19
Radon detector
5.1.2 Single installation
• Connect the power cable to an easily accessible, preferably separately pro
tected,
socket.
The device starts the self-test mode. The red alarm LED flashes once and a beep
sounds. After that, the green operating LED flashes for a maximum of 3 minutes
every second. During this time, the device determines the room air condition. If the
green LED is lit continuously, the device is ready for operation and monitors
the room air.
5.2 Test operation
The test operation ensures that the product works properly by briefly triggering
all audible and visual warning signals.
• Press the Test button to run the test mode or connect the device to a suitable
voltage
source.
If all LEDs flash briefly and a short warning tone sounds, the device is working
properly. The test operation ends automatically after a few seconds.
6 False alarm, defect
In case of improper operation or false alarm, the error LED lights up yellow and
a continuous tone sounds.
1. Are the environmental conditions deviating from the optimum operating range,
or are chemicals other than the gases referred to herein, such as those
described herein? Alcohol or acid present in high concentration in the room, test
the Radon detector in another room.
2. If none of the above situations occur, disconnect the device from the power
supply and reconnect it.
If a false alarm continues to be output, have the device replaced.
7 Maintenance, care, storage and transport
NOTICE
Material damage, false alarm
Gases and vapors from cleaning agents can lead to false alarms.
Detergents and chemicals can damage equipment.
►
Use only a dry and soft cloth for cleaning.
►
Do not use detergents and chemicals.
►
When not in use, store the product in a cool, dry, dust-protected
place out of the reach of children.
►
Store the original packaging for transport.
►
Regularly check the product for function by means of its test
button or by qualified electric / gas specialists.
8 Liability notice
Printing errors and changes to product, packaging or product documentation
the distributor also reserves the right without prior notice.
•
Please note the currently valid version of the guarantee conditions, which must
be requested in the current form under the contact details.
GB
BA_Radonmelder_001350.indd 19
26.03.2018 14:25:29
Summary of Contents for FMG 1350
Page 11: ...11 Radonmelder DE BA_Radonmelder_001350 indd 11 26 03 2018 14 25 28 ...
Page 21: ...21 Radon detector GB BA_Radonmelder_001350 indd 21 26 03 2018 14 25 29 ...
Page 31: ...31 Détecteur de radon FR BA_Radonmelder_001350 indd 31 26 03 2018 14 25 30 ...
Page 41: ...41 Rilevatori di gas radon IT BA_Radonmelder_001350 indd 41 26 03 2018 14 25 31 ...
Page 51: ...51 Czujnik radonu POL BA_Radonmelder_001350 indd 51 26 03 2018 14 25 32 ...
Page 61: ...61 Detektor radona SL BA_Radonmelder_001350 indd 61 26 03 2018 14 25 33 ...
Page 71: ...71 Detektor radónu SK BA_Radonmelder_001350 indd 71 26 03 2018 14 25 33 ...
Page 81: ...81 Detektor radonu CZ BA_Radonmelder_001350 indd 81 26 03 2018 14 25 34 ...
Page 91: ...91 Radon dedektörü TR BA_Radonmelder_001350 indd 91 26 03 2018 14 25 35 ...
Page 101: ...101 Radonjelző H BA_Radonmelder_001350 indd 101 26 03 2018 14 25 36 ...
Page 102: ...102 User manual BA_Radonmelder_001350 indd 102 26 03 2018 14 25 36 ...
Page 103: ...103 Radon detector BA_Radonmelder_001350 indd 103 26 03 2018 14 25 37 ...