background image

4

7

8

Range

 

à

Adjust according to requirement.

 

à

depends on the direction of movement, size and material/

type of object to be detected.

5

6

60 cm

60 cm

Output

Signal

sound

DIP

1 2

DIP

3

DIP

1 2 3

Colour of LED

Colour of LED

No detection

Detection

DIP

1 2 3

Off

Blue

Blue

Off

DIP

1 2 3

Blue

Green

DIP

1 2 3

Off

Green

DIP

1 2 3

Green

Off

DIP

1 2 3

Off

Off

DIP

1 2 3

Green

Red

DIP

1 2 3

Red

Green

DIP

1 2 3

1

2

Output mode

Control input

Connect the input to an external signal. 

When the contact is closed, the LED display lights up red.

Acoustic feedback

Pulse mode (NO):

Recommended for automatic

door applications

Pulse mode (NC)

Frequency mode

Toggle mode:

Recommended for switch

applications

On

Off

DIP

1 2

DIP

1 2

DIP

1 2

DIP

1 2

Output is still available. 

The input signal must be a potential-free contact

(no voltage).

Input

LED after DIP switch configuration

DIP

3

DIP

3

Summary of Contents for GC 307+

Page 1: ...e Recommended cable Braided cable up to 16 AWG 1 5 mm2 Adjustment of the detection field 10 cm is possible but the detec tion capacity of the sensor can then no longer be guaranteed The unit must be s...

Page 2: ...ontrol Slimdrive EMD Powerturn and sliding door drives Set the type of contact for KI and KA to normally open contact Follow the instructions for the drive Push button inside Push button outside Set P...

Page 3: ...DIP 1 2 3 Off Off DIP 1 2 3 Green Red DIP 1 2 3 Red Green DIP 1 2 3 1 2 Output mode Control input Connect the input to an external signal When the contact is closed the LED display lights up red Acou...

Page 4: ...rn the power supply off and on again After switch on the sensor can be unlocked within 1 minute without the access code being entered X Lock the sensor again at the end of the settings Saving the acce...

Page 5: ...olding time 0 0 5 s 1 2 3 4 5 1 s 2 s 3 s 4 s 5 s LED Colour of LED No detection Detection Off Blue To change these settings by remote control the DIP switches Colour of LED must be set to OFF 1 0 2 3...

Page 6: ...nal e g function WC control Optical and acoustic feedback in the event of external activation Colour of LED Red Colour according to DIP switch colour LED Red 1 0 2 3 4 5 6 7 Red Green Blue Yellow Red...

Page 7: ...Wired wrong X Check wiring and relay connection The door remains open The environment is influencing the functional ability of the sensor X Remove moving objects from near the sensor Wired wrong X Che...

Page 8: ...GEZE GmbH Reinhold V ster Stra e 21 29 71229 Leonberg Germany Tel 0049 7152 203 0 Fax 0049 7152 203 310 www geze com BEA no 47 0508 V1 06 2021...

Reviews: