6.8 Functional test - Closing sequence control
Fig.: 6.8.1
X
Set the closing time for the secondary and the moving leaf (
1.
).
Recommended:
à
Closing time for moving leaf 5 seconds (from 90°).
à
Closing time for fixed leaf 5 seconds (from 90°).
X
Open fixed leaf by 90° and hold fixed (
2.
).
X
Open the moving leaf by 90° (
3.
).
X
Let the moving leaf close (
4.
).
The door should stop at an opening angle of >35°.
X
Now close the fixed leaf (
5.
).
The lock is released and the moving leaf closes.
6.9
24 V Mains connection
2
.
1.
Fig.: 6.9.1
X
Place the mains cable provided on site on the terminal (
1.
).
X
Shorten excess cable.
X
Connect cable to terminal (
2.
).
6.10 Adjusting electrical hold-open device
Moving leaf is shown.
1.
Fig.: 6.10.1
X
Open door leaf to desired hold-open angle and fix it there (
1.
).
X
Remove cable protection foils from guide (
2.
).
X
Loosen clamping screws of electrical hold-open device (
3.
).