background image

7

About this manual

Gewiss

1.  About this manual

The purpose of this manual is to describe the JOINON electric vehicle charging stations and to provide appropriate 
information for their correct reception, installation, start-up, maintenance and operation.

1.1.  Scope of application

This manual is valid for the following charging stations:

JOINON Home

JOINON Home GW68101 (single phase)

JOINON Home GW68102 (three phase)

JOINON Home GW68101R (single phase)

JOINON Home GW68102R (three phase)

JOINON Parking

JOINON Parking GW68103 (single phase)

JOINON Parking GW68103R (single phase)

JOINON Parking GW68104C (three phase)

1.2.  Recipients

This document is intended for qualified personnel. 

The status of qualified personnel referred to in this manual will be, as a minimum, that which meets all the 
standards, regulations and laws regarding safety applicable to the tasks of installing and operating this unit.

It is recommended that this unit is installed by a professional installer.

1.3.  Symbols

This manual uses various symbols to emphasize and highlight certain texts. The general meanings are explained 
below.

General warning.

General information.

Electrical danger.

Read the section indicated.

Prohibition.

ABA2023IQM01_ - 7.55.4.412.2 - Installation and Operation Manual

EN

ES
FR
IT
HU

ABA2023IQM01_ - 7.55.4.494.0

ABA2023IQM01_ - 7.55.4.494.0

Summary of Contents for JOINON Home GW68101

Page 1: ...JOINON Home Parking Installation and Operation Manual Manual de instalación y uso Manuel d installation et usage Manuale d installazione e uso Telepítési és üzemeltetési kézikönyv ...

Page 2: ...ABA2023IQM01_ 7 55 4 494 0 ...

Page 3: ...3 Gewiss ABA2023IQM01_ 7 55 4 412 2 ABA2023IQM01_ 7 55 4 494 0 English EN Español ES Français FR Italiano IT Magyar HU ...

Page 4: ...mente y es posible que se produzcan cambios en siguientes ediciones El presente documento es susceptible de ser modificado La copie distribution ou utilisation de ce document ou de son contenu requiert une autorisation écrite Toute personne ne respectant pas cette condition sera passible de poursuites Tous les droits sont réservés y compris ceux qui découlent des droits de brevets ou d enregistrem...

Page 5: ...and Fastening 14 6 4 Opening the housing 14 7 Installing and connecting the unit 16 7 1 General requirements for installation 16 7 2 JOINON Home 17 7 2 1 Installing the unit 17 7 2 2 Connecting the power to the unit 18 7 3 JOINON Parking 20 7 3 1 Installing the unit 20 7 3 2 Connecting the power to the unit 21 8 Communication accessories 24 8 1 Local communication 24 8 1 1 JOINON Home 24 8 1 2 JOI...

Page 6: ...6 Contents Gewiss 12 1 Alarms 37 13 Waste handling 40 ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual ABA2023IQM01_ 7 55 4 494 0 ...

Page 7: ...ing GW68103R single phase JOINON Parking GW68104C three phase 1 2 Recipients This document is intended for qualified personnel The status of qualified personnel referred to in this manual will be as a minimum that which meets all the standards regulations and laws regarding safety applicable to the tasks of installing and operating this unit It is recommended that this unit is installed by a profe...

Page 8: ... applicable parts of harmonized standard EN 61851 Electric vehicle conductive charging system Electromagnetic Compatibility Directive These charging stations sufficiently comply with this directive by means of compliance with the applicable parts of harmonized standards EN 61000 6 1 Electromagnetic Compatibility Part 6 1 Generic standards Immunity for residential commercial and light industrial en...

Page 9: ...These charging stations can be purchased with different connection configurations relative to the client s needs The different available connectors are displayed below JOINON Home IEC 62196 2 Type 1 IEC 62196 2 Type 2 JOINON Parking IEC 62196 2 Type 2 ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 10: ...ing the door of the housing does not imply there is no voltage inside There is a risk of electric shock even after disconnecting all power sources from the system Only qualified personnel may open it following the instructions in this manual The entire manual must be read and understood in full prior to manipulating installing or operating the unit Following is a list of the basic obligatory safet...

Page 11: ...ir flow to reach the inside After all duly authorized handling check that the equipment is ready to start operation Only after this can it be connected following the instructions in the manual Do not touch boards or electronic components The more sensitive components can be damaged or destroyed by static electricity Do not disconnect or connect any terminal while the unit is operating Disconnect a...

Page 12: ...der to avoid damage In order to permit correct conservation of the charging stations you must not remove them from their original packaging until it is time to install them Deterioration of the packaging tears holes etc prevents the charging stations from being kept in optimum conditions before installation The manufacturer accepts no liability for any consequences arising from the deterioration o...

Page 13: ...2 Unpacking Correct handling of the charging stations is vitally important in order to Prevent damage to the packaging which enables them to be kept in optimum condition from shipping until they are installed Prevent the charging stations from receiving impacts and or falling which could deteriorate their mechanical features Avoid as far as possible vibrations which may cause subsequent malfunctio...

Page 14: ...mum surrounding air temperature 70 ºC Maximum relative humidity without condensation 95 It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature variations For this reason apart from the unit s own protection it is necessary to monitor these charging stations once they have been started up on sites where the conditions described above are not exp...

Page 15: ...15 Preparation for installing the unit Gewiss JOINON Home JOINON Parking ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 16: ...earing dielectric gloves and safety goggles approved for electrical hazards is required 7 1 General requirements for installation The environment of the unit must be appropriate and meet the guidelines described in Chapter 6 Preparation for installing the unit Additionally the parts used in the rest of the installation must be compatible with the unit and comply with the applicable legislation The...

Page 17: ... support on the wall using three fastening elements After carrying out this operation hang the unit from the support 2 Once it is mounted on the wall support install the hose support It can be installed at the bottom or to the side of the unit ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 18: ...uirements Connection specifications Connection type Single phase Number of conductors 2P E Nominal current up to 20 A Conductor maximum diameter 10 mm2 2 x 6 mm2 Connection process In order to connect the unit it is not necessary to open its front enclosure A window is located at the bottom of the unit to access the terminal block to which to make the connection Upon receiving the unit the cover o...

Page 19: ...ver 2 Connect the power cables to the terminal block as shown in the following figure The terminal blocks are clamp type Insert a flat head screwdriver to free it and insert the cable in the indicated hole Tighten it using the screwdriver T L N T Ground L Live N Neutral ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 20: ...he light turns to green The station is ready and awaits identification from the user in order to begin charging If the station identifies any operating anomaly the light turns red 7 3 JOINON Parking 7 3 1 Installing the unit 1 In order to mount the unit it is necessary to install a support on the wall using three fastening elements After carrying out this operation hang the unit from the support A...

Page 21: ...ase Number of conductors 2P E 3P N E Nominal current up to 32 A up to 32 A Conductor maximum diameter 10 mm2 2 x 6 mm2 Connection process In order to connect the unit it is not necessary to open its front enclosure A window is located at the bottom of the unit to access the terminal block to which to make the connection Upon receiving the unit the cover of this window is not installed 1 Insert the...

Page 22: ...le in the indicated hole Tighten it using the screwdriver T Ground L Live N Neutral T L N Single phase charging station In three phase stations the connection terminals are R phase R S phase S T phase T N neutral and PE ground 3 Screw the bottom cover onto the unit and tighten the packing glands in order to correctly secure the cable ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual ABA...

Page 23: ...the display will show an electric vehicle and the current time The station is ready and awaits identification from the user in order to begin charging If the station identifies any operating anomaly the light turns red and the type of incident is shown on the display see section 9 Operation ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 24: ... operate the communication accessories that enable remote communication see the Communication Accessory Manual for JOINON charging stations Los cable glands required for the communications cabling are not supplied with the charging station The required cable gland size is M16 8 1 Local communication 8 1 1 JOINON Home In JOINON Home communication is not included as standard and requires the install...

Page 25: ...ion of the communication ring First station Intermediate station Final station Communication ring A maximum of 10 stations can be interconnected 8 1 2 JOINON Parking 1 Connect the communication ring First station Final station Intermediate station ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 26: ...nication ring 2 Each control card has a jumper located next to the RJ45 connectors This jumper must be removed in all the intermediate stations of the communication ring and installed at the end stations ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual ABA2023IQM01_ 7 55 4 494 0 ...

Page 27: ...iting for a vehicle to be connected in order to proceed with charging Awaiting charge Flashing yellow INGEREV GARAGE Basic without RFID reader A user has selected the type of charge N or L using the key and the charging station is waiting for the user to connect their vehicle to this station INGEREV GARAGE Basic with RFID reader INGEREV GARAGE Wall INGEREV GARAGE One A user has identified a card u...

Page 28: ...h charging Awaiting charge Flashing yellow JOINON Home A user has selected the type of charge N or L using the key and the charging station is waiting for the user to connect their vehicle to this station JOINON Parking A user has identified a card using the reader and the charging station is waiting for the user to connect their vehicle to the station Charge Continuous blue A vehicle has been con...

Page 29: ...ied out turn the key clockwise to the L position The key can be left in the slot or it can be removed as required by the user Removing the key ensures that the charge process selection is not modified by third parties The front LEDs flash yellow when waiting for a vehicle to be connected It is possible to change the type of charge during the charging process by turning the key to the required posi...

Page 30: ...cle is connected to the station Starting the charge process 1 Check that the station is in the awaiting vehicle status showing the following two screens alternately 2 Press to access the language selection menu for the charging session Once the charging process ends the default language of the station will be enabled LANGUAGE ENGLISH LANGUAGE ENGLISH After accessing the language selection menu bro...

Page 31: ...ntify the card using the reader The station interrupts the electrical supply and unlocks the connector 7 Pull out the connector The station will return to the awaiting vehicle status Deferred charge For paired charge points the option to defer the charge process is possible In order to be able to select this type of charge the station must have the deferred charge option enabled The time selected ...

Page 32: ...the buttons or When the deferred charge option is highlighted press 4 A screen will be displayed with a flashing connector Connect the cable to the required electrical socket 5 Once the vehicle is connected to the station the deferred time selection screen will be displayed The preset time recorded on the card appears but can be changed to any required time SELECT STARTING TIME 21 SELECT STARTING ...

Page 33: ... information of each user session is displayed in the language configured on each card regardless of the default language configured in the station In the case of users with no language configured the station displays the information in the default language set 9 4 Incidents The incident can be caused by different reasons The charging station switches to incident status On the JOINON Parking stati...

Page 34: ...ent leak error code 0128 Depending on the model charging stations can have a DC current leak sensor for charging A leak in the current that causes the alarm to trigger originates from the electric vehicle that is being charged thus it is not an alarm for the recharging station rather the charge is stopped for safety reasons The maximum admissible limit for DC current leaks is exceeded Charging seq...

Page 35: ... out work on the unit interior qualified personnel only these instructions must be followed in the same order shown here to remove the voltage 10 1 Process for shutting down the unit The station shuts down when the power supply is disconnected ABA2023IQM01_ 7 55 4 412 2 Installation and Operation Manual EN ES FR IT HU ABA2023IQM01_ 7 55 4 494 0 ...

Page 36: ...ning from the company charging station operator and must be authorized to carry out such operations 11 2 Ground connection It is recommended to carry out an annual revision of the proper connection of the metal casing and other metal components on the outside of the charging station with the installation ground conductor Any worker who accesses the inside of the charging station must have the prop...

Page 37: ... is correct and check that there are no loose or incorrectly tightened cables Check the cabling of the auxiliary protection contact Interrupted supply error code 0002 Description This error can be caused by Absence of electricity grid The station restarts when the power is restored The protections have tripped Solution If the error persists after the electrical grid supply is restored check for th...

Page 38: ...ternal communication with the card reader Solution In JOINON Parking charging stations the RFID reader card is located on the back of the front cover Check the wiring of the RFID reader card RFID card reader DC current leak error code 0128 Description The maximum admissible limit for direct current leaks is exceeded while charging Depending on the model charging stations can have a direct current ...

Page 39: ...ent allowed during a maximum established time Solution The alarm will disappear upon completion of the charge session of the electric vehicle causing the alarm The keypad does not work JOINON Parking Description The charging station keypad does not respond Solution Make sure that the keypad cable is correctly inserted inside the unit and that there are no loose or incorrectly inserted cables in th...

Page 40: ... must be handled individually are 1 Liquid crystal displays 2 Printed circuit board cards Their location is shown in the following images 2 1 Waste that can be handled by conventional waste collection means Most of this waste is from the unit s packaging which must be properly separated and processed All the packaging can be delivered to a non hazardous waste management company In any event each p...

Reviews: