GEZE GC 307+ Quick Start Manual Download Page 4

Open the GC 307+

Setting using the remote control

Operation

After unlocking, the red LED flashes 

and the sensor is accessible.

If the red LED flashes quickly after unlocking:

 

X

Enter the access code.

If the access code is not known:

 

X

Turn the power supply off and on again.

After switch-on the sensor can be unlocked 

within 1 minute without the access code being 

entered.

 

X

Lock the sensor again at the end of the 

settings.

Saving the access code
The access code (1 to 4 digits) is recommended for sensors which are close together.

Deleting the access code

Setting one or more parameters

 

Resetting to factory settings

                                                                                              Full reset

 

X

Enter the 

access code.

 

X

Select a parameter. 

 

Summary of Contents for GC 307+

Page 1: ...e Recommended cable Braided cable up to 16 AWG 1 5 mm2 Adjustment of the detection field 10 cm is possible but the detec tion capacity of the sensor can then no longer be guaranteed The unit must be s...

Page 2: ...ontrol Slimdrive EMD Powerturn and sliding door drives Set the type of contact for KI and KA to normally open contact Follow the instructions for the drive Push button inside Push button outside Set P...

Page 3: ...DIP 1 2 3 Off Off DIP 1 2 3 Green Red DIP 1 2 3 Red Green DIP 1 2 3 1 2 Output mode Control input Connect the input to an external signal When the contact is closed the LED display lights up red Acou...

Page 4: ...rn the power supply off and on again After switch on the sensor can be unlocked within 1 minute without the access code being entered X Lock the sensor again at the end of the settings Saving the acce...

Page 5: ...olding time 0 0 5 s 1 2 3 4 5 1 s 2 s 3 s 4 s 5 s LED Colour of LED No detection Detection Off Blue To change these settings by remote control the DIP switches Colour of LED must be set to OFF 1 0 2 3...

Page 6: ...nal e g function WC control Optical and acoustic feedback in the event of external activation Colour of LED Red Colour according to DIP switch colour LED Red 1 0 2 3 4 5 6 7 Red Green Blue Yellow Red...

Page 7: ...Wired wrong X Check wiring and relay connection The door remains open The environment is influencing the functional ability of the sensor X Remove moving objects from near the sensor Wired wrong X Che...