www.geyserwise.co.za
13
Flange Type Elements
Tools needed:
Phillips screwdriver
Socket wrench
Your new element
Garden hose
Volt meter or circuit tester (to make sure power if off )
Be sure to use the same wattage, voltage, and flange style as your previous element.
1
Shut OFF electric power to water heater. See safety steps on page 6
2
Shut OFF cold water supply to the geyser, open the hot water faucet, attach a hose to the drain valve,
open the drain valve on the GEYSER and drain the water.
3
Remove access cover and fold back insulation.
4
Check wires with a Multi Meter before attempting to
remove the wires.
12
Inspect wiring. If corrosion is present on wiring, cut and strip wire 1/2” (only if wire is long enough). If corrosion
is still present, or wire is not long enough consult electrician for wire replacement and wire gauge selection.
Loose, corroded or faulty wiring connections can cause heat build-up or fire at wiring terminals.
13
Connect electric wires to element. Tighten screws.
14
Replace plastic terminal protector.
15
Replace insulation and access cover. Tank must be properly filled with water and free of air before applying
electric power to prevent element damage.
p
16
Turn ON electric power to water heater.
White DC
Blue DC
Black AC
Red AC
PTC Element
PV System Installers Guide
______________
Installation of the element