Fundamental safety precautions
1.5 Abbreviations
HSK
Main closing edge
OKFF
Finished floor level
2
Fundamental safety precautions
To ensure personal safety, it is important to follow these safety instructions.
These instructions must be kept.
2.1 Intended use
The hook bolt locks A are only suitable for use
à
in dry rooms
à
in automatic door systems for horizontal door leaves
à
in entrances and interior areas of pedestrian traffic in commercial plants and public areas
The hook bolt locks must not be used in fire and smoke protection doors.
2.2 Safety notices
à
The mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
à
The country-specific laws and regulations are to be observed during safety-related tests.
à
If unauthorised changes are made to the system, GEZE cannot be held liable in any way whatsoever for any
resulting damage, and the approval for use in emergency exits ceases.
à
GEZE does not accept any warranty for combinations with third-party products.
à
Furthermore, only original GEZE parts may be used for repair and maintenance work.
à
The connection to the mains voltage must be made by a professional electrician. Perform the power connec-
tion and equipment earth conductor test in accordance with VDE 0100 Part 610.
à
Use an on-site 10-A overload cut-out as the line-side disconnecting device.
à
In compliance with Machinery Directive (2006/42/EC), a risk analysis must be performed and the door system
identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
à
Observe the current status of directives, standards and country-specific regulations, especially:
à
DIN 18650: 2010-06 “Building hardware– Powered pedestrian doors”
à
VDE 0100, Part 610: 2004-04 "Installing Electrical Power Systems with Nominal Voltages up to 1000 V"
à
DIN EN 16005: 2013-01 "Power operated pedestrian doorsets; safety in use; Requirements and test methods"
à
DIN EN 60335-1: 2012-10 “Safety of electrical devices for home use and similar purposes - Part 1: General
requirements IEC 60335-1: 2010, modified, German version EN 60335-1: 2012
à
DIN EN 60335-2-103: 2016-05 “Safety of electrical devices for home use and similar purposes - Part 2-103:
Special requirements for drives for gates, doors and windows. (IEC 60335-2-103: 2006, mo A1:2010,
modified); German version EN 60335-2-103: 2015
The product should be installed or incorporated in such a way that effortless access to the product is guaranteed
during any repairs and/or maintenance, and that any removal costs do not stand out of proportion to the value
of the product
2.3 Safety-conscious working
à
Secure workplace against unauthorised entry.
à
Watch the swivelling range of long system parts.
à
Never carry out work with a high safety risk (e.g. installing the drive, cover or door leaf) while alone.
à
Secure the cover/drive panels against falling.
à
Use only the cables prescribed in the cable plan provided. Cables must be shielded in compliance with the
wiring diagram.
à
Secure loose, internal drive cables with cable ties.
à
Before working on the electrical system:
à
Disconnect the drive from the 230/115 V mains and check to ensure that it is not supplied with power.
à
Disconnect the control unit from the 24 V rechargeable battery.
à
When an Uninterruptible Power Supply (UPS) is used, the system will still be under voltage even when
disconnected from the mains.
à
Always use insulated wire-end ferrules for wire cores.
à
Attach safety stickers to glass leaves.
à
Danger of injury with opened drive. Hair, clothing, cables, etc. can be drawn in by rotating parts.
Summary of Contents for Hook bolt Lock A
Page 1: ...Automatic Hook Bolt Lock A EN Installation instructions 186500 00 ...
Page 14: ...Hook bolt Lock A 14 Installation Closed position ...
Page 17: ...Hook bolt Lock A 17 Installation Closed position ...
Page 22: ...Hook bolt Lock A 22 Installation Closed position ...
Page 34: ...Hook bolt Lock A 34 Installation ...