearer 1 2 1 2 3 Slimdrive SL NT Slimdrive SL NT FR Slimdrive SL NT X X Lay rotary transducer cable 1 and motor connection cable 2 to the control unit X X Insert plug into the control unit Slimdrive SL NT FR X X Lay rotary transducer cable 1 motor connection cable 2 and motor connection cable of the second motor 3 to control unit X X Insert plug ...

Page 10: ...pply the stickers see the drive drawing à à Information plate enter the date of manufacture supplement digits of Classes 5 and 7 à à TÜV sticker à à Ü symbol for Slimdrive SL NT FR 5 10 Pre mounting the roller carriage on the door leaf For 1 leaf systems X X Slide the clamping plate 1 into the connect ing profile X X Slide the roller carriage 2 4 into the connecting profile 3 X X Secure both rolle...

Page 11: ...sing setscrews 5 The angled part 8 of the connection profile must be facing the main closing edge X X Mount the long driver 7 to the roller carriage 4 using 2 screws 1 and 2 leaf systems X X Mount the continuous roller carriage on the door leaves with the supporting brackets 8 X X Check whether the thread lies flush with the fixing holes X X If necessary loosen the supporting brackets on the door ...

Page 12: ...à à Evenness of the installation surface à à Evenness of the finished flooring à à Requirements of the cable plan 6 2 Installation 6 2 1 Mounting the drive Part 1 X X Remove the cover and the pre assembled module bearer Insert intermediate plates 1 X X Insert the intermediate plates 1 onto the rear of the running rail à à Upper row of drill holes for wall mounting à à Lower row of drill holes for ...

Page 13: ...ding to local conditions see installation diagram X X Install the floor guide 6 2 2 Fitting the door leaf WARNING Danger of injury by broken glass X X Always mount the door leaf together with another person WARNING Danger of crushing The door leaves are still unsecured and slide easily X X Make sure that the door leaves are not moved accidentally or by unauthorised persons X X Remove the roller ca...

Page 14: ...4 Installation Fitting the roller carriage into the running rail X X Insert roller carriage 2 into the running rail 1 as shown below X X Insert the mounting aid 3 as shown below to secure the roller carriage in the running rail ...

Page 15: ... door leaf and screwing it in place X X Move the roller carriage 1 into the door opening 4 X X Suspend the door leaf 3 on the height adjustment screws 6 X X Screw the door leaf in place using screws 7 Do not tighten screws yet X X Move the door leaf 3 to the side using the floor guide 5 X X Suspend the other door leaf 2 in the same way ...

Page 16: ...crews for height adjustment 1 X X Use the setting screw 2 ring spanner size 8 to adjust the height of the door leaves 2 leaf adjust the height of both door leaves X X Tighten the screws 1 and 3 X X Remove the mounting aid X X Move the door leaf into the open position X X Loosen the hexagon socket screws 4 of the stop buffer X X Push the stop buffer on the roller carriages X X Tighten the hexagon s...

Page 17: ... the motor X X Position the left module bearer 1 in such a way that it does not collide with the locking mechanism or the return pulley X X Screw the pre assembled module bearer left 1 and right 3 to the running rail 2 Tightening torques see drive diagram 6 2 6 Mounting the toothed belt X X Thread the toothed belt on the motor pulley and return pulley shorten if necessary X X Insert toothed belt e...

Page 18: ...the screw 1 X X Push the screwdriver into the gap and turn it until the toothed belt is tensioned X X Tighten the 2 screws 2 6 2 8 Setting the closing position for 2 leaf systems X X Push the door leaf to the closed position X X Fit second belt locks do not tighten screws 2 yet X X Use the long holes 1 to finely adjust the position in the direction of displacement X X Tighten the screws 2 when the...

Page 19: ...f necessary strip and attach the insulated wire end ferrules X X Connect the cable to the toothed belt locking optional see chapter 5 4 see wiring diagram X X Place cover 3 on control unit and lock in place The retention force of the cover can be increased by slightly bending the cover 6 2 11 Mounting the safety equipment X X Fit safety and actuation equipment X X Route cables properly in cable du...

Page 20: ...arer on the left see figure à à at the end of the running rail to earth the cover 6 2 15 Positioning the toothed belt locking optional 1 X X Close the door leaves X X Loosen the screws 1 at the toothed belt locking optional X X Align the locking device to the toothed belt X X Tighten screws 1 X X Lightly lubricate sliding surfaces The driver must not come into contact with the toothed belt locking...

Page 21: ...ectrician X X Perform the power connection and equipment earth conductor test in accordance with VDE 0100 Part 610 X X Attach the battery plug 1 at the control unit During maintenance work the battery must be disconnected from the control unit X X Check whether the battery cable is long enough attach extension cable if necessary X X Connect drive to 230 V mains 230 VAC 10 50 60 Hz and switch on th...

Page 22: ...r suspension piece 1 each into the upper and lower screw duct of the cover 2 X X Use 2 screws to secure the cover suspension piece 1 in the end section of the cover Installing the cover earthing 3 X X Knock the locating pin of the cover earthing 3 on the side of the earthing see chapter 6 2 14 approx 30 mm into the upper screw duct ...

Page 23: ...afety rope 3 at the suspension piece 2 of the side panels X X Mount the earthing wire of the cover earthing onto the tab connector of the earthing piece see chapter 6 2 14 X X Slide the hood onto the side panels until it latches in and ensure that it is also seated correctly in the area of the module bearer and cable holder X X Check the correct position of the cover safety rope 3 and the earthing...

Page 24: ... ATTENTION Danger of fatal injury due to electric shock X X The electrical system 230 V may only be connected and disconnected by a professional electrician X X Perform the power connection and equipment earth conductor test in accordance with VDE 0100 Part 610 CAUTION Danger of injury Persons can be injured when the cover is pivoted X X Always make sure two people handle covers over 4 m long CAUT...

Page 25: ...ng rail Check for cleanliness Clean the running rail if necessary Roller carriage Check the wear of the carrier rollers Remove the wear if necessary Check brushes Remove the roller carriage see chapter 8 2 Replace the brushes if necessary see chapter 8 3 Floor guide area Check for jarring free function Clean the floor guide area if necessary Floor guide area brushes Check for soiling and hardness ...

Page 26: ...necessary 8 2 Replacing the roller carriage X X Loosen the driver from the toothed belt lock X X Separate the driver from the roller carriage X X Secure the roller carriage against tilting using the leaf mounting aid see chapter 6 2 2 X X Loosen the hanger bolts on the roller carriage see chapter 6 2 2 X X Remove the door leaf X X Loosen the track supporting rollers X X Remove the leaf mounting ai...

Page 27: ... NT SL NT FR 27 Troubleshooting 8 5 Replacing fuse in transformer ATTENTION Danger of fatal injury due to electric shock X X Disconnect the system from the 230 V mains network on site before removing the PCB cover ...

Page 28: ... Hungary GEZE Hungary Kft Bartók Béla út 105 113 Budapest H 1115 Tel 36 1 481 4670 Fax 36 1 481 4671 E Mail office hungary geze com Iberia GEZE Iberia S R L Pol Ind El Pla C Comerc 2 22 Nave 12 08980 Sant Feliu de Llobregat Barcelona Tel 34 9 02 19 40 36 Fax 34 9 02 19 40 35 E Mail info geze es India GEZE India Private Ltd MF2 3 Guindy Industrial Estate Ekkattuthangal Chennai 600 097 Tamilnadu Tel...