General Cleaning & Maintenance 

 

Maintenance of Drive Unit 

 

Aluminium Cover 
Wipe Clean with a damp cloth. DO NOT allow water to enter through the drive unit cover. 

 

Activation & Safety Sensors 
Ensure plastic lenses are clean & dust free. Wipe with a dry soft cloth if necessary. 

 

Preventative Maintenance 

 

GEZE strongly advise that a preventative maintenance programme is entered into, in line 
with the recommendations of BS 7036: Safety at powered doors for Pedestrian Use. 

 

An Authorized Technician to BS 7036 must carry out any servicing. 

 

Fabricated Doors / Screenwork only - See separate section for electrical drive unit covers.  

 

Atmospheric deposits, sulphurous acids, carbon dioxides and other chemicals in the air 
will discolour and tarnish all metalwork, and in time cause corrosion. Regular maintenance 
prevents atmospheric deposits building up and attacking the metals.   

 

Anodized Aluminium

 

Wash with mild soap and water or a mild detergent solution, rinse down with clean water 
and dry off with a soft cloth or chamois leather. Apply a liquid wax polish to protect the 
metal from the atmosphere. 

 

AVOID : Metal polish of any kind, abrasive cleaners, strong alkalines or acids, and the use 
of ammonia based cleaners for washing windows as they can cause staining of the 
surrounding framework. 

 

Recommended frequency - WEEKLY. 

 

P

 

 

olyester Powder Coated Aluminium. 

As with any organic coating, in order to retain the aesthetic properties, it is recommended 
that the coating be regularly maintained. Wash at intervals of not more than three months 
using a solution of warm water and mild detergent. (e.g. 5 % Teepol solution or mild 
washing up liquid.) All surfaces should be cleaned using a soft cloth or sponge but nothing 
harsher than a natural bristle brush. 

 

AVOID : Abrasive cleaners or cleaning solutions such as ketones, esters, or alcohols. 

 

Recommended frequency - THREE MONTHLY (depending on environment.)  

 

Polished or Satin Stainless Steel. 

 

Wash away grime and grit with luke warm soapy water or a mild detergent solution using 
a nailbrush for awkward crevices or corners. Repeat with clean water. Dry and polish with 
a soft duster or chamois leather. 

 

AVOID : Metal polishes, and all abrasives, toxic materials, acids, strong alkalines, nylon 
pads, wire wool. 

 

Recommended frequency - WEEKLY.  

 

Glass. 

 

Wash as often as possible with clean water and a chamois leather, scrim or squeegee, 
and dry off. The occasional application of a proprietary window cleaner or polish can be 
beneficial providing it does not contain ammonia. Advise may be given by a reputable 
window cleaning company.  

 

 

 

 

 

 

 

 

 

 

 

11 

                           

                                  

GEZE UK Ltd is part of the GEZE Worldwide Group of Companies 

Summary of Contents for EC Drive

Page 1: ...Slimdrive SC SCR Slimdrive SLT Slimdrive SL EC Drive Powerdrive Sliding Door Drive for Automatic Doors Operation Maintenance Manual GB GEZE UK Ltd is part of the GEZE Worldwide Group of Companies...

Page 2: ...y check list to be adhered to by the User Operational Switches 7 Detailed review of control switches Fault Codes 8 9 Detailed review of all fault codes Power Failure 10 Detailed review of power failur...

Page 3: ...t Powered Doors for Pedestrian Use Please adhere to the operating servicing and repair conditions specified by GEZE Servicing and repair work may only be carried out by properly trained GEZE personnel...

Page 4: ...meter Adjustable hold open time Automatic error detection Error indication at programme switch Audio signal in case of error Opening and closing speed individually adjustable Automatic adjustment of o...

Page 5: ...witched off and the door made safe Use of the door should not be re instated until an authorized technician has undertaken repairs Automatic Activation Devices Sensor Activation if fitted 1 Test Senso...

Page 6: ...ent should be subjected to systematic operational checks as often as is appropriate to the type of installation and its traffic flow This should be assessed with reference to the Hazard Analysis and R...

Page 7: ...same time Hold Open Mode Ho Whilst in this function the door will power open and be held permanently open Night Mode ni Whilst in this mode the drive unit is off All activation and safety devices are...

Page 8: ...0V voltage supply no voltage 10 No signal from the position indicator 12 Faulty motor 13 Safety sensor 1 contact closed 14 Flat battery 14V 15 Display program switch no signal 16 Lock not locking 17 L...

Page 9: ...ety sensor 2 contact closed 27 Safety sensor 1 contact open 28 Motor relay on main PCB defective 32 Tamper switch is activated 33 Second control sluice draught lobby 35 Pharmacy contact activated long...

Page 10: ...attery discharged No battery present Open unlock door manually and open door leaf by hand or battery Close close the door leaf by hand and manually lock the door discharged After power failure Door au...

Page 11: ...or washing windows as they can cause staining of the surrounding framework Recommended frequency WEEKLY Polyester Powder Coated Aluminium As with any organic coating in order to retain the aesthetic p...

Page 12: ...to suit individual site requirements The current BS7036 recommends that powered doors are serviced twice per year our Service Contracts are therefore based on this important recommendation A comprehe...

Reviews: