26
TECHNICAL DATA
Communication
KNX/EIB Bus
Power
By KNX/EIB bus, 29 V dc SELV
by control unit, 6 V dc
Bus wire
KNX/EIB TP1
Bus current consumption
8 mA max
Control elements
1 mini physical address programming key
Display elements
1 red physical address programming LED
Ambit of use
Indoors, dry places
Operating temperature
-5 ÷ +45 °C
Storage temperature
-25 ÷ +70 °C
Relative humidity
Max 93% (no condensation)
Bus connection
Slot in terminal, 2 pin Ø 1 mm
Connections to the
Signals: 8-pole mini DIN connector,
burglar alarm system
wire length 270 mm
Serial power: 0.5 mm
2
cable,
length 150 mm
Protection rating
IP20
Dimension (L x H x W)
38 x 38 x 13 mm
38 x 38 x 19 mm (with ribbing)
Reference standards
Low Voltage Directive 2006/95/EC
Electromagnetic compatibility directive 89/336 EC
EN50428, EN50090