JOINON WALLBOX I-CON BASIC recharging unit for electric vehicles
46
2. Power supply inlet
3. Connect the power supply and signal cables according to the different models
L1 L2 L3 N
PE
L N
ALIMENTAZIONE
ELETTRONICA
ALIMENTAZIONE
PRINCIPALE
4. Once the electrical system is complete, the system is ready to be turned on.
If the station identifies a malfunction, the front status LED will turn red.
OPERATION AND CHARACTERISTICS
8.
Depending on the model, there are different ways of accessing the recharging service. The various operating
modes are explained below.
8.1.
AUTOSTART
AUTOSTART mode indicates that the recharging station is always available, without the need to iden-
tify the client by means of RFID or APP cards. The session begins as soon as the vehicle is connect-
ed to the recharging station. To end the charging session, stop it first on the vehicle (the method will
change depending on the vehicle model; we suggest you refer to the manual of your vehicle to find the
right method). The cable can now be removed from the vehicle, terminating the charging operation.
The station will now allow you to remove the plug.
It's also possible to select the recharging power by means of the selector on the side of the recharging station.
ELECTRONIC
POWER SUPPLY
MAIN
POWER SUPPLY
Some electric car models may have a minimum charge power limit.
To ensure that the minimum charge power selector on the I-CON AUTOSTART station is used correctly, please check this value in
your car instruction manual.
For example, the minimum power limit for the Renault Zoe® is about 1.8kW (8A) for a single-phase recharge and 8.5kW (13A)
for three-phase, so in the case of a 4.6kW I-CON AUTOSTART charging station, the selector will have to be set at 100% or 60%.
A 30% selector setting is lower than the minimum power permitted by the car, so the recharging session will not be started.