Group address Table on two levels:
KNX 2 Level Structure
Value DMX512
Chan-
nel Nr.
Sequence
Nr.
KNX-DMX Gate-
way Function
Detail
Main Groups
UG
0-15 (S1)
0-511
0..255 001-512 -
DPT 5.001 trans-
mits 1byte value
(Absolute value)
1 Byte value is stored
into the corresponding
DMX-Channel directly
0-15 (S1)
511-1023
0..255 001-512 -
DPT 1.001 value
transmission
When a 1 is received
the value stored in
sequence Nr. 8 is sent
to the correspond-
ing DMX-Channel
When a 0 is received
the DMX-Channel
is turned off.
0-15 (S1)
1024-1535
-7..+7 001-512 -
DPT 3.007 value
transmission
Relatively lighter or
darker dimming than
the current level
0-15 (S1)
1536-1543
0/1
ALL
0/7
DPT 1.001 value
transmission
Access saved
sequences
The selected sequence
values of all 512 chan-
nels are transmitted
on the DMX512 bus
0-15 (S1)
1544-1551
0/1
ALL
0/7
DPT 1.001 value
transmission
Save the new
sequence
All current DMX values
in channels 1-512 are
stored in the selected
sequence position
0-15 (S1)
1552
0/1
ALL
-
DPT 1.001 value
transmission
All channels
central on
All 512 channels
display 100% when
1 is transmitted, 0%
when 0 is transmitted
0-15 (S1)
1553
0..255 ALL
-
DPT 5.001 value
transmission
Repetition rate
parameters
Repetition rate
of 10msec
Value default 3
0-15 (S1)
1554
0..7
ALL
-
DPT 3.007 value
transmission
Set downward
dimming curve
Dim repitition value
Value Default 15=1%
0-15 (S1)
1555
0..7
ALL
-
DPT 3.007 value
transmission
Set upward
dimming curve
Dim repitition value
Value Default 15=1%
0-15 (S1)
1556
0/1
ALL
-
DPT 1.001 value
transmission
Deactivate auto-
matic dimming
Disables auto-
matic dimming
when value = 0