18
Installing and connecting the unit
Gewiss
In the event that it is not installed at the bottom of the unit, the support must be secured to the wall as
shown in the following image.
3. Check that the unit properly secured.
7.2.2. Connecting the power to the unit
Cabling requirements
The connection must meet certain requirements:
Connection specifications
Connection type
Single phase
Number of conductors
2P + E
Nominal current
up to 20 A
Conductor maximum diameter
10 mm
2
(2 x 6 mm
2
)
Connection process
In order to connect the unit it is not necessary to open its front enclosure. A window is located at the bottom of the
unit, to access the terminal block to which to make the connection.
Upon receiving the unit the cover of this window is not installed.