9.2
DIP switches 2–4
1
ON
2 3 4
Parameter
Switch position
ON
OFF
DIP 2
Environment Standard
Critical
Switch to “Critical” if the environment
cause unwanted detections (min.
object size, immunity and uncovered
zones are increased)
DIP 3
Background
On
Off
Switch to “Off” if there is no back-
ground (glass floor, footbridge etc.)
DIP 4
Pinch zone
On *)
Off
Switch to “Off” if no secondary clos-
ing edge safety is required and ob-
jects can cause unwanted detection.
*) If DIP 4 is switched to ON, the input signal SIS on the drive must be set to “SIS REV”.
Carry out a risk analysis to check whether the environment requires additional
mechanical protection in the pinch zone.