Installing and Starting the TRAPtest Software

Exit all open applications. Insert the TRAPtest CD in your CR-ROM drive, the installation
program starts automatically. Follow the on-screen prompts. The set-up program creates the
folder VPK 30 in the program group GESTRA.

Installing Software

TRAPtest Program

To start the program, click the START button on the Windows taskbar, point to Programs, and
then click TRAPtest. The main menu window appears.

To close the program, click the QUIT button in the main menu.

EXTRAS

The menu EXTRAS consists of the following items:

MANUFACTURER

ORGANIZE COMPANY

LANGUAGE

LIMIT VALUES

ABOUT

IMPORT

INTERFACE

TESTER

LOAD UPDATE

Under the menu item MANUFACTURER you can take down the particulars of the steam trap
manufacturers whose steam traps are installed in your plant. The entries are then listed in the
menu Test Objects and can be selected. We recommend to enter the corresponding data before
starting off with the first test object.

Under the menu item TESTER you can enter the name of your employees who are entrusted
with the task of checking the steam trap. The entries are then listed in the menu Test Objects
and can be selected. We recommend to enter the corresponding data before starting off with
the first test job.

Under the menu item LIMIT VALUES you can change the limit sound values preset by the
system (consultation with GESTRA recommended).

Under the menu item LANGUAGE you can select the language of your country.

Under the menu item INTERFACE you can select the port (COM 1, COM 2).

Under the menu item IMPORT you can import data records from a previous version (VKP 20).

Under the menu item ORGANIZE COMPANY you can enter the corporate names of the
operators or subdivisions of a company. The data entered here serve as key field to identify a
particular record and its occurence in the database.

Please note: When deleting an entry the related data record stored under this entry will
also be cleared completely.

The currently selected corporate names/subdivisions are, for instance, the headers of printouts
and windows.

Under the menu item LOAD UPDATE you can load the latest software version for the terminal
VKPN 30.

Under the menu item ABOUT you will find the address of the producer, the version number of
the TRAPtest program and the name of the currently selected company.

Menu Items of the TRAPtest Software

7

Summary of Contents for TRAPtest VKP 30

Page 1: ...TRAPtest VKP 30 Installation Instructions Steam Trap Monitoring Recording and Evaluation System ...

Page 2: ...tarting the TRAPtest Software Installing the software 7 Starting the TRAPtest program 7 Menu Items of the TRAPtest Software Extras 7 8 Test objects 8 Test instructions 8 Terminal 8 Online Documentation 8 Connecting and Commissioning the Terminal Connecting the terminal to a PC 9 Connecting the measuring transducer to a PC 9 Commissioning the terminal 9 10 Checking Steam Traps Preparation 11 Test 1...

Page 3: ...tion of safety equipment in accordance with regulations concerning electrical safety systems and first aid accident prevention have achieved a recognised level of competence appropriate to the installation and commissioning of this device The measuring transducer VKPS 30 must not make contact with any live part danger of electric shock Be careful when handling the equipment danger of injuries caus...

Page 4: ...nd diagnostic system detects and evaluates ultrasonic vibrations of steam traps which are caused by the flow of fluid steam through the trap These ultrasonic vibrations are sensed by pressing the tip of the measuring transducer VKPS 30 onto a specific trap body point which depends on the trap type and make The ultrasonic vibrations are converted by the measuring transducer into electrical pulses a...

Page 5: ...30 only for sensing ultrasonic vibrations at steam trap bodies Technical Data 5 System Requirements Windows 95 Windows 98 Windows NT CD ROM drive 80 MB of free hard disk space Test Duration 20 sec Hand Held Terminal VKPN 30 Plastic case with illuminated visual display and a 7 key membrane keypad Storage battery compartment at the underside of the device Two plug connections at the front face for c...

Page 6: ...torage batteries before replacing the back up battery data loss Be careful when taking apart the two housing halves Make sure not to damage the cable connection Slightly lift the bracket of the battery compartment and lever out the battery using a screwdriver 6 Measuring Transducer VKPS 30 Power is supplied to the measuring transducer by the storage batteries of the terminal Adaptor VKPA 30 The ad...

Page 7: ...g the steam trap The entries are then listed in the menu Test Objects and can be selected We recommend to enter the corresponding data before starting off with the first test job Under the menu item LIMIT VALUES you can change the limit sound values preset by the system consultation with GESTRA recommended Under the menu item LANGUAGE you can select the language of your country Under the menu item...

Page 8: ...evaluated as defective For each test instruction the system makes a statistical study of the number of traps checked not checked and to be checked as well as the number and percentage of defective traps HAND HELD TERMINAL In this menu the dialogue with and administration of the terminal takes place Test instructions are exported to the terminal and test results are imported from the terminal Test ...

Page 9: ... Then choose the selected PC port COM 1 or COM 2 in the TRAPtest on screen menu EXTRAS Interface and confirm your entry Connecting the Measuring Transducer to a PC To connect the measuring transducer VKPS 30 to the terminal plug the connecting cable of the measuring transducer into the right jack of the terminal VKPN 30 Commissioning the Terminal To start the terminal VKPN 30 press the START key f...

Page 10: ...out prior creation of data records and preparation of test instructions The test results are only stored up till the next measurement Under the menu item DATA EXCHANGE information is exchanged between the PC and the terminal The data stored in the terminal can be organized on the PC Test instructions are transferred from the PC to the terminal and test results are sent back from the terminal to th...

Page 11: ... WORD file Documentation doc from the directory Drive GESTRA VKP Proceed as described in the Online Documentation To check conventional thermostatic steam traps with bimetallic control or membrane regulators gently press the tip of the measuring transducer perpendicular to the trap surface onto the passage between cover and cover flange see illustrations Test To check float traps gently press the ...

Page 12: ...rder to be able to compare the results obtained and also to discover changes when repeating the test We hereby declare that the equipment VKP 30 conforms to the following European guidelines n LV guideline 73 23 EWG version 93 68 EWG n EMC guideline 89 336 EWG version 93 68 EWG which are based on the following harmonised standards n LV standard EN 60947 5 1 1991 n EMC standard EN 50 081 2 EN 50 08...

Page 13: ...810657 00 401 2001 GESTRA GmbH Bremen Printed in Germany Christian Schmidt 24 02 2000 ...

Reviews: