Technical data
GC 342 safety sensor
36
16
Technical data
Technology
Laser scanner, time-of-flight measurement
Detection mode
Presence
Max. detection area
4 m (diagonal) with 2% reflectivity
(e.g. at W = 1.5 m
max. H = 3.7 m)
Opening angle
Door leaf safety: 90° / Pinch zone: 16°
angle resolution
Door leaf safety: 1.3° / Finger protection area: 0.2°
Typical min. object size
à
Door leaf safety
10 cm for 4 m (in Proportion to object distance)
à
Pinch zone
2 cm for 4 m (in Proportion to object distance)
Test body
700 mm × 300 mm × 200 mm (Reference body Ca in compliance
with EN 16005 and DIN 18650)
Characteristics of the transmitter
Infrared LaSER
Wavelength 905 nm; max. output pulse power 25 W;
Class 1
Power supply
12–24 V DC ± 15%
Power consumption
≤ 2 W
Response time
à
Door leaf safety
max. 50 ms
à
Pinch zone
max. 90 ms
Outputs
2 electronic relays (floating outputs - potential-free)
à
Max. switching
voltage
42 V aC/DC
à
Max. switching
current:
100 ma
LED signal
1 two-coloured LED Detection state / Initial state
Dimensions
142 mm (W) × 85 mm (H) × 33 mm (D) (mounting base + 7 mm)
Housing material
PC/aSa
Colour
Black - aluminium - White
Summary of Contents for GC 342
Page 1: ...EN Installation and operating instructions GC 342 safety sensor 167391 03 47 0159 V3 12 19...
Page 9: ...9 Installation GC 342 safety sensor 1 2 2 mm 5 mm 2 PZ2 3...
Page 11: ...11 Installation GC 342 safety sensor DIP ON 1 2 3 4 1 2 6 DIP ON 1 2 3 4 PZ1 1 2 7...
Page 19: ...19 Parameter setting GC 342 safety sensor SIO SIS SIS SIS SIS SIO SIS SIS SIS SIO SIS SIO...