How it works

The  motion  detector  works  based  on  passive  infrared 

technology. Via  a  PIR  sensor,  the  detector  notices  any  heat 

sources  moving  within  its  field  of  detection  and  switches 

on  automatically.    Static  heat  sources  do  not  trigger  it. The 

adjustable  twilight  switch  lets  you  choose  whether  you  have 

the motion detector working day and night or only when it is 

dark. The integrated timer also lets allows you adjust how long 

the light stays on.
Safety information

To be fitted by qualified electricians only, observing all 

standard national installation regulations.

No work to be carried out while live. Circuit trip switch 

must therefore be switched off.
Check to make sure the connecting cable is not live!

All  warranty  claims  will  be  null  and  void  in  the  event  of 

any  damage  or  loss  caused  by  failure  to  observe  these 

operating  instructions.  We  accept  no  liability  for  any 

consequential  losses  or  damage.  We  accept  no  liability 

for  any  personal  injury  or  material  damage  caused  by 

improper use or by failure to observe the safety advice. In such 

cases all warranty claims will be null and void. For reasons of 

safety  and  CE  approval,  no  unauthorised  conversion  and/or 

modification of the appliance is allowed.
Where to install

The  light  is  best  at  detecting  movement  when  this  is  at  right 

angles  to  the  motion  detector.  Motion  detectors  should 

therefore  always  be  set  up  so  that  likely  movement  is  not 

directly towards them. 
Installing the motion detector

Open  the  cover  of  the  terminal  box  according  to 

Fig. A  -  B

Install  the  motion  detector  according  to 

Fig. C - D. Connect 

the mains connection cable as shown in the circuit diagram in 

Fig. E. Connect the devices required, such as lights, via PE + 

N + L’. Replace the terminal box cover 

(Fig. G). Switch circuit 

protection back on.
Test mode/test run

This  test  mode/test  run  allows  you  to  individually  set  the 

desired field of detection.

Set the 

TIME controller to minimum and LUX to sun (fig. I). If 

the motion detector is connected via a separate switch, switch 

this on. The auto test then runs for 15 seconds during which 

time  the  connected  load  is  always  activated. When  the  load 

switches off, the test run starts. The load now switches on for 

approx. 5 seconds whenever motion is detected, regardless of 

the current lighting levels.  This time is reset each time motion is 

detected. The motion detector can be horizontally and vertically 

adjusted 

(fig. H).

Once the motion detector has been adjusted, further settings 

can be made.
Settings (fig. I)

SENS range 5 m – 12 m

TIME time setting for an activation time of approx. 10 sec. – 7 min.

LUX twilight switch approx. 5 – 2000 Lux

 

Recycling instructions

This device must not be disposed of with unsorted house-

hold waste. Owners of old devices are required by law to 

dispose of this device correctly. Contact your town council 

for further information. 

Motion detector ATHLET 180° LBC

Technical data

Field of detection  

180°

Range  

freely adjustable from approx. 5  to 12 m

Time adjustment  

freely adjustable from approx. 5 secs. to 7 mins

Twilight switch  

freely adjustable from approx. 5 to 2000 Lux

Mains connection 

230 V ~, 50 Hz

Switching capacity 

max. 300 W LEDs, max. 300 W energy saving lamp, 

 

max. 1200 W incandescent lamps

Protection type 

IP 44

Protection Class 

II

Recommended fitting height 

2.5 m

Troubleshooting – Practical tips

Problem 

Cause 

Remedy

Motion detector switches 

Field of detection setting 

Adjust field of detection 

the light on too late 

Movement from the front 

by turning the sensor

Motion detector fails to 

Motion detector is mounted too low 

Mount higher

achieve maximum range 

Difference in temperature between heat source and

  

surroundings is not big enough

Motion detector switches 

Constant thermal movement:  

light on constantly 

There are areas within detection range that are 

or when not necessary 

not supposed to be monitored, e.g. footpaths, roads, 

  

trees etc. Unexpected changes in heat sources

  

caused by storms, rain or fans.  

  

The influence of direct / indirect sunlight.

Fails to react to vehicles 

Vehicle has not warmed up

  

Engine area is very well insulated

Summary of Contents for ATHLET 16873

Page 1: ... International calls may vary GEV GmbH Heidehofweg 16 25499 Tangstedt Germany www gev de service gev de Hotline 49 0 180 59 58 555 www gev de Typ Bewegungsmelder ATHLET 180 LBC 16873 Weiß ATHLET 180 LBC 16880 Schwarz 150 mm 100 mm BA01175500 16WOA31 16873 16880 ...

Page 2: ...A B J H I 2 3 230 V G D E C F 2 5 m max 12 m SENS TIME LUX min 5 m 2 5 m 180ϒ 45ϒ 45ϒ PE ROT BLAU BRAUN L N L ...

Page 3: ...E auf minimum und LUX auf Sonne Abb I Falls der Bewegungsmelder über einen separaten Schalter angeschlossen ist schalten Sie ihn ein Es beginnt ein 15 Sekunden andauernder Selbsttest In dieser Zeit ist der angeschlossene Verbraucher dauernd eingeschaltet Wenn sich der Verbraucher ausschaltet beginnt der Gehtest Der Verbraucher schaltet sich jetzt unabhängig von der Umgebungshelligkeit bei jeder Be...

Page 4: ...ction Set the TIME controller to minimum and LUX to sun fig I If the motion detector is connected via a separate switch switch this on The auto test then runs for 15 seconds during which time the connected load is always activated When the load switches off the test run starts The load now switches on for approx 5 seconds whenever motion is detected regardless of the current lighting levels This t...

Page 5: ... TIME sur le mini et le bouton LUX sur soleil fig I Si le détecteur de mouvement est branché à l aide d un interrupteur séparé activer cet interrupteur Alors débute une phase de test automatique de 15 secondes Pendant ce délai l utilisateur raccordé est en marche permanente Lorsque l utilisateur s arrête le test de mouvement débute L utilisateur se met maintenant en marche pendant environ 5 second...

Page 6: ...ondo le proprie necessità il campo di rilevamento desiderato Impostare il regolatore TIME al minimo e LUX sul sole fig I Se il sensore di movimento è collegato tramite un interruttore se parato inserirlo Inizia un autotest di 15 secondi In questo peri odo di tempo l utenza collegata è inserita in modo continuo Se l utenza si disinserisce inizia la procedura di test Ora ad ogni movimento l utenza s...

Page 7: ...tosowanie zakresu obejmowania do indywidualnych potrzeb Regulator TIME ustawić na minimum a LUX na opcję słońce ilustr I Gdy detektor ruchu jest podłączony przez oddzielny przełącznik należy go włączyć Rozpocznie się 15 sekundowy ciągły test własny W tym czasie jest ciągle włączony podłączony odbiornik Gdy odbiornik się wyłączy rozpocznie się test ruchu Odbiornik włącza się teraz niezależnie od ja...

Page 8: ...15 14 ...

Reviews: