GEZE EC Drive Operation & Maintenance Manual Download Page 10

 

Power Failure

 

 
Power Failure 
 

If a power failure occurs, first check the fuse at the customer end. The presence of a 
battery determines whether the door opens or closes when the power fails. In most cases, 
the door will open in the event of power failure unless in Night mode (

ni

 
Battery present 

If the door is to be locked from the outside, operate the outside key switch 
(>4 seconds) until the programme switch lights up. Select 

ni

 by pressing 

the half moon symbol once: the door opens, closes and locks once. 

 

If the battery is discharged see “No battery present or battery discharged” 
 

 

 

No battery present   Open: unlock door manually and open door leaf by hand 
or battery 

Close: close the door leaf by hand and manually lock the door 

discharged  
 
After power failure 

Door automatically returns to the previously selected operating state 

 Or 
 

If the door is locked, it automatically changes to “Night” mode. 

 

Fire Alarm activation (if fitted) 
 

When the doors are in the “Automatic “setting they will power open and 
remain in the fully open position until the fire alarm has been reset. When 
the doors are in the “Night” position they will remain closed/locked so as 
not to compromise security 

 

 

Service Indicator 

 

 

When the service indicator LED is lit a annual service will be req`d 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

10

 

                                
 

                           

                                  

GEZE UK Ltd is part of the GEZE Worldwide Group of Companies 

Summary of Contents for EC Drive

Page 1: ...Slimdrive SC SCR Slimdrive SLT Slimdrive SL EC Drive Powerdrive Sliding Door Drive for Automatic Doors Operation Maintenance Manual GB GEZE UK Ltd is part of the GEZE Worldwide Group of Companies...

Page 2: ...y check list to be adhered to by the User Operational Switches 7 Detailed review of control switches Fault Codes 8 9 Detailed review of all fault codes Power Failure 10 Detailed review of power failur...

Page 3: ...t Powered Doors for Pedestrian Use Please adhere to the operating servicing and repair conditions specified by GEZE Servicing and repair work may only be carried out by properly trained GEZE personnel...

Page 4: ...meter Adjustable hold open time Automatic error detection Error indication at programme switch Audio signal in case of error Opening and closing speed individually adjustable Automatic adjustment of o...

Page 5: ...witched off and the door made safe Use of the door should not be re instated until an authorized technician has undertaken repairs Automatic Activation Devices Sensor Activation if fitted 1 Test Senso...

Page 6: ...ent should be subjected to systematic operational checks as often as is appropriate to the type of installation and its traffic flow This should be assessed with reference to the Hazard Analysis and R...

Page 7: ...same time Hold Open Mode Ho Whilst in this function the door will power open and be held permanently open Night Mode ni Whilst in this mode the drive unit is off All activation and safety devices are...

Page 8: ...0V voltage supply no voltage 10 No signal from the position indicator 12 Faulty motor 13 Safety sensor 1 contact closed 14 Flat battery 14V 15 Display program switch no signal 16 Lock not locking 17 L...

Page 9: ...ety sensor 2 contact closed 27 Safety sensor 1 contact open 28 Motor relay on main PCB defective 32 Tamper switch is activated 33 Second control sluice draught lobby 35 Pharmacy contact activated long...

Page 10: ...attery discharged No battery present Open unlock door manually and open door leaf by hand or battery Close close the door leaf by hand and manually lock the door discharged After power failure Door au...

Page 11: ...or washing windows as they can cause staining of the surrounding framework Recommended frequency WEEKLY Polyester Powder Coated Aluminium As with any organic coating in order to retain the aesthetic p...

Page 12: ...to suit individual site requirements The current BS7036 recommends that powered doors are serviced twice per year our Service Contracts are therefore based on this important recommendation A comprehe...